ABB RELION REL650 Manuals
Manuals and User Guides for ABB RELION REL650. We have
3
ABB RELION REL650 manuals available for free PDF download: Commissioning Manual, Operation Manual
ABB RELION REL650 Commissioning Manual (152 pages)
Brand:
ABB
| Category:
Protection Device
| Size: 3.73 MB
Table of Contents
Table of Contents
7
Introduction
15
This Manual
15
Intended Audience
15
Product Documentation
16
Product Documentation Set
16
Document Revision History
17
Related Documents
17
Document Symbols and Conventions
18
Symbols
18
Document Conventions
19
IEC 61850 Edition 1 / Edition 2 Mapping
19
Safety Information
23
Symbols on the Product
23
Warnings
23
Caution Signs
24
Note Signs
25
Available Functions
27
Main Protection Functions
27
Back-Up Protection Functions
27
Control and Monitoring Functions
28
Communication
30
Basic IED Functions
31
Starting up
35
Factory and Site Acceptance Testing
35
Commissioning Checklist
35
Checking the Power Supply
36
Energizing the IED
36
Checking the IED Operation
36
IED Start-Up Sequence
36
Setting up Communication between PCM600 and the IED
37
Writing an Application Configuration to the IED
42
Checking CT Circuits
42
Checking VT Circuits
43
Using the RTXP Test Switch
43
Checking the Binary Input/Output Circuits
44
Binary Input Circuits
44
Binary Output Circuits
44
Checking Optical Connections
44
Configuring the IED and Changing Settings
45
Overview
45
Configuring Analog CT Inputs
45
Supervision of Input/Output Modules
46
Establishing Connection and Verifying the SPA/IEC Communication
47
Entering Settings
47
Entering SPA Settings
47
Entering IEC Settings
47
Verifying the Communication
48
Verifying SPA Communication
48
Verifying IEC Communication
48
Fibre Optic Loop
48
Optical Budget Calculation for Serial Communication with SPA/IEC
49
Establishing Connection and Verifying the LON Communication
51
Communication Via the Rear Ports
51
LON Communication
51
The LON Protocol
52
Hardware and Software Modules
52
Optical Budget Calculation for Serial Communication with LON
54
Establishing Connection and Verifying the IEC 61850 Communication
55
Overview
55
Setting the Station Communication
55
Verifying the Communication
55
Testing IED Operation
57
Preparing for Test
57
Requirements
57
Preparing the IED to Verify Settings
58
Activating the Test Mode
59
Preparing the Connection to the Test Equipment
59
Connecting the Test Equipment to the IED
60
Releasing the Function to be Tested
60
Verifying Analog Primary and Secondary Measurement
61
Testing the Protection Functionality
61
Forcing of Binary Input/Output Signals for Testing
62
Forcing Concept
62
How to Enable Forcing
62
Enable Forcing by Using LHMI
62
Enable Forcing Using TESTMODE Function Block
62
How to Change Binary Input/Output Signals Using Forcing
63
Forcing by Using LHMI
63
Forcing by Using PCM600
64
How to Undo Forcing Changes and Return the IED to Normal Operation
66
Undo Forcing by Using TESTMODE Component
66
Undo Forcing by Using LHMI
66
Undo Forcing by Using PCM600
66
Section 10 Testing Functionality by Secondary Injection
69
Testing Disturbance Report
69
Introduction
69
Disturbance Report Settings
69
Disturbance Recorder (DR)
69
Event Recorder (ER) and Event List (EL)
70
Identifying the Function to Test in the Technical Reference Manual
70
Differential Protection
70
High Impedance Differential Protection HZPDIF
70
Verifying the Settings
71
Completing the Test
71
Impedance Protection
71
Distance Protection Zones, Quadrilateral and Mho Characteristic ZMFPDIS
71
Measuring the Operating Limit of Set Values
74
Measuring the Operating Time of Distance Protection Zones
75
Completing the Test
75
Automatic Switch Onto Fault Logic ZCVPSOF
75
Activating ZCVPSOF Externally
76
Initiating ZCVPSOF Automatically and Setting Mode to Impedance
76
Initiating ZCVPSOF Automatically and Setting Mode to Uilevel
76
Completing the Test
76
Current Protection
76
Instantaneous Phase Overcurrent Protection 3-Phase Output PHPIOC
76
Measuring the Operate Limit of Set Values
77
Completing the Test
77
Four Step Phase Overcurrent Protection 3-Phase Output OC4PTOC
77
Verifying the Settings
77
Completing the Test
78
Instantaneous Residual Overcurrent Protection EFPIOC
78
Measuring the Operate Limit of Set Values
78
Completing the Test
79
Four Step Residual Overcurrent Protection, (Zero Sequence or Negative Sequence Directionality) EF4PTOC
79
Four Step Directional Earth Fault Protection
79
Four Step Non-Directional Earth Fault Protection
79
Completing the Test
80
Breaker Failure Protection, Phase Segregated Activation and Output CCRBRF
80
Checking the Phase Current Operate Value, IP
80
Checking the Residual (Earth Fault) Current Operate Value IN> Set below IP
80
Checking the Re-Trip and Back-Up Times
81
Verifying the Re-Trip Mode
81
Verifying the Back-Up Trip Mode
81
Verifying Instantaneous Back-Up Trip at CB Faulty Condition
82
Verifying the Case Retripmode = Contact
82
Verifying the Function Mode Current&Contact
83
Completing the Test
83
Pole Discordance Protection CCPDSC
83
Verifying the Settings
83
Completing the Test
84
Voltage Protection
84
Two Step Undervoltage Protection UV2PTUV
84
Verifying the Settings
84
Completing the Test
85
Two Step Overvoltage Protection OV2PTOV
86
Verifying the Settings
86
Extended Testing
86
Completing the Test
86
Two Step Residual Overvoltage Protection ROV2PTOV
86
Verifying the Settings
87
Completing the Test
87
Loss of Voltage Check LOVPTUV
87
Measuring the Operate Limit of Set Values
87
Completing the Test
88
Multipurpose Protection
88
General Current and Voltage Protection CVGAPC
88
Built-In Overcurrent Feature (Non-Directional)
88
Overcurrent Feature with Current Restraint
89
Overcurrent Feature with Voltage Restraint
89
Overcurrent Feature with Directionality
90
Over/Undervoltage Feature
90
Completing the Test
90
Secondary System Supervision
90
Current Circuit Supervision CCSSPVC
90
Verifying the Settings
91
Completing the Test
91
Fuse Failure Supervision FUFSPVC
91
Checking that the Binary Inputs and Outputs Operate as Expected
91
Measuring the Operate Value for the Negative Sequence Function
92
Measuring the Operate Value for the Zero-Sequence Function
93
Measuring the Operate Value for the Dead Line Detection Function
93
Checking the Operation of the Du/Dt and DI/Dt Based Function
93
Completing the Test
94
Control
94
Synchrocheck, Energizing Check, and Synchronizing SESRSYN
94
Testing the Synchronizing Function
95
Testing the Synchrocheck Check
96
Testing the Energizing Check
98
Testing the Voltage Selection
99
Completing the Test
99
Autorecloser for 1/2/3-Phase Operation SMBRREC
99
Preparation of the Verification
101
Switching the Autorecloser for 1/2/3-Phase Operation Function to on and off
101
Verifying the Autorecloser Function SMBRREC
102
Checking the Reclosing Conditions
102
Completing the Test
104
Apparatus Control APC
104
Single Command, 16 Signals SINGLECMD
104
Interlocking
104
Scheme Communication
105
Scheme Communication Logic for Distance or Overcurrent Protection ZCPSCH
105
Testing Permissive Underreaching
105
Testing Permissive Overreaching
105
Testing Blocking Scheme
105
Testing Delta Blocking Scheme
106
Checking of Unblocking Logic
106
Completing the Test
107
Phase Segregated Scheme Communication Logic for Distance or Overcurrent Protection ZC1PPSCH
107
Testing Permissive Underreaching
107
Testing Permissive Overreaching
107
Testing Blocking Scheme
108
Completing the Test
108
Current Reversal and Weak-End Infeed Logic for Distance Protection 3-Phase ZCRWPSCH
108
Current Reversal Logic
108
Weak End Infeed Logic
109
Completing the Test
110
Local Acceleration Logic ZCLCPSCH
110
Verifying the Settings
110
Direct Transfer Trip Logic
110
Low Active Power and Power Factor Local Criteria LAPPGAPC
110
Compensated Over- and Undervoltage Protection COUVGAPC
111
Sudden Change in Current Variation SCCVPTOC
112
Carrier Receive Logic LCCRPTRC
112
Negative Sequence Overvoltage Protection LCNSPTOV
114
Zero Sequence Overvoltage Protection LCZSPTOV
115
Negative Sequence Overcurrent Protection LCNSPTOC
115
Zero Sequence Overcurrent Protection LCZSPTOC
116
Three Phase Overcurrent LCP3PTOC
116
Three Phase Undercurrent LCP3PTUC
117
Logic
117
Tripping Logic, Common 3-Phase Output SMPPTRC
117
Three-Phase Operating Mode
117
1Ph/3Ph Operating Mode
117
1Ph/2Ph/3Ph Operating Mode
118
Circuit Breaker Lockout
119
Completing the Test
120
Monitoring
120
Gas Medium Supervision SSIMG
120
Testing the Liquid Medium Supervision for Alarm and Lock out Conditions
120
Liquid Medium Supervision SSIML
120
Testing the Liquid Medium Supervision for Alarm and Lock out Conditions
121
Completing the Test
121
Breaker Monitoring SSCBR
121
Verifying the Settings
121
Completing the Test
123
Event Function EVENT
123
Fault Locator LMBRFLO
123
Measuring the Operate Limit
124
Completing the Test
124
Limit Counter L4UFCNT
124
Completing the Test
125
Metering
125
Pulse-Counter Logic PCFCNT
125
Function for Energy Calculation and Demand Handling ETPMMTR
125
Verifying the Settings
125
Completing the Test
126
Station Communication
126
Multiple Command and Transmit MULTICMDRCV / MULTICMDSND
126
Basic IED Functions
127
Parameter Setting Group Handling SETGRPS
127
Verifying the Settings
127
Completing the Test
127
Exit Test Mode
127
Section 11 Checking the Directionality
129
Overview
129
Testing the Directionality of the Distance Protection
129
Section 12 Commissioning and Maintenance of the Fault Clearing System
131
Commissioning Tests
131
Periodic Maintenance Tests
131
Visual Inspection
132
Maintenance Tests
132
Preparation
132
Recording
132
Secondary Injection
132
Alarm Test
133
Self Supervision Check
133
Trip Circuit Check
133
Measurement of Service Currents
133
Restoring
134
Section 13 Troubleshooting
135
Checking the Self Supervision Signals
135
Checking the Self Supervision Function
135
Determine the Cause of an Internal Failure
135
Self Supervision HMI Data
135
General IED Status
135
Fault Tracing
136
Internal Fault Indications
136
Using Front-Connected PC
137
Diagnosing the IED Status Via the LHMI Hint Menu
138
Hardware Re-Configuration
139
Repair Instruction
140
Repair Support
141
Maintenance
141
Section 14 Glossary
143
Advertisement
ABB RELION REL650 Commissioning Manual (152 pages)
Line distance protection
Brand:
ABB
| Category:
Protection Device
| Size: 3.6 MB
Table of Contents
Table of Contents
7
Introduction
15
This Manual
15
Intended Audience
15
Product Documentation
16
Product Documentation Set
16
Document Revision History
17
Related Documents
17
Symbols and Conventions
18
Symbols
18
Document Conventions
18
Safety Information
19
Symbols on the Product
19
Warnings
19
Caution Signs
20
Note Signs
21
Available Functions
23
Main Protection Functions
23
Back-Up Protection Functions
23
Control and Monitoring Functions
25
Station Communication
28
Basic IED Functions
30
Starting up
33
Factory and Site Acceptance Testing
33
Commissioning Checklist
33
Checking the Power Supply
34
Energizing the IED
34
Checking the IED Operation
34
IED Start-Up Sequence
34
Setting up Communication between PCM600 and the IED
35
Writing an Application Configuration to the IED
40
Checking CT Circuits
41
Checking VT Circuits
41
Using the RTXP Test Switch
42
Checking Binary Input and Output Circuits
42
Binary Input Circuits
42
Binary Output Circuits
43
Checking Optical Connections
43
Establishing Connection and Verifying the IEC 61850 Station Communication
45
Setting the Station Communication
45
Verifying the Station Communication
45
Testing IED Operation
47
Preparing the IED to Verify Settings
47
Activating the Test Mode
48
Preparing the Connection to the Test Equipment
49
Connecting the Test Equipment to the IED
49
Releasing the Function to be Tested
50
Verifying Analog Primary and Secondary Measurement
51
Testing the Protection Functionality
52
Testing Functionality
53
Testing Disturbance Report
53
Introduction
53
Disturbance Report Settings
53
Identifying the Function to Test in the Technical Reference Manual
53
Testing Impedance Protection Functions
53
Five Zone Distance Protection, Quadrilateral and Mho Characteristic ZQMPDIS
53
Quadrilateral Characteristics
54
Mho Characteristics
56
Measuring the Operating Limit of Set Values with Shaped Load Encroachment Characteristics
58
Measuring the Operate Time of Distance Protection Zones
58
Completing the Test
58
Phase Selection with Load Encroachment, Quadrilateral Characteristic FDPSPDIS
58
Measuring the Operate Limit of Set Values
60
Completing the Test
61
Faulty Phase Identification with Load Encroachment FMPSPDIS
61
Phase Preference Logic PPLPHIZ
61
Completing the Test
62
Power Swing Detection ZMRPSB
62
Verifying the Settings
63
Testing the Power Swing Detection Function ZMRPSB
64
Testing the Tr1 Timer
64
Completing the Test
64
Automatic Switch Onto Fault Logic, Voltage and Current Based ZCVPSOF
65
External Activation of ZCVPSOF
65
Automatic Initiation of ZCVPSOF
65
Completing the Test
65
Testing Current Protection Functions
66
Instantaneous Phase Overcurrent Protection 3-Phase Output PHPIOC
66
Measuring the Operate Limit of Set Values
66
Completing the Test
66
Instantaneous Phase Overcurrent Protection Phase Segregated Output SPTPIOC
66
Completing the Test
67
Four Step Phase Overcurrent Protection 3-Phase Output OC4PTOC
67
Verifying the Settings
67
Completing the Test
68
Four Step Phase Overcurrent Protection Phase Segregated Output OC4SPTOC
68
Verifying the Settings
68
Completing the Test
69
Instantaneous Residual Overcurrent Protection EFPIOC
69
Measuring the Operate Limit of Set Values
69
Completing the Test
70
Four Step Residual Overcurrent Protection, Zero or Negative Sequence Direction EF4PTOC
70
Four Step Directional Residual Overcurrent Protection
70
Four Step Non-Directional Residual Overcurrent Protection
71
Completing the Test
71
Sensitive Directional Residual Overcurrent and Power Protection SDEPSDE
71
Measuring the Operate and Time Limit for Set Values
71
Completing the Test
75
Thermal Overload Protection, One Time Constant, Celsius/Fahrenheit LCPTTR/LFPTTR
75
Testing the Protection Without External Temperature Compensation (Noncomp)
75
Completing the Test
76
Breaker Failure Protection, Phase Segregated Activation and Output CCRBRF
76
Checking the Phase Current Operate Value, IP
76
Checking the Residual (Earth Fault) Current Operate Value IN> Set below IP
77
Checking the Re-Trip and Back-Up Times
77
Verifying the Re-Trip Mode
77
Verifying the Back-Up Trip Mode
78
Verifying the Case Retripmode = Contact
78
Verifying the Function Mode Current&Contact
79
Completing the Test
79
Breaker Failure Protection, Phase Segregated Activation and Output CSPRBRF
79
Checking the Phase Current Operate Value, IP
80
Checking the Residual (EF) Current Operate Value IN> Set below IP
80
Checking the Re-Trip and Back-Up Times
80
Verifying the Retripmode
81
Verifying the Case Retripmode = no CB Pos Check
81
Verifying the Function Mode Current&Contact
81
Checking the Case with Fault Current below Set Value I>Blkcont
82
Checking the Phase Current Operate Value, IP
82
Completing the Test
82
Stub Protection STBPTOC
83
Measuring the Operate Limit of Set Values
83
Completing the Test
83
Pole Discordance Protection CCRPLD
83
Verifying the Settings
84
Completing the Test
84
Broken Conductor Check BRCPTOC
84
Measuring the Operate and Time Limit of Set Values
84
Completing the Test
85
Directional Underpower Protection GUPPDUP
85
Verifying the Settings
85
Completing the Test
86
Directional Overpower Protection GOPPDOP
86
Verifying the Settings
87
Completing the Test
87
Testing Voltage Protection Functions
87
Two Step Undervoltage Protection UV2PTUV
87
Verifying the Setting
87
Completing the Test
89
Two Step Overvoltage Protection OV2PTOV
89
Verification of Single-Phase Voltage and Time Delay to Operate for Step 1
89
Completing the Test
90
Two Step Residual Overvoltage Protection ROV2PTOV
90
Verifying the Settings
90
Completing the Test
91
Loss of Voltage Check LOVPTUV
91
Measuring the Operate Limit of Set Values
91
Completing the Test
92
Testing Frequency Protection Functions
92
Underfrequency Protection SAPTUF
92
Verifying the Settings
92
Completing the Test
93
Overfrequency Protection SAPTOF
93
Verifying the Settings
94
Completing the Test
95
Rate-Of-Change Frequency Protection SAPFRC
95
Verifying the Settings
95
Testing Secondary System Supervision Functions
96
Current Circuit Supervision CCSRDIF
96
Verifying the Settings
96
Completing the Test
96
Fuse Failure Supervision SDDRFUF
96
Checking that the Binary Inputs and Outputs Operate as Expected
96
Measuring the Operate Value for the Negative Sequence Function
97
Measuring the Operate Value for the Zero-Sequence Function
98
Checking the Operation of the Du/Dt and DI/Dt Based Function
98
Completing the Test
99
Testing Control Functions
99
Synchrocheck, Energizing Check, and Synchronizing SESRSYN
99
Testing the Synchronizing Function
101
Testing the Synchrocheck Check
102
Testing the Energizing Check
105
Testing the Voltage Selection
106
Completing the Test
106
Autorecloser for 3-Phase Operation SMBRREC
106
Preparation of the Verification
108
Switching the Autorecloser for 3-Phase Operation Function to
108
Verifying the Autorecloser for 3-Phase Operation Function SMBRREC
109
Checking the Reclosing Conditions
109
Completing the Test
110
Autorecloser for 1/3-Phase Operation STBRREC
110
Preparation of the Verification
112
Switching the Auto-Reclosing Function on and off
112
Verifying the Auto-Reclosing Function
113
Checking the Reclosing Conditions
113
Checking the Influence of the INHIBIT Signal
113
Check Closing Onto a Fault
113
Checking the Influence of CB Not Ready for Reclosing
114
Checking the Influence of Synchrocheck (at Three-Phase Reclosing)
114
Restoring Equipment
114
Completing the Test
114
Interlocking
114
Apparatus Control APC
115
Testing Scheme Communication Functions
115
Scheme Communication Logic with Delta Based Blocking Scheme Signal Transmit ZCPSCH
115
Testing Permissive Underreaching
115
Testing Permissive Overreaching
116
Testing Blocking Scheme
116
Testing Delta Blocking Scheme
116
Checking of Unblocking Logic
117
Completing the Test
117
Current Reversal and WEI Logic for Distance Protection 3-Phase ZCRWPSCH
117
Current Reversal Logic
117
Weak-End Infeed Logic at Permissive Schemes
118
Testing Conditions
118
Completing the Test
119
Current Reversal and WEI Logic for Distance Protection, Phase Segregated ZCWSPSCH
119
Current Reversal Logic
119
Weak-End Infeed Logic at Permissive Schemes
119
Testing Conditions
120
Completing the Test
120
Local Acceleration Logic ZCLCPLAL
120
Verifying the Settings
121
Completing the Test
121
Scheme Communication Logic for Residual Overcurrent Protection ECPSCH
121
Testing the Directional Comparison Logic Function
121
Completing the Test
122
Current Reversal and Weak-End Infeed Logic for Residual Overcurrent Protection ECRWPSCH
123
Testing the Current Reversal Logic
123
Testing the Weak-End Infeed Logic
123
Completing the Test
125
Testing Logic Functions
125
Tripping Logic, Common 3-Phase Output SMPPTRC
125
Three-Phase Operating Mode
125
Circuit Breaker Lockout
125
Completing the Test
126
Tripping Logic Phase Segregated Output SPTPTRC
126
1Ph/3Ph Operating Mode
126
Circuit Breaker Lockout
127
Completing the Test
127
Testing Monitoring Functions
127
Event Counter CNTGGIO
127
Limit Counter L4UFCNT
127
Completing the Test
128
Fault Locator LMBRFLO
128
Measuring the Operate Limit
129
Completing the Test
129
Testing Metering Functions
129
Pulse Counter PCGGIO
129
Testing Station Communication
130
Establishing Connection and Verifying the IEC 61850 Communication
130
Overview
130
Setting the Station Communication
130
Verifying the Station Communication
131
Exit Test Mode
131
Commissioning and Maintenance of the Fault Clearing System
133
Commissioning Tests
133
Periodic Maintenance Tests
133
Visual Inspection
134
Maintenance Tests
134
Troubleshooting
137
Fault Tracing
137
Identifying Hardware Errors
137
Identifying Runtime Errors
137
Identifying Communication Errors
137
Checking the Communication Link Operation
137
Checking the Time Synchronization
138
Running the Display Test
138
Indication Messages
138
Internal Faults
138
Warnings
139
Additional Indications
139
Correction Procedures
140
Changing and Setting the Password
140
Identifying IED Application Problems
140
Inspecting the Wiring
140
Glossary
145
ABB RELION REL650 Operation Manual (66 pages)
Brand:
ABB
| Category:
Protection Device
| Size: 4.52 MB
Table of Contents
Table of Contents
7
Introduction
11
This Manual
11
Intended Audience
11
Product Documentation
12
Product Documentation Set
12
Document Revision History
13
Related Documents
13
Document Symbols and Conventions
15
Symbols
15
Document Conventions
16
Safety Information
17
Symbols on the Product
17
Warnings
17
Caution Signs
18
Note Signs
19
Environmental Aspects
21
Sustainable Development
21
Disposing of the IED
21
Using the HMI
23
Using the Local HMI
23
On-Screen Keyboard
23
Logging on
24
Logging off
26
Turning the Display Backlight on
26
Identifying the Device
26
Adjusting the Display Contrast
27
Navigating in the Menu
27
Menu Structure
27
Scrolling the Display
28
Changing the Default View
28
Browsing Setting Values
28
Editing Values
29
Editing Numerical Values
29
Editing String Values
30
Editing Enumerated Values
30
Changing Time Settings in LHMI
30
Saving Settings
31
Clearing and Acknowledging
31
Using the Local HMI Help
31
IED Operation
33
Normal Operation
33
Disturbance Identification
33
Disturbance Recording Triggering
33
Disturbance Record Analysis
33
Disturbance Reports
34
IED Self-Supervision
34
Non-Operative Functions
34
IED Parameterization
35
IED Settings for IED Functionality
35
IED Settings for Different Operating Conditions
35
Operating Procedures
37
Monitoring
37
Indications
37
Monitoring an Internal IED Fault
37
Recorded Data
37
Creating Disturbance Recordings
38
Monitoring Disturbance Recorder Data
38
Controlling and Reading Disturbance Recorder Data
39
Monitoring Events
40
Remote Monitoring
40
Monitoring the IED Remotely
40
Through Fault Monitoring Report
41
Through Fault Monitoring Tool
41
Through Fault Monitoring Using Local HMI
46
Resetting the IED
47
Clearing and Acknowledging Via the Local HMI
47
Changing the IED Functionality
48
Defining the Setting Group
48
Activating a Setting Group
48
Browsing and Editing Setting Group Values
49
Troubleshooting
51
Fault Tracing
51
Identifying Hardware Errors
51
Identifying Runtime Errors
51
Identifying Blocked Functions
51
Identifying Communication Errors
51
Checking the Communication Link Operation
52
Checking the Time Synchronization
52
Diagnosing the IED Status Via the LHMI Hint Menu
52
Indication Messages
53
Internal Faults
53
Warnings
53
Additional Indications
54
Correction Procedures
54
Creating User Accounts and Setting and Changing Passwords
54
Changing the Password from the LHMI
54
Identifying IED Application Problems
55
Inspecting the Wiring
55
Glossary
57
Advertisement
Advertisement
Related Products
ABB RELION 650 SERIES
ABB RELION REM615
ABB Relion REG650
ABB REL650 series
ABB Relion REL670 2.1 IEC
ABB REL670 2.2 IEC
ABB REL 531
ABB REL650 A11
ABB REL650 A12
ABB REL 501-C1 2.5