TECHNICAL GUIDE
Echelon
MODELS: FC9T-UP
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
UPFLOW TWO STAGE FURNACES
UP TO 94% AFUE
NATURAL GAS
40 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room
or garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented
using approved plastic type combustion air and vent piping.
All units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the
original purchaser; a 20-year limited warranty from original
installation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.
FEATURES
• Two stage heating operation includes:
• Provides increased comfort level & very quiet unit opera-
• Adjustable delay timer allows two stage operation with
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
• Integrated control module for reliable, economical opera-
• May be installed as either two-pipe (sealed combustion)
• Top intake & vent connection allows installation in narrow
• Electronic Hot Surface Ignition saves fuel cost with
• Induced combustion system with inshot main burners for
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• PSC -four speed, direct drive motor with large, quiet
• 24V, 40 VA control transformer and blower relay supplied
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-
ISO 9001
Certified Quality
Management System
• Timed on, adjustable off blower capability for maximum
• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance
• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
- Two stage gas valve
- Two stage inducer operation
tion
single stage thermostat
tion.
tion.
or single pipe vent (using indoor combustion air)
locations.
increased dependability and reliability.
quiet, efficient operation.
blower.
for add-on cooling.
grade stainless steel.
comfort.
or service.
246739-CTG-C-0407

Advertisement

Table of Contents
loading

Summary of Contents for Coleman FC9T-UP

  • Page 1 Lifetime limited warranty on both heat exchangers to the Echelon original purchaser; a 20-year limited warranty from original installation date to subsequent purchaser. MODELS: FC9T-UP 10-year warranty on the heat exchanger in commercial appli- cations. GAS-FIRED 5-year limited parts warranty.
  • Page 2: Cabinet And Duct Dimensions

    246739-CTG-C-0407 1-1/2” GAS PIPE ENTRY 1-1/2” GAS 7/8” JUNCTION PIPE ENTRY BOX HOLE T-STAT WIRING 7/8” JUNCTION 7/8” K.O. BOX HOLE CONDENSATE DRAIN 7/8” K.O. OPTIONAL RETURN AIR T-STAT WIRING CUT-OUT (either side) 13-7/8 7/8” K.O. FOR USE WITH EXTERNAL FILTER CONDENSATE FRAME DRAIN 7/8”...
  • Page 3: Electrical And Performance Data

    246739-CTG-C-0407 ELECTRICAL AND PERFORMANCE DATA Input Output Cabinet Air Temp. Nominal Airflow* Total Unit AFUE High/Low High/Low Width Rise Models Amps °F FC9T040A12UP11 40/26 38/24 1200 14-1/2 94.0 35 - 65 FC9T060B12UP11 60/39 56/36 1200 17-1/2 93.2 40 - 70 FC9T080B12UP11 80/52 75/49...
  • Page 4: Blower Performance Cfm

    246739-CTG-C-0407 BLOWER PERFORMANCE CFM Airflow with Bottom or One Side Retrun - without Filters (CFM) External Static Pressure, Inches W.C. Speed Models High 1395 1330 1265 1200 1120 1030 Med-High 1025 FC9T040A12UP11 Med-Low High 1650 1605 1570 1525 1465 1410 1350 1275 1170...
  • Page 5: Recommended Filter Sizes

    246739-CTG-C-0407 FILTER PERFORMANCE RECOMMENDED FILTER SIZES The airflow capacity data published in the “Blower Perfor- Input/Output Cabinet Side Return Bottom Return mance” table listed above represents blower performance BTU/H Size Filter in. Filter in. WITHOUT filters. To determine the approximate blower per- formance of the system, apply the filter drop value for the fil- 40/38 1200...
  • Page 6 246739-CTG-C-0407 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. FIGURE 1: Thermostat Chart - AC Unitary Products Group...
  • Page 7 246739-CTG-C-0407 FIGURE 2: Thermostat Chart - HP Unitary Products Group...
  • Page 8 APPLYING FILTER PRESSURE DROP TO PROPANE (LP) CONVERSION KIT - DETERMINE SYSTEM AIRFLOW 1NP0347 - All units This accessory conversion kit may be used to convert natural To determine the approximate airflow of the unit with a filter in gas units for propane (LP) operation. Conversions must be place, follow the steps below: made by qualified distributor or dealer personnel.

Table of Contents