Sign In
Upload
Manuals
Brands
GE Manuals
Security Sensors
VersaSafe VersaPoint Series
GE VersaSafe VersaPoint Series Manuals
Manuals and User Guides for GE VersaSafe VersaPoint Series. We have
1
GE VersaSafe VersaPoint Series manual available for free PDF download: User Manual
GE VersaSafe VersaPoint Series User Manual (124 pages)
SAFETY LOGIC MODUL , SAFE OUTPUT 24VDC, 8PT
Brand:
GE
| Category:
Security Sensors
| Size: 1.58 MB
Table of Contents
Table of Contents
7
1 For Your Safety
11
General Safety Notes
11
Electrical Safety
12
Safety of the Machine or System
13
Safety for Starting Applications
14
Directives and Standards
14
Correct Usage
14
Documentation
15
Abbreviations Used
15
2 Product Description
17
Note about the System Description
17
Brief Description of the Safety Module
17
Structure of the Safety Module
18
Housing Dimensions
18
Safe Digital Outputs
19
Connection Options for Actuators Depending on the Parameterization
21
Local Diagnostic and Status Indicators
22
Safe State
24
Operating State
24
Error Detection in I/O Devices
24
Device Errors
25
Parameterization Errors
25
Process Data Words
26
Programming Data/Configuration Data
26
Local Bus
26
Other Bus Systems or Networks
26
3 Versapoint Potential and Data Routing, and Versapoint Connectors
27
Versapoint Potential and Data Routing
27
Supply Voltage U
27
Supply Voltage U M
28
Terminal Point Assignment
29
4 Assembly, Removal, and Electrical Installation
33
Assembly and Removal
33
Unpacking the Module
33
General
33
Setting the DIP Switches
34
Assembly and Removal of the Safety Module
36
Electrical Installation
38
Electrical Installation of the Versapoint Station
38
Electrical Installation of the Safety Module
38
5 Parameterization of the Safety Module
41
Parameterization of the Safety Module in a Versasafe System
41
Parameterization of the Safe Outputs
42
Behavior of the Outputs in the Event of Enabled Switch-Off Delay for Stop Category 1
44
6 Connection Examples for Safe Outputs
45
Explanation of the Examples
45
Notes on the Protective Circuit for External Relays/Contactors (Free Running Circuit)
46
Measures Required to Achieve a Specific Safety Integrity Level
47
Single-Channel Assignment of Safe Outputs
49
Two-Channel Assignment of Safe Outputs
52
7 Startup and Validation
55
Initial Startup
55
Restart after Replacing a Safety Module
57
Replacing a Safety Module
57
Restart
57
Validation
57
8 Errors: Messages and Removal
59
Safe Digital Output Errors
62
Supply Voltage Errors
63
General Errors
63
Parameterization Errors
64
Connection Errors to Satellites
65
Acknowledging an Error
66
9 Maintenance, Repair, Decommissioning, and Disposal
67
Maintenance
67
Repair
67
Decommissioning and Disposal
67
10 Technical Data and Ordering Data
69
System Data
69
Versapoint
69
Versasafe System
69
Ic220Sdl953
69
Conformance with EMC Directive
74
Ordering Data
75
Ordering Data: Safety Module
75
Ordering Data: Accessories
75
Ordering Data: Software
75
Ordering Data: Documentation
75
A Appendix: Versasafe System
77
A 1 the Versasafe System
77
A 1.1 Versasafe Technology - Maximum Flexibility and Safety
77
A 1.2 Overview of Versasafe System Features
78
A 1.3 Differences in Versasafe Systems Dependent Upon Which Module with Integrated Safety Logic Is Used
78
A 2 System Topology
80
A 2.1 General Topology
80
A 2.2 Network and Controller Requirements
81
A 2.3 Safe Input and Output Devices
81
A 3 Versasafe Address Assignment
82
Operating Modes and Setting the DIP Switches in the Versasafe System
86
Module Switch Positions
86
A 4.2 Versasafe Multiplexer Mode
87
A 5 Process Image
89
A 5.1 Structure of the Process Image
89
A 5.2 Description of the Registers
93
A 6 Implementation of Data Flow between the Standard Controller and the Safety Modules
98
A 6.1 Implementation of Data Flow with a Function Block
98
A 6.2 Implementation of Data Flow Without a Function Block
98
A 7 Enable Principle
98
A 8 Diagnostics
100
A 8.1 Error Detection in I/O Devices
100
A 8.2 Detection of Device Errors
101
A 8.3 Acknowledgment of Error Messages for Satellites
101
A 9 Configuration, Parameterization, and Download
102
A 9.1 Configuration and Parameterization Using the Versaconf Safety Tool
102
A 9.2 Downloading the Configuration and Parameter Data Record Following Power up
103
A 10 Safe State
103
A 11 Time Response in the Versasafe System
104
A 11.1 Typical Response Time
104
Shutdown Times
105
A 11.2 Shutdown Times
105
A 12 Achievable Safety Depending on the Modules Used
106
A 13 Behavior in the Event of an Error
107
A 13.1 Critical System or Device Errors
107
A 13.2 Parameterization or Configuration Errors
108
A 13.3 Communication Errors
108
A 13.4 I/O Errors
108
A 14 Startup and Restart
109
A 14.1 Startup/Restart Following Power up
109
A 14.2 Restart after Triggering a Safety Function
109
A 15 Memory Sizes for the Safety Logic
109
B Appendix: Checklists
111
B 1 Checklists for the Versasafe System
112
B 1.1 Planning
112
B 1.2 Configuration and Parameterization
114
B 1.3 Startup
115
B 1.4 Safety Functions
116
B 1.5 Validation
117
B 2 Checklists for the IC220SDL953 Module
118
B 2.1 Planning
118
Assembly and Electrical Installation
119
B 2.3 Startup
120
B 2.4 Validation
121
C Index
123
Advertisement
Advertisement
Related Products
GE VE1012 Series
GE VE1012AM
GE VE1016 Series
GE VE1100 Series
GE VERTICAL ZONELINE 2010
GE VersaMax
GE VersaMax PLC
GE VersaMax I
GE Versana Essential
GE VeriDri
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL