Driveline Lubrication - RHINO RX5 Operator's Manual

Table of Contents

Advertisement

DRIVELINE LUBRICATION

Grease Fittings are located on the Cross Assembly
of each U-Joint. Grease the U-Joint after each 8
hours of use. Figure MntP-R-0021. Do not force
grease through the Needle Cup Assemblies.
Grease the telescoping tubes after every 8 hours
use. To grease profile tube, disconnect drive from
PTO and pull halves apart. Pump grease into outer
profile tube and reinstall together. Lube Twist Collar
weekly with Multi-purpose gear oil, P/N 00786250
(Figure Mnt-R-0037).
The Driveline Integral Shields should not become dented or otherwise damaged. The Integral Shield Assembly
has a Nylon Bearing at each end and should turn freely. This nylon bearing should require lubrication every 40
hours. To remove the Integral Shields for replacement or repair, turn the three Nylon Nuts 1/4 turn in the Shield
Slots of the Cone and Tube and remove them. Slip the Shield Cone Assembly off inner section of the Driveline.
Install the new or repaired Shield on the Driveline. Place the split Nylon Bearing over the Driveline Housing of
Shaft against the Yoke and in the Bearing groove. Install shield over the Housing so the Nylon Bearing fits into
the Shield Bearing Retainer. Align a slot in the Shield Cone with one of the slots in the Shield. Put one of the
Nylon Nuts back in through the aligned slots and turn until it is perpendicular to the slots. Add the other two
Nylon Nuts.
Make certain that the Driveline Integral Shields are free to telescope and rotate around the
Driveline without binding.
RX5-RX6 02/10
© 2010 Alamo Group Inc.
MAINTENANCE
Maintenance Section 5-5

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Rx6

Table of Contents