Filter Replacement - Electrolux ELAP15 Owner's Manual

Hide thumbs Also See for ELAP15:
Table of Contents

Advertisement

Available languages

Available languages

FILTER REPLACEMENT

ELAP15, ELAP30
There are two separate filters:
Carbon Pre-Filter and HEPA filter.
• The Check Filter indicator will signal when
to replace the HEPA filter. The replace-
ment period will vary depending on the
hours of usage, air quality, and location
of the unit. However, in most cases of
normal use, the filter will need to be
replaced annually.
• For best performance, change the Carbon
Pre-Filter every three months.
The filters should be disposed off when
changed. Do not wash and reuse the HEPA
filter or the Carbon Pre-Filter as they will
not work effectively.
CAUTION: Turn off the air cleaner
!
and unplug the electrical cord before
performing any maintenance
Carbon Pre-Filter replacement
1. Turn off the air cleaner and unplug the
electrical cord.
2. Remove the front panel by pulling gently
from the lower portion of the panel. Do
not force, the panel should remove
easily.
3. Remove the Carbon Pre-Filter by gently
pulling out from the bottom and down
from the top.
4. Remove the Carbon Pre-Filter and
dispose of it.
5. Remove a replacement Carbon Pre-Filter
from the resealable plastic bag and
reseal to maintain the freshness
of the remaining filter.
6. Install the Carbon Pre-Filter.
10
www.electrolux.com
ELAP40
There are two separate filters:
High Deodorization Anti-Odor
Carbon Filter and HEPA filter.
• The Check Filter indicator will signal when
• For best performance, change the High
.
and unplug the electrical cord before
performing any maintenance
High Deodorization Anti-Odor
Carbon Filter replacement
1. Turn off the air cleaner and unplug the
2. Remove the front panel by pulling gently
3. Remove the High Deodorization Anti-
4. Remove the High Deodorization Anti-
5. Remove a replacement High Deodoriza-
6. Install the High Deodorization Anti-Odor
to replace the HEPA filter. The replace-
ment period will vary depending on the
hours of usage, air quality, and location
of the unit. However, in most cases of
normal use, the filter will need to be
replaced annually.
Deodorization Anti-Odor Carbon Filter
every 12 months. The filters should be
disposed off when changed. Do not wash
and reuse the HEPA filter or the High
Deodorization Anti-Odor Carbon Filter as
they will not work effectively.
CAUTION: Turn off the air cleaner
!
electrical cord.
from the lower portion of the panel. Do
not force, the panel should remove
easily.
Odor Carbon Filter by gently pulling out
from the bottom and down from the top.
Odor Carbon Filter and dispose of it.
tion Anti-Odor Carbon Filter from its
plastic bag.
Carbon Filter.
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elap30Elap45Elap40

Table of Contents