Initial Setup; Operating Controls - Bunn Omni Installation & Operating Manual

Table of Contents

Advertisement

INITIAL SET-UP
1. Connect the brewer to the power source. The brewer will automatically begin to fi ll the tanks. After both tanks
are fi lled, the tank heaters will automatically turn on, one at a time. The dilution tank will heat fi rst, then the
brew tank. The tanks are fully heated when the BREWER READY indicator light is illuminated.
2. About 5 seconds after the brewer is connected to the power source, the LEFT/RIGHT LOW indicator lights
will illuminate. If a funnel is in place, the DISPOSE GROUNDS indicator will also be illuminated. Removing
the funnel for at least two seconds will reset this indicator.

OPERATING CONTROLS

1. BREWER READY INDICATOR
Indicates the water in the brew tank has reached the acceptable target temperature for brewing coffee. The
machine will not allow brewing until the indicator is illuminated. This is known as "brew Lockout" and cannot
be disabled. (Heating times are longer for 120V machines)
2. SERVICE INDICATOR
Indicates the machine has malfunctioned and requires service or clean. View the display screen for the actual
fault code. To reset any fault, remove the funnel and press both LEFT and RIGHT start switches. If the fault
returns, refer to the service decal (typically located on inside panel of door).
3. DISPOSE GROUNDS INDICATOR
Indicates that a brew or clean cycle is completed. Pull the funnel out and dump the used fi lter/grounds (or
Cleaning Packet). The indicator resets when the funnel is removed.
4. AUTOBREW ON INDICATOR
Indicates that the brewer is in the autobrew mode and will automatically start another brew cycle when a
reservoir reaches a low level. When brew cycle is completed, DISPOSE GROUNDS indicator will illuminate.
6
35352 121405

Advertisement

Table of Contents
loading

Table of Contents