DCS 6000 Digital Conference System

System design

There are no settings to be done on the EX 6010
Extension Unit.
However it is important to observe, that the unit is
only repeating one of the chains on the CU 6105 or
CU 6110 Central Unit.
So when designing a system to incorporate EX
6010 Extension units, bear in mind, that as the EX
6010 Extension Unit is repeating only one of the
two outputs on CU 6105 or one of the four outputs

'Repeated chain' connection

Figure 0-A
Repeated Chain connection
When connecting the EX 6010 Extension Units to
the CU 6105 or CU 6110, the first EX is connected
to the 'Loop through' connector.
The next EX 6010 Extension units can be
connected to either the other 'Loop through'
connector or to one of the 'Repeated out'
on CU 6110, the max. number of languages
configured on the four outputs (1, 2, 3 and 4) is
totally max. 16.
If more languages are required, Interpreter sets
for those languages have to be connected either
to another EX 6010 Extension Unit, which is
connected to another of the four chains on the
CU 6110, or directly to one other of the four
chains on a CU 6110.
connectors. If using the 'Repeated' outputs two
more EX 6010 Extension units (or RP 6004
Repeaters) can be connected extending the
maximum cable length in one chain up to 680
m. The above schematic is showing the
connection using the ''Repeated chains'
connectors.