Pc4020 Main Board Specifications Control Panel - DSC Maxsys PC4020 System Manual

Hide thumbs Also See for Maxsys PC4020:
Table of Contents

Advertisement

PC4020 MAIN BOARD
SPECIFICATIONS
Control Panel
16 zones
• 16 fully programmable supervised zones (EOL
resistor)
• Programmable for Double EOL resistors
Audible alarm output
• Bell output
700 mA, PTC 2.5 Amps, 12 V
11.6 - 12.6 V
- residential
DC
• Steady or pulsed output
Nonvolatile RAM (Internal Memory)
• Does not lose codes or system status on complete AC
and battery failure
Programmable output
• Transistor switch sinks 3 A to ground
• Programmable for 1 of 35 options
Powerful 1.5 amp regulated power supply
• 500 mA auxiliary supply, 11.6 - 12.6 V
(400 mA for UL Listed systems)
• Separate PTC for battery, auxiliary supply and bell
output
• Electronic shut down protection of the Combus
• Supervision for loss of AC power, low battery, electronic
shut down of modules
• Internal clock locked to AC power frequency or optional
crystal time base
Switched Auxiliary Supply Output
• Programmable for 1 of 35 options
• 11.6 - 12.6 V
DC
• 300 mA maximum
Battery
• 12 volt 4 Ah minimum rechargeable gel-cell or sealed
lead-acid battery
Transformer
• 16.5 VAC, 40 VA
- commercial
DC
DC
Output Voltage
Typically, with normal AC on and a fully charged battery,
the output voltage will be 13.8 V
battery discharging, the voltage will go below 10 volts and
then battery cutoff will occur preventing further discharge.
Devices that require power from the control panel should
be capable of operation over the voltage range of 10 to 14
V
.
DC
Remote Keypad
• Four wire (QUAD) hook-up
• Alphanumeric liquid crystal display
• Built-in piezoelectric buzzer
• Full annunciation of zones and system status
• Dimensions 5.5" x 4.5" x 1" deep (150 x 114 x 25 mm)
• Rated current draw of 55 mA
8
. With AC off and the
DC

Advertisement

Table of Contents
loading