[HUE Level Adjustment] (VI-40 board)
Mode
VIDEO Input
Signal
Color bar (S-VIDEO IN)
Measuring point
J1802 (OUTPUT)
Measuring equipment
Vector scope
Adjustment part
RV105
Specification value
Yellow phase 167 ± 4 deg
Adjustment Procedure:
(1) Connect on vector scope to the J1802.
(2) Press the S1707 (CAPTURE).
(3) Check yellow phase satisfies the specification value.
(4) If NG, press the S1708 (PICTURE) and lights on the D1733
(INPUT)
(5) A little adjust the RV105 and press the S1707.
(6) Repeat steps (2) to (5) until yellow phase satisfies the speci-
fication value.
167 ± 4 °
180 °
Yellow
Reference : B-Y Waveform (CL408)
90 °
Fig. 4-12
A
• If yellow phase is under 163 ° ,
extend the A level.
• If yellow phase is over 171 ° ,
shorten the A level.
Fig. 4-13
0 °
4-6