Provision For Ventilation; Technical Data - Hotpoint HUD 61K S Instructions For Installation And Use Manual

60cm dual fuel cooker
Table of Contents

Advertisement

Installation
Prior to installation, ensure that the local distribution
GB
conditions (nature of the gas and gas pressure) and
the adjustment conditions are compatible. The
adjustment conditions for this appliance are stated
on the data badge which is fitted on the back panel.
This appliance is not designed to be connected to a
combustion products evacuation device. It must be
installed and connected in accordance with current
installation regulations. particular attention should be
given to the relevant requirements regarding
ventilation.
MODEL NUMBERS
HUD61K,HUD61P,HUD61X,HUD61G
DSD60S,HAD60S,
Category II2H3+ (GB)
These models are set to burn NATURAL GAS (G20)
at 20 mbar but can be converted for use on BUTANE
(G30) at 28-30mbar or PROPANE (G31) at 37mbar
with the use of the LPG conversion kit that can be
obtained free of charge, if you contact our Genuine
Parts and Accessories department (see back page).
GAS SAFETY (INSTALLATION & USE)
REGULATIONS
It is the law that all gas appliances are installed by
competent persons in accordance with the current
edition of the above regulations. It is in your interest
and that of safety to ensure compliance with the law.
In the UK, Gas Safe registered installers work to
safe standards of practice. The cooker must also be
installed in accordance with BS 6172. Failure to
install the cooker correctly could invalidate the
warranty liability claims and could lead to
prosecution.
Burner
HOTPLATE
Front Left and Rear Right
HOTPLATE
Front Right and Rear Left
GRILL
MAIN OVEN
TOP OVEN
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
6
DSD 60P
G20 at 20mbar
HEAT INPUT
3.05 kW
2.0 kW
LOCATION
The cooker may be located in a kitchen, kitchen/
diner or a bed-sitting room, but not in a room
containing a bath or shower. The cooker must not be
installed in a bed-sitting room of less than 20m
When adjusted for use on Butane (G30) or Propane
(G31), the cooker must not be installed in a room or
internal space below ground level, e.g. in a
basement.

PROVISION FOR VENTILATION

The room containing the cooker should have an air
supply in accordance with BS 5440: Part 2.
The room must have an opening window or
equivalent; some rooms may also require a
permanent vent. If the room has a volume between 5
and 10m
, it will require an air vent of 50cm
3
effective area unless it has a door which opens
directly to outside. If the room has a volume of less
than 5m
, it will require an air vent of 100cm
3
effective area. If there are other fuel burning
appliances in the same room, BS 5440: Part 2
should be consulted to determine air vent
requirements.

TECHNICAL DATA

Gas connection
Pressure test point
Gas rate adjustment
Aeration adjustment
Electrical connection
G30 at 28-30mbar
INJECTOR
HEAT INPUT
116
3.0 kW (220g/h)
103
2.0 kW (145g/h)
2.2 / 2.4 kW
1.8 / 2.0 kW
1.7 / 1.9 kW
.
3
2
2
Rp ½ (½" BSP female)
Front left hotplate injector
None
None
6mm
twin and earth
2
230/240V a.c. 50Hz.
G31 at 37mbar
INJECTOR
86
70