Connection of external dosing systems
20

5.2 Electrical connection of external dosing system

The power supply to the external dosing system must never be connected to the machine's incoming terminal
block or to the edge connectors on the I/O-board.

5.2.1 Machine with connectors

Connect the external dosing system to connections A and B on the machine.
Connect the signal cable to B and the power supply to A.
1
N
2
L
4
Ground
11
N
18
Program run
12
Signal 1
13
Signal 2
14
Signal 3
15
Signal 4
16
Signal 5
A
1
2
3
4
2
B
1
3
6
4
9
7
5