Wiring Specifications - Mitsubishi Electric PUHZ-W50VHA Service Manual

Air to water
Hide thumbs Also See for PUHZ-W50VHA:
Table of Contents

Advertisement

6

WIRING SPECIFICATIONS

FIELD ELECTRICAL WIRING (power wiring specifications)
O
t u
o d
r o
u
t i n
m
d o
l e
Outdoor unit power supply
O
t u
o d
r o
u
t i n
C
c r i
t i u
r B
a e
e k
c r
p a
c a
O
t u
o d
r o
u
t i n
o p
w
r e
u s
p p
Interface unit/Flow temp. controller-Outdoor unit
Interface unit/Flow temp. controller-Outdoor unit earth
Remote controller-Interface unit/Flow temp. controller
Outdoor unit L-N (single)
Outdoor unit L1-N, L2-N, L3-N (3phase)
Interface unit/Flow temp. controller-Outdoor unit S1-S2 *3
Interface unit/Flow temp. controller-Outdoor unit S2-S3 *3
Remote controller-Interface unit/Flow temp. controller
*1.A breaker with at least 3.0 mm contact separation in each poles shall be provided. Use earth leakage breaker (NV).
*2.Max. 80 m
*3.The gures are NOT always against the ground.
S3 terminal has DC 24 V against S2 terminal. However between S3 and S1, these terminals are NOT electrically insulated by the transformer or other device.
Notes: 1. Wiring size must comply with the applicable local and national codes.
2. Power supply cables and the cables between Controller and Outdoor unit shall not be lighter than polychloroprene
sheathed fl exible cables.
(Design 60245 IEC 57)
3. Be sure to connect the cables between Controller and Outdoor unit directly to the units (no intermediate connections are
allowed).
Intermediate connections may result in communication errors. If water enters at the intermediate connection point, it may
cause insuffi cient insulation to ground or a poor electrical contact .
(If an intermediate connection is necessary, be sure to take measures to prevent water from entering the cables.)
4. Install an earth longer than other cables.
Power supply
A-Control
Outdoor Unit
Warning:
In case of A-control wiring,
there is high voltage potential on the S3 terminal caused by electrical circuit design that has no electrical insulation between
power line and communication signal line. Therefore, please turn off the main power supply when servicing. And do not touch the S1, S2, S3 terminals
when the power is energized. If isolator should be used between Interface unit/Flow temp. controller and outdoor unit, please use 3-pole type.
~/N (single), 50 Hz, 230 V ~/N (single), 50 Hz, 230 V ~/N (single), 50 Hz, 230 V 3N~ (3phase), 50 Hz, 400 V
y t i
1 *
y l
e ,
r a
h t
*2
*2
*3
*3
Isolator
S1
S2
S3
0 5
V
85 V
6 1
A
5 2
A
3
×
M
n i
1 .
5 .
3
×
M
n i
3 × 1.5 (polar)
3 × 1.5 (polar)
1 × Min. 1.5
1 × Min. 1.5
2 × 0.3 (Non-polar)
2 × 0.3 (Non-polar)
AC 230 V
AC 230 V
AC 230 V
AC 230 V
DC 24 V
DC 24 V
DC 12 V
DC 12 V
3 poles isolator
18
140 V
0 4
A
4 .
3
×
M
n i
6 .
3 × 1.5 (polar)
1 × Min. 1.5
2 × 0.3 (Non-polar)
AC 230 V
AC 230 V
DC 24 V
DC 12 V
S1
Interface unit/
S2
Flow temp. controller
S3
112 Y,140 Y
6 1
A
5
×
M
n i
1 .
5 .
3 × 1.5 (polar)
1 × Min. 1.5
2 × 0.3 (Non-polar)
AC 230 V
AC 230 V
DC 24 V
DC 12 V