6. Writing the microprocessor software
6.1. Writing the main microprocessor software and monitor microprocessor software
(Main PWB: QPWBXF905WJZZ)
Adjustment item
1
Writing the software

7. Signal adjustment

7.1. LCD section adjustment [LCD module adjustment]
Adjustment item
1
Opposite bias adjustment
(LCD module adjustment
item)
7.2. Image adjustment
7.2.1 Device check
Before adjustment, check that the adjustment jig and signal source are set for Sharp LCD US.
Signal generator level adjustment check (Adjust to the standard value level.)
• 15K component signal:
• 33K component signal:
• Analog RGB:
7.2.2 Process mode
Adjustment point
Process mode
Adjustment conditions
Checker process
Checking the file version
Checking the USB memory
Adjustment conditions
Adjustment in the center
1) Enter the process mode using the process adjustment remote control.
position of the panel
2) Select [VCOM ADJ] using the Channel
3) Press the Enter key to check that the pattern for adjustment is displayed.
4) Make adjustment so that the flicker located in the center of the screen is mini-
5) If the optimum condition is obtained in step 4, press the Enter key to turn off the
CAUTION: * Make adjustment with no ANT signal (since the brightness is changed
[Adjustment position]
Y level:
0.714Vp-p± 0.02Vp-p (Pedestal to white)
0.7Vp-p ± 0.02Vp-p
PB/PR level:
0.7Vp-p ± 0.02Vp-p (Pedestal to white)
Y level:
0.7Vp-p ± 0.02Vp-p
PB/PR level:
0.7Vp-p ± 0.02Vp-p (Pedestal to white)
RGB level:
Adjustment conditions

Adjustment procedure

1) Connect the USB memory to J501 (TL514-517).
2) Set the PWB correctly and apply the specified voltage to it; then write the soft-
ware on it.
3) After confirming the completion of the writing operation, turn off the power.
4) File name
JAS_DTV_US_P101_Vx.xxx_AP.BIN
(x.xxx software version)
CAUTION: When the USB memory is not inserted or reading error occurs, nothing
is written.
Adjustment procedure
mized using the Volume +/- keys on the remote control.
pattern.
by the active backlight).
1/2
1/2
1/2
Adjustment procedure
Enter the process adjustment mode using the process adjustment remote control.
4 – 4
LC-60LE630U/U(A), LC-70LE735U
/
keys on the remote control.