D
S
ESIGN
PECIFICATIONS
E
LECTRICAL
Input Voltage:
Operating Current:
DC Transformers:
Laser Class:
E
NVIRONMENTAL
Operating Temperature:
Storage Temperature:
Humidity:
Light Levels:
Contaminants:
Ventilation:
Specifications subject to change without notice.
30
5.2VDC ± 0.25V
Power:
1.1 W
220 mA (270 IBM)
Class II; 5.2VDC@ 650 mA
CDRH: Class IIa; EN 60825-1:1994/A11:1996 Class 1
EMC:
FCC, ICES-003 & EN 55022 Class B
0°C to 40°C
(32°F to 104°F)
-40°C to 60°C
(-40°F to 140°F)
5% to 95% relative humidity, non-condensing
4840 LUX (450 foot candles)
Shock:
Designed to withstand 1 m (3.1') drops
Sealed to resist airborne particulate contaminants
None required