MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
I/O
76
VSS
-
77
EO2
O
78
EO1
O
79
TEST1
-
80
XOUT
O
Instrument :
SSG, OSC (5MHz), AC VOLTMETER, PWR SUPPLY, H/UNIT, CD-CH
No.
ITEM
INPUT SETTINGS
L/R Balance
CD-CH cignal off
1
Adj.
(Tr No.29 or Pause)
1. Ref.FM 1kHz 80dBµV
Moduration
2
Stereo, CD-CH Tr No.1
level Adj.
2. D.Cont Off MOD Lv:2
(Scope Setting Condition for L/R BAL. Adj.)
1. VOLTAGE RANGE : 5mV
2. TIME/DIV : 50µs
(Before Adj.)
Terminal name
Vss
Vss
NC
Not used (open)
Error out
Phase Detector Error output
NC
Not used (pull down to GND lines.)
X-out
X-tal
ADJUSTMENT
OUTPUT SETTINGS
Connect a
Oscilloscope
to Q301 Base.
Connect a
AC voltmeter
to Receiver PreOut
(After Adj.)
Fig. (a)
KCA-R71FM
Description
RECEIVER
ALIGNMENT
(MODULATOR)
POINTS
FREQ
88.3MHz
VR301
88.3MHz
VR302
* After Adj. The glue is applied to VR301, VR302.
Adjusted to be
min level point
Operation in HOLD
-
Hi-Z
Hi-Z
-
ALIGN FOR
FIG.
Min Level
(a)
Difference between
FM and a CD-CH
level is adjusted to
(-0.5±1.0dB).
5