Chimney And Flue Ways; Troubleshooting - Parkray Double Consort 7 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Chimney and Flue ways

It is important that the chimney, flue ways and any connecting flue pipe are swept regularly. This
means at least once a year for smokeless fuels and at least twice a year for wood and other fuels. The
baffle will need to be removed from its supports in order to sweep the chimney (see assembly
instructions).
Only wire-centred sweeps' brushes fitted with a guide wheel should be used.
If it is not possible to sweep all parts of the chimney through the appliance, ensure there is adequate
access to cleaning doors.
If the stove is fitted in place of an open fire, then the chimney should be swept one month after
installation to clear any soot falls which may have occurred due to the difference in combustion between
the stove and the open fire.
Seasonal Use - if the appliance has been unused for a long period of time, such as during the spring and
summer months, a competent person should check the chimney for potential obstructions before lighting
the stove.
Gaskets
All gasket used on this appliance are produced from a heat resistant material called Manniglas. The
glass gasket will have to be replaced when a new piece of glass is fitted as the gaskets become brittle
after firing the stove. Over time you may also find that the gasket changes colour. This is due to a
reduction in the pigment used in the manufacture of the product and no cause for concern.

Troubleshooting

Fire will not burn
Check that:
1. The air inlet is not obstructed in any way.
2. Chimneys and flue ways are clear.
3. A suitable fuel is being used.
4. There is an adequate air supply into the room.
5. An extractor fan is not fitted in the same room as the stove.
6. Flue draught is above minimum level (see installation instructions).
Fire blazing out of control
Check that:
1. The doors are tightly closed.
2. The air controls are all in the closed position.
3. A suitable fuel is being used.
4. The glass retaining clips are not loose.
5. The door rope seals are in good condition
6. Flue draught is below maximum level (see installation instructions).