Philips VR730/02 Service Manual page 8

Hide thumbs Also See for VR730/02:
Table of Contents

Advertisement

Power Supply Block Diagram
NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
HOT CIRCUIT. BE CAREFUL.
F001
T1.6A L 250V
AC001
HOT
1-9-19
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE T1.6AL/250V FUSE.
L003
D001 - D004
BRIDGE
LINE
RECTIFIER
FILTER
Q001
Q002
Q003
CAUTION !
Fixed voltage (or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
T001
Q051
2
12
Q052
13
Q057
4
14
Q058
15
16
11
7
17
6
18
IC001
ERROR
VOLTAGE DET
4
1
3
2
REG
Q004
(SHUNT REGULATOR)
MAIN CBA
Q053
P-ON+44V
P-ON-H
AL+15V/+12V
AL+9V
AL+12V
C-POW-SW
AL+5V
TIMER+5V
P-ON+5V
P-DOWN-L
Q054
Q056
COLD
1-9-20
HC470BLP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vr730/07Vr730/16Vr732/02Vr732/16Vr732/39Vr730/39

Table of Contents