Foot Alignment; Connecting Stud Gun And Work Clamp To Power Source - Miller Electric 625 Owner's Manual

Miller electric owner's manual arc welder powcon arc stud 625
Hide thumbs Also See for 625:
Table of Contents

Advertisement

5-5. Foot Alignment

5-6. Connecting Stud Gun and Work Clamp to Power Source

3
3
2
1
1
4
1
2
4
3
4
5
.
5
Place a stud into the chuck and a ferrule into
the ferrule grip. The stud should sit perfectly
in the center of the ferrule. If not, loosen the
f lat head screws on the legs holding the foot.
Position the foot so the stud is perfectly
aligned in the ferrule. Retighten the flat head
screws.
Perform the following procedures when
connecting stud gun to power source:
2
.
Connecting Weld Cable and Work
Ground Cable
1
2
To connect to receptacle, align keyway, in-
sert connector, and turn clockwise (approx-
imately 1/2 turn).
Connect stud gun to black output terminal
labeled gun.
Connect work cable to black output terminal
labeled work.
Connecting Control Cable
3
4
Align key in end of control cable with key
way inside connector on front of power sup-
ply. Push the connectors together. Turn re-
taining nut on control cable clockwise.
When nut is snug the connection is com-
plete.
To remove, unscrew connector counter
clockwise.
Leg Screw
Foot
Ferrule
Ferrule Grip
Stud
Alignment of the foot is very important,
if the foot is not aligned properly it can
create bad welds in the form of hang−
ups.
Connect weld cable
Connect control cable
Use the same instructions provided if
connecting to an extension cable.
Flat
Keyway
Key
Keyway
Ref 802 385-A
OM-216 244 Page 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powcon arc stud 625