Advertisement

Tracking Offset Check
Connection:
– RF Board (Component Side) –
oscilloscope
(DC range)
+
TP (VC)
IC101
TP (TE)
Procedure:
1. Connect the oscilloscope to TP (TE) and TP (VC) on the RF
board.
2. Put the set into play mode by loading the disc (YEDS-18).
[
AMS
3. Rotate the
.
>
mander, and check the traverse waveform*.
4. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to 0 V dc, and check this level.
* Traverse waveform: This is the tracking error wave form appears
when crossing the track.
Traverse waveform
A
0 V
B
A=B
traverse waveform
(100 track jump waveform)
]
dial on the wired remote com-
VOLT/DIV: 500 mV
TIME/DIV: 2 ms
Center: 0 V
CDX-454RF/454XRF