UNIVERGE SV8100
Program 82 : Basic Hardware Setup for Extension
Level:
IN
Description
Use Program 82-11 : LCA Initial Data Setup to define the various timers for LCA
Packages.
Input Data
Item
Item
No.
01
Bounce Protect Time
02
HookFlash Start Time
03
HookFlash End Time
Feature Cross Reference
None
Programming Manual
Description
Specify a time for detection of a
valid off-Hook indication that is long
enough to prevent an unintentional
bounce of the receiver from being
detected as a new Off-Hook
indication from a Single Line
Telephone.
Specify the minimum hookflash
time from a Single Line Telephone
or analog Voice Mail system before
it is detected as the beginning of a
valid hookflash.
Specify the maximum hookflash
duration from a Single Line
Telephone to receive a second dial
tone.
Conditions
None
82-11 : LCA Initial Data Setup
Input
0 = No Setting
1~15 = 100ms~1.5sec
0 = 40ms
1~15 = 90ms~790ms
0 = HST+0ms
1~15 = HST+100ms~HST+1500ms
(HST=Hookflash Start Time)
Issue 1.0
Default
3
5
7
2 - 641