Meade RCX400TM Instruction Manual page 11

10", 12", 14” advanced ritchey-chrétien telescopes with autostar ii hand controller and digital front focus
Table of Contents

Advertisement

Definitions
Throughout this manual,
you will notice the terms
"Alt/Az," "Right
Ascension," and
"Declination." Alt/Az or
more properly, altitude-
azimuth (or altazimuth), is
frequently used to refer to
altitude or Declination (the
up-and-down vertical move-
ment of the telescope) and
azimuth or Right Ascension
(the side-to-side horizontal
movement of the tele-
scope). Right Ascension is
abbreviated as "R.A." and
Declination as "Dec."
Caution:
When loosening the Dec.
lock, be sure to support the
optical tube (19, Fig. 1a).
The weight of the tube
could cause the tube to
swing suddenly.
1#) in the unlocked position. Set the R.A. Lock to a "partially locked" position to create
a comfortable drag for the R.A. Slow Motion Control.
Caution: Do not operate the R.A. Slow Motion Control with the R.A. Lock
in the fully locked position, as such operation may result in damage to the
internal gear system and also cause you to lose alignment.
j
Optical Tube Assembly (OTA) Computer Control Panel (also see e):
H. USB Port: Provides 3 connections for USB 2.0 devices. This port is
typically used to connect to CCD cameras, such as Meade's LPI or
Deep Sky Imager. See
PC can control your
the Meade website (www.meade.com) to download the latest serial
commands and device pinouts.
J. Serial Port: Provides connection with a PC and for current and future
Meade accessories. Your PC can control your
serial commands. Go to the Meade website (www.meade.com) to
download the latest serial commands and device pinouts.
Important Note: Although both the Base Computer Control Panel and
the OTA Computer Control Panel include a serial port, only one may be
used at a time; you cannot plug into both ports at the same time.
K. Autoguider Port: Plug the optional autoguider into this port. See the
instruction sheet that came with your autoguider for more information.
Also see
OPTIONAL ACCESSORIES
L. Reticle Port: Plug the optional reticle eyepiece into this port. Control
the reticle through the AutoStar II menus. See
page 36. Also see
Note: See the instruction sheets that are included with the reticle and
the autoguider for more details.
M. Handbox (HBX) Port: Plug the AutoStar II coil cord into this port.
Important Note: Although both the Base Computer Control Panel and
the OTA Computer Control Panel include an HBX port, only one hand-
box maybe be plugged in at a time; you cannot plug handboxes into
both ports at the same time.
N. Smart Accessory Port: Provides connection for future Meade acces-
sories.
1)
GPS Receiver: Receives information transmitted from Global Positioning System
satellites. See page 25 for more information.
1!
Declination (Dec.) Setting Circle (on left fork arm): See
for detailed information.
1@
Mounting Base: Attach to the tripod base (see 2&). See page 16 for mounting
instructions.
1#
Right Ascension (R.A.) Lock: Controls the manual horizontal rotation of the
telescope. Turning the R.A. lock counterclockwise unlocks the telescope, enabling
it to be freely rotated by hand about the horizontal axis. Turning the R.A. lock
clockwise locks the telescope, prevents the telescope from being rotated manu-
ally, and engages the horizontal motor drive for AutoStar II operation.
1$
AutoStar II Handbox and Tiltable Holder: Controls all the electronic functions
of the telescope. See pages 13 - 15 for detailed information. You may have
noticed that there is no manual focus knob; all focus is achieved by
AutoStar handbox. Attach the holder to one of the handles (see f). Holds your
handbox in a convenient location.
1%
Right Fork Arm: The right side of the heavy-duty mount that holds the optical
tube securely in place (see g).
1^
Declination (Dec.) Slow-Motion Control: Make fine adjustments in
Declination(altitude) by turning this control with the Dec. Lock (see 1& below) in
the locked position. In order for this control to operate properly, power must be off.
1&
Dec. Lock: Controls the manual vertical movement of the telescope. Turning the
Dec. lock counterclockwise unlocks the telescope enabling it to be freely rotated
by hand about the vertical axis. Turning the Dec. lock clockwise (to a firm feel
OPTIONAL ACCESSORIES
400 telescope using serial commands. Go to
RCX
, pages 48 - 50.
, pages 48 - 50.
OPTIONAL ACCESSORIES
, pages 48 - 50.Your
400 telescope using
RCX
HOT BUTTON MENUS
, page 57,
APPENDIX A
u
sing the
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rcx400

Table of Contents