FUJITSU Server PRIMEQUEST 2000 Series Message Reference CA92344-0540-06...
Page 2
Overview of Messages Preface This manual describes the functions and features of the PRIMEQUEST 2000 series. The manual is intended for system administrators. For details on the regulatory compliance statements and safety precautions, see the PRIMEQUEST 2000 Series Safety and Regulatory Information (CA92344-0523).
Overview of Messages Revision History Edition Date Revised location (type) Description - The edition is initialized to "01" for changing manual code 2014-08-12 All pages - Added descriptions about Extended Partitioning function - Secure Boot 2014-10-07 CHAPTER2 MMB Messages - RHEL7 2015-02-03 CHAPTER2 MMB Messages - Added descriptions about PRIMQUEST 2400E2/2800E2/...
Similarly, one space line is inserted before and after the alert statement. Only Fujitsu certified service engineers should perform the following tasks on this product and the options provided by Fujitsu. Customers must not perform these tasks under any circumstances.
Page 5
Overview of Messages List of important alert items This manual does not contain important alert items. Warning labels Never remove the warning labels. Warning label location (the main cabinet top) CA92344-0540-06...
Page 6
Overview of Messages Warning label location (the main cabinet left) Warning label location (PCI_Box) CA92344-0540-06...
For stable operation of the PRIMEQUEST 2000 series server, use only a Fujitsu-certified optional product as an added option. Note that the PRIMEQUEST 2000 series server is not guaranteed to operate with any optional product not certified by Fujitsu. Exportation/release of this product Exportation/release of this product may require necessary procedures in accordance with the regulations of the Foreign Exchange and Foreign Trade Control Law of Japan and/or US export control laws.
Page 8
Product and service inquiries For all product use and technical inquiries, contact the distributor where you purchased your product, or a Fujitsu sales representative or systems engineer (SE). If you do not know the appropriate contact address for inquiries about the PRIMEQUEST 2000 series, use the Fujitsu contact line.
Page 9
Be sure to keep this manual in a safe and convenient location for quick reference. Fujitsu makes every effort to prevent users and bystanders from being injured and to prevent property damage. Be sure to use the product according to the instructions in this manual.
Page 10
Defines the PRIMEQUEST 2000 series related terms and CA92344-0541 Glossary abbreviations. Related manuals The following manuals relate to the PRIMEQUEST 2000 series. You can access these manuals at the following site: http://www.fujitsu.com/global/services/computing/server/primequest/ http://manuals.ts.fujitsu.com/ Contact your sales representative for inquiries about the ServerView manuals.
Page 11
Overview of Messages Title Description LSI Integrated RAID SAS 3.0 Solution PRAID EP420e Refer to the following URL: The Fujitsu Technology Solutions manuals server http://manuals.ts.fujitsu.com/ Abbreviations This manual uses the following product name abbreviations. Formal product name Abbreviation Microsoft ® Windows Server ® 2012 R2 Datacenter Windows, Windows Server 2012 Microsoft ®...
The PDF file of this manual is intended for display using Adobe® Reader® in single page viewing mode at 100% zoom. This manual shall not be reproduced or copied without the permission of Fujitsu Limited. Copyright 2014-2015 FUJITSU LIMITED CA92344-0540-06...
Overview of Messages Contents CHAPTER 1 Overview of Messages ................................ 1 How to read the MMB messages ..............................1 1.1.1 System event log ..................................1 CHAPTER 2 MMB Messages ................................... 3 MMB Message list ..................................3 2.1.1 Temperature sensor-related messages ..........................4 2.1.2 Voltage Sensor Related................................
Page 14
Overview of Messages Figures FIGURE 1.1 Information area ................................... 1 FIGURE 1.2 [System Event Log] window ..............................2 CA92344-0540-06 xiii...
Page 15
Overview of Messages Tables TABLE 2.1 Messages sent even by Info ..............................3 TABLE A.1 Replacement component list 1 ............................215 TABLE A.2 Replacement component list 2 ............................216 CA92344-0540-06...
This chapter describes how to read the messages that are stored in the MMB. For the details on how to open the MMB window, see ‘1.7 Basic operations of the Web-UI window’ in the PRIMEQUEST 2000 series User Interface Operating Instructions (CA92344-0538). For the MMB messages, see Chapter 2 MMB Messages.
Page 17
System Event Log] window display items For details on the display items of the [System Event Log] window, see 1.2.2 [System Event Log] window in the PRIMEQUEST 2000 series Operations Management Tool Reference (CA92344-0539). Downloading the data Save the system event log as it is important information for investigation. It is important material when contacting your sales representative or a field engineer.
CHAPTER 2 MMB Messages This chapter lists MMB messages by type. For details on how to open an MMB window, see 1.7 Basic Operations in the Web-UI Window in the PRIMEQUEST 2000 Series User Interface Operating Instructions (CA92344-0538EN). MMB Message list This chapter describes the messages of the system even log which is displayed in the MMB Web-UI.
MMB Messages 2.1.1 Temperature sensor-related messages Temperature Sensor related messages are listed below. 010100FF Lower Non-critical - going low Assert $$$ C threshold: $$$ Meaning: Low temperature warning has occurred. Corrective action: Check whether the monitored temperature has decreased as shown below, in the environment of the server installed locations.
MMB Messages 018107FF Upper Non-critical - going high Deassert $$$℃ threshold: $$$ ℃ Meaning: High-temperature warning was canceled. Corrective action: No action is necessary. Severity: Info 018109FF Upper Critical - going high Deassert$$$°C threshold: $$$°C Meaning: High-temperature error was canceled. Corrective action: No action is necessary.
Page 21
MMB Messages 020107FF Upper Non-critical - going high Assert $$$V threshold: $$$V Meaning: High voltage warning has occurred. Corrective action: Target board must be replaced. When “Unit” in SEL is SB#xx identify the replacement parts by referring to ‘TABLE A.2 Replacement component list 2’.
MMB Messages 2.1.3 Fan Related Fan related messages are listed below. 040102FF Lower Critical - going low Assert $$$rpm threshold: $$$rpm Meaning: Low FAN rpm error has occurred. Corrective action: Replace the target IO_FAN or FANM. When the situation does not improve even if FANM is exchanged, replace the target PSU or FANU.
MMB Messages 040B05FF Non-redundant: Insufficient Resource Meaning: FAN is non-redundant, and the fans that are mounted are not sufficient for continuing the system operation. Corrective action: If the FANs basically not adequate, increase the number of FANs. And if the number of FANs had been reduced due to FAN failure, see the FAN failure message and replace the faulty fan.
Page 24
MMB Messages 086F0205 Power Supply input over voltage warning Meaning: Input over voltage warning has occurred. Corrective action: Replace the target PSU. Severity: Warning 086F0206 Power Supply input over power warning Meaning: Input over power warning has occurred. Corrective action: Replace the target PSU.
Page 25
MMB Messages 086F0602 Configuration error in excess unit Meaning: PSU mounting location is wrong. Corrective action: Check the PSU mounting location. Severity: Error 08EF00FF Removed Meaning: The PSU was removed. Corrective action: No action is necessary. Severity: Info 08EF03FF Power Supply input is restored Meaning: The power supply was restored.
MMB Messages 090B05FF Non-redundant: Insufficient Resource Meaning: The mounted PSUs are not sufficient for system operation. Corrective action: Check for any faulty PSU, and if the mounted PSUs are sufficient for system configuration. Severity: Error 2.1.5 MMB related MMB related messages are lased below. 15070103 Chassis Information access failure Meaning:...
Page 27
MMB Messages 1507011B MMB Firmware error Meaning: The firmware may be damaged. Corrective action: An MMB must be replaced. Contact your sales representative or a field engineer. Severity: Warning 15070175 Correctable error logging limit reached Meaning: Correctable errors have occurred frequently, and have reached the replacement threshold. Corrective action: An MMB must be replaced.
Page 28
MMB Messages 1507020E Configuration Data error MMB Meaning: The configuration data may be corrupted. Corrective action: An MMB must be replaced. If the problem persists, another MMB must be replaced. Severity: Error Remarks This error is basically from the Standby side. 15070261 HUB failure Meaning:...
Page 29
MMB Messages 1507028D Diag: MRAM Error Meaning: An error was detected in the MRAM. Corrective action: An MMB must be replaced. Contact your sales representative or a field engineer. Severity: Error 15070293 Diag: RTC Time Operation Error Meaning: An error was detected in the internal clock. Corrective action: An MMB must be replaced.
Page 30
MMB Messages 150702AB Diag: NIC Device Not Found Meaning: NIC Device could not be found. Corrective action: An MMB must be replaced. Contact your sales representative or a field engineer. Severity: Error 150702AD Diag: MRAM Write/read Error Meaning: A MRAM Write/Read error was detected. Corrective action: An MMB must be replaced.
Page 31
MMB Messages 150702EB Diag: NIC Register Error Meaning: A register read error was detected. Corrective action: An MMB must be replaced. Contact your sales representative or a field engineer. Severity: Error 15070380 Diag: General Purpose Register Error Meaning: A register write error was detected. Corrective action: An MMB must be replaced.
Page 32
MMB Messages 15070388 Diag: NAND FMEM Fsck Error Meaning: The content of the file system is incorrect. The error of the file system cannot be corrected. Corrective action: An MMB must be replaced. Contact your sales representative or a field engineer. Severity: Error 15070390...
Page 33
MMB Messages 150703A0 Diag: System Timer Operation error Meaning: The System Timer operation is not normal. Corrective action: An MMB must be replaced. Contact your sales representative or a field engineer. Severity: Error 150703A2 Diag: SDRAM Uncorrectable Error Meaning: Uncorrectable error has occurred. Corrective action: An MMB must be replaced.
Page 34
MMB Messages 150703C4 Diag: L2 Cache Correctable Error did not occur Meaning: The L2 cache correctable error could not be detected. Corrective action: An MMB must be replaced. Contact your sales representative or a field engineer. Severity: Error 150703D4 Diag: L2 Cache Tag Parity Error Meaning: An L2 cache tag parity error was detected.
MMB Messages 28070812 User Port#0 halted Meaning: User Port#0 of the MMB has entered the Link Down state. Corrective action: Check for an errors in the User Port network. Severity: Info 28070813 User Port#1 halted Meaning: User Port#1 of the MMB has entered the Link Down state. Corrective action: Check for an errors in the User Port network.
MMB Messages 2B6F0401 Configuration error: Board type Meaning: Memory Scale-up Board is mounted. Corrective action: Replace the Memory Scale-up Board by SB. Severity: Error 2B6F0402 Configuration Number of units Meaning: The Number of mounted SB or Memory Scale-up Board exceeds limitation. Corrective action: Check configuration and remove SB or Memory Scale-up Board from Chassis.
MMB Messages 2.1.8 PCI_Box related The PCI_Box related messages are listed below. 180700FF Transition to OK Meaning: Normal state. Corrective action: No action is necessary. Severity: Info 180701FF Transition to Non-critical from OK Meaning: There has been a transition from the normal state to a warning state. Corrective action: Target unit must be replaced.
MMB Messages 2.1.9 PEXU related PEXU related messages are listed below. 1B6F00FF Cable is connected Meaning: The IOU connection cable is connected. Corrective action: No action is necessary. Severity Info 1B6F0100 Incorrect connection (Number of PCI_Box) Meaning: The maximum number of PCI_Boxes that can be connected has been exceeded. Corrective action: Disconnect the excess PCI_Boxes.
MMB Messages 1B6F0150 Incorrect connection (Illegal disconnect) Meaning: The PCI_Box cable connected to the indicated port may be removed when the related partition is power-on. Corrective action: Check the cable connected to the PCI_Box. Severity: Warning 1B6F01A0 Invalid ID SW operation Meaning: Incorrect operation of the ID switch.
MMB Messages 280300C0 BMC-MMB LAN Failure Meaning: Error was detected in the communication with the BMC during the Private LAN monitoring. Corrective action: The system board must be replaced. If the error persists, the active MMB must be replaced. Severity: Warning 280701C0 BMC-MMB LAN Error...
Page 41
MMB Messages 2C6F01FF FRU Inactive Meaning: The component has stopped operating. Corrective action: No action is necessary. Severity: Info 2C6F02FF FRU Activation Requested Meaning: Addition of the component has been requested. Corrective action: No action is necessary. Severity: Info 2C6F0705 FRU Comm Lost Meaning: The fuse has blown.
MMB Messages 2.1.12 BMC related The BMC related messages are listed below. ■Temperature Sensor related (BMC) B0010571 'CPU#0 Temp': Temperature high warning: $$ C Meaning: A temperature rise (Warning) was detected. Corrective action: If the Inlet Temp is normal and CPU Temp is abnormal, please check the state of the filter, the heat sink and installation environment.
Page 43
MMB Messages B0018572 'CPU#1 Temp': Temperature OK Meaning: The temperature is now normal. Corrective action: No action is necessary. Severity: Info B0018591 'CPU#0 Temp': Temperature high warning: $$ C Meaning: A temperature rise (Warning) was detected. Corrective action: If the Inlet Temp is normal and CPU Temp is abnormal, please check the state of the filter, the heat sink and installation environment.
Page 44
MMB Messages B00744FF 'CPU#$$': CPU startup/init failure; disabled Meaning: A CPU error has occurred. Corrective action: Replace the CPU. Severity: Error B0076100 'CPU#$$': CPU thermal trip alert deasserted Meaning: Abnormal temperature was detected in the CPU. Corrective action: Replace the CPU. Severity Error B0076101...
Page 45
MMB Messages B0076B01 'CPU#$$' Information ROM access error Meaning: A CPU error has occurred. Corrective action: Replace the CPU. Severity: Error B0076B02 'CPU#$$’: boot code error Meaning: A CPU error has occurred. Corrective action: Replace the CPU. Severity: Error B0076B03 'CPU#$$’: register verify error Meaning: A CPU error has occurred.
Page 46
MMB Messages B00FE0C8 POST – SecureBoot isn’t configured correctly Meaning: Configuration of Secure boot is incorrect. There is Boot Device or OS loader which is not supported Secure Boot in partition. Or, the Key or the DB for Secure Boot is deficient in UEFI Corrective action: Please check Device and the setting of UEFI.
Page 47
MMB Messages B0196004 'I2C EEPROM' access failure Meaning: An error occurred in BMC EEPROM Corrective action: Replace the SB. Severity: Error ■Windows OS related (BMC) B01F00FF Boot from floppy disk completed Meaning: Booted. Corrective action: No action is necessary. Severity: Info B01F01FF Boot from hard drive completed...
Page 48
MMB Messages B01F06FF Boot from unspecified boot device completed Meaning: Booted. Corrective action: No action is necessary. Severity: Info B02000FF Critical stop during OS load or initialization Meaning: The OS has stopped abnormally. Corrective action: The software needs to be examined. Severity: Warning B02001FF...
Page 49
MMB Messages ■Watchdog related (BMC) B0236FFF 'Watchdog - Action: Timer Interrupt Meaning: Watchdog timer has timed out. For the operation to be performed after expiration of the Watchdog timer, the operation specified by Automatic Server Restart (ASR) Control is prioritized if the retry count specified by ASR Control has been exceeded.
Page 50
MMB Messages B0236F01 BIOS FRB2 - Action: Hard Reset Meaning: Watchdog timer has timed out. For the operation to be performed after expiration of the Watchdog timer, the operation specified by Automatic Server Restart (ASR) Control is prioritized if the retry count specified by ASR Control has been exceeded.
Page 51
MMB Messages ■I2C related (BMC) B0C00157 'I2C$ error ratio': above warning level An error has occurred in BMC I2C bus. Corrective action: Replace the SB. Severity: Warning B0C06F80 'I2C$': I2C Bus is blocked Meaning: I2C bus error has occurred in the BMC. Corrective action: Replace the SB.
Page 52
MMB Messages B0CB61$$ 'I2C#$' diagnostic error Meaning: An error occurred in BMC I2C bus. Corrective action: Replace the SB. Severity: Error B0CB62$$ 'I2C GPIO#$$' diagnostic error Meaning: An error has occurred in BMC GPIO. Corrective action: Replace the SB. Severity: Error B0CB6300 'I2C EEPROM' diagnostic error...
Page 53
MMB Messages B0CB6800 BMC Memory Uncorrectable error Meaning: A BMC error has occurred. Corrective action: Replace the SB. Severity: Error B0CB6900 BMC Memory Correctable error logging limit reached Meaning: A BMC error has occurred. Corrective action: Replace the SB. Severity: Warning ■CPU Status related (BMC) B0DB03FF...
Page 54
MMB Messages B0DE4CFF 'DIMM#$$$' Memory: Correctable error (ECC) Meaning: A correctable error has occurred in the memory. Corrective action: No action is necessary. Severity: Info ■Memory Module Configuration State related (BMC) B0DF6600 'DIMM#$$$' Memory: Mismatch in set Meaning: Same memory has not been mounted. Corrective action: Check the memory combination.
Page 55
MMB Messages ■SDR OEM Multiple Sensor related (BMC) B0EE8300 ASR&R counter exceeded restart tries Meaning: The ASR counter has exceeded the number of retries. Corrective action: No action is necessary. Severity: Info ■PCI related (BMC) BC503080 Legacy PCI Master Data PERR Bus: $$ Device: 0x$$ Function: 0x$$ Meaning: Error has been detected in the PCI or PCI express data.
Page 56
MMB Messages BC5030F0 Legacy PCI SERR Bus: $$ Device: 0x$$ Function: 0x$$ Meaning: An error was detected in the PCI or PCI express data. Corrective action: Referring the Source and Unit of the MMB system event log, replace the unit according Replacement Component Type A in the ‘TABLE A.1 Replacement component list 1 ‘.
Page 57
MMB Messages BC5040F0 PCI: Completer Abort Bus: $$ Device: 0x$$ Function: 0x$$ Meaning: An error was detected in the PCI express packet. Corrective action: Referring the Source and Unit of the MMB system event log, replace the unit according Replacement Component Type A in the ‘TABLE A.1 Replacement component list 1‘.
Page 58
MMB Messages BC504150 PCI: ACS Violation Bus: $$ Device: 0x$$ Function: 0x$$ Meaning: An error was detected in the PCI express packet. Corrective action: Referring the Source and Unit of the MMB system event log, replace the unit according Replacement Component Type A in the ‘TABLE A.1 Replacement component list 1 ‘.
Page 59
MMB Messages BC505060 PCI: Bad TLP Bus: $$ Device: 0x$$ Function: 0x$$ Meaning: A transmission system error of PCI express was detected, Corrective action: No action is necessary. Severity: Info BC505070 PCI: Bad DLLP Bus: $$ Device: 0x$$ Function: 0x$$ Meaning: A transmission system error of PCI express was detected, Corrective action:...
Page 60
MMB Messages BC507000 Driver Monitor Information: Message ID: $$ Meaning: An informative event from PCI card driver occurred Corrective action: No action is necessary. Severity: Info BC508000 Driver Monitor Warning: Message ID: $$ Meaning: A warning was detected by PCI driver Corrective action: Source of SEL is blank.
MMB Messages ■OS related (BMC) BDC$$$$$ Operating system boot $$$ Meaning: OS has booted. Corrective action: No action is necessary. Severity: Info BDD$$$$$ Operating system shutdown - $$$ Meaning: The operating system has shut down. The output in the wildcard may not correspond to the specified reason or comment. And a large number of messages may be output.
Page 62
MMB Messages C06F01FF Power On In Progress Meaning: The power on process is in progress. Corrective action: No action is necessary. Severity: Info C06F02FF Reset Meaning: Resetting is in progress. Corrective action: No action is necessary. Severity: Info C06F03FF Meaning: The EFI is in operation.
Page 63
MMB Messages C06F08FF Power Off In Progress Meaning: The partition power off is in progress. Corrective action: No action is necessary. Severity: Info C06F09FF Fatal Meaning: A fatal hardware error has occurred. Corrective action: No action is necessary. Severity: Info C06F0AFF Dumping Meaning:...
MMB Messages 2.1.14 MMB firmware related MMB firmware related messages are listed below. C5A10300 MMB Firmware Update Failed Meaning: MMB firmware updating has failed. Corrective action: MMB must be replaced. Severity: Error C5A10310 MMB#0 Firmware Update Failed Meaning: Rebooting after updating the MMB#0 firmware update has failed, and booting was done in the old version. Corrective action: MMB must be replaced.
MMB Messages C5A10361 MMB#1 Firmware Update Failed (NOR bank change error) Meaning: Switching of NOR bank has failed during the MMB#1 firmware update. Corrective action: MMB must be replaced. Severity Error C5A104FF Switch Over Failed Meaning: MMB Active/Standby switching has failed. Corrective action: MMB must be replaced.
Page 66
MMB Messages C8A10600 Uncorrectable Internal error Meaning: An Uncorrectable CPU or Memory Scale-up Controller error has occurred. Corrective action: CPU or Memory Scale-up Board must be replaced. Contact your sales representative or a field engineer. Severity: Error C8A10601 Uncorrectable QPI Path error { (SB#x-CPU#Y) } Meaning: An uncorrectable error was detected in the QPI transmission path between the CPUs(or Memory Scale-up Controllers).
MMB Messages C8A90602 SMI2 lane degraded Meaning: Lane degradation was detected in the interface between CPU/Memory Scale-up Controller with Memory Buffer. Corrective action: The target CPU, SB, Memory Scale-up Board or Mezzanine must be replaced. Contact your sales representative or a field engineer. Severity: Warning 2.1.16 PCI Express related...
Page 68
MMB Messages C8A10415 PCIe SW Upstream Completer Abort Meaning: A switch port error has occurred. Corrective action: The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer. Severity: Error C8A10416 PCIe SW Upstream Unexpected Completion Meaning: A switch port error has occurred.
Page 69
MMB Messages C8A1041C PCIe SW Upstream Uncorrectable Internal Error Meaning: A switch port error has occurred. Corrective action: The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer. Severity: Error C8A10490 PCIe SW Downstream Data link Protocol Error Meaning: An error has occurred in the switch.
Page 70
MMB Messages C8A10496 PCIe SW Downstream Unexpected Completion Meaning: A switch port error has occurred. Corrective action: The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer. Severity: Error C8A10497 PCIe SW Downstream Receiver Overflow Meaning: A switch port error has occurred.
Page 71
MMB Messages C8A10440 PCIe SW Upstream Access Failure Meaning: A switch i2C access error has occurred. Corrective action: The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer. Severity: Error C8A104C0 PCIe SW Downstream Access Failure Meaning: A switch i2C access error has occurred.
Page 72
MMB Messages C8A104C3 PCIe SW Downstream Other Error Meaning: A switch EEPROM error has occurred. Corrective action: The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer. Severity: Error C8A10444 PCIe SW Upstream Initialization Checksum Error Meaning: A switch EEPROM error has occurred.
Page 73
MMB Messages C8A10448 PCIe SW Upstream Blank Serial EEPROM Meaning: A switch EEPROM error has occurred. Corrective action: The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer. Severity: Error C8A104C8 PCIe SW Downstream Blank Serial EEPROM Meaning: A switch EEPROM error has occurred.
MMB Messages C8A20F00 Undetermined hardware fatal error Meaning: The failure location could not be determined by the MMB. Corrective action: Collect a detailed log, and determine the failure location, according to the analysis procedure for determining faulty locations provided by your sales representative or a field engineer. If the location of failure cannot be determined, contact your sales representative or a field engineer.
MMB Messages C9A30290 BMC Communication Failure Meaning: The error could not be resolved by BMC reset. Corrective action: The system board must be replaced. If the error persists, the Active MMB must be replaced. Severity: Error 2.1.18 RAID Related The messages related to the RAID are listed below. C8A10D00 RAID Card Uncorrectable error (VendorID=%04x/DeviceID=%04x/SubvendorID=%04x/Subsystem=%04x) on IOU_%dGbE...
Page 76
MMB Messages C8A70D03 RAID Card SAS topology error (VendorID=%04x/DeviceID=%04x/SubvendorID=%04x/Subsystem=%04x) on IOU_%dGbE Meaning: RAID Card SAS topology error Corrective action: Check if normal operation could be restored by each step. 1. Remove the physical disk drive, wait 30 seconds and install the disk drive. 2.
Page 77
MMB Messages C8A70E01 BBU on RAID controller: battery low Meaning: The battery voltage reduction was detected. Corrective action: Confirm whether the cable is correctly connected. Still, when the problem continues, it is necessary to exchange the FBU. Severity: Warning C8A70E02 BBU on RAID controller: failed Meaning: The battery breakdown was detected.
Page 78
MMB Messages C8A70E07 BBU on RAID controller: requires reconditioning; please initiate recalibration Meaning: The reconditioning of the battery is necessary. Corrective action: 1. Please do the recalibration. Please do not interrupt the charge by reboot and shutdown. 2. When the problem is not canceled, it is necessary to exchange the FBU. 3.
Page 79
MMB Messages E76F05FF Physical disk rebuilding model=$$ Meaning: The HDD rebuilding is in progress. Corrective action: No action is necessary. Severity: Info E76F06FF Physical disk Global Hot Spare created model=$$ Meaning: The HDD global hot spare was created. Corrective action: No action is necessary.
Page 80
MMB Messages E77E04FF Logical drive bad block table is full Meaning: The bad block table of logical drive is full. Corrective action: Check added error messages for the logical drive. Severity: Warning E77E03FF Logical drive failed Meaning: The logical drive broke down. Corrective action: It is likely to be able to recover without losing data.
Page 81
MMB Messages 297F0502 BBU on RAID controller: removed Meaning: The voltage has decreased remarkably. Corrective action: Please confirm firmware version of the RAID controller and update latest version. Please wait for the charge completion of the battery. Please exchange FBU when the problem is not canceled after the charge is completed.
MMB Messages 2.1.19 JX40 Related The messages related to the JX40 are listed below. E76F0200 Physical disk #n SMART error model=%m (predictive failure) (PCIBox#n-Slot#n-Port#n, Cascade#, %s) Meaning: The HDD error was detected by self-diagnosis. %s is disk enclosure model name. Corrective action: Replace the HDD.
Page 83
MMB Messages E76F0602 Physical disk #n Global hot spare assigned model=%m (PCIBox or IOU#n-Slot#n-Port#n, Cascade#, %s) Meaning: A global hot spare of HDD was generated. %s is disk enclosure model name. Corrective action: No action is necessary. Severity: Info E76F0700 Physical disk #n bad block table is full model=%m (PCIBox or IOU#n-Slot#n-Port#n, Cascade#, %s) Meaning: Bad block table of HDD exceeded it to capacity.
Page 84
MMB Messages E77E0400 Logical drive #n bad block table is full (PCIBox or IOU#n-Slot#n) Meaning: Bad block table of logical drive is full. Corrective action: Please confirm added error message of the disk drive. Severity: Warning C9A10F0X Fan#n will fail in near future (PCIBox#n-Slot#n-Port#n,Cascade #, %s) Meaning: The FAN will break down in the near future.
Page 85
MMB Messages C9A10F40 Temperature has reached the critical level (PCIBox#n-Slot#n-Port#n, Cascade #, %s) Meaning: A temperature rise (critical) was detected. %s is disk enclosure model name. Corrective action: Confirm the ambient temperature. if it is unquestionable, confirm FAN operates normally. Attention) Please do not operate the system with the cover removed.
Page 86
MMB Messages C9A10F90 EMM #n failed (PCIBox or IOU #n-Slot#n-Port#n, Cascade #, %s) Meaning: Problem of enclosure management module is detected. %s is disk enclosure model name. Corrective action: Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel.
Page 87
MMB Messages C9A10FA3 Enclosure unstable (PCIBox or IOU #n-Slot#n-Port#n, Cascade #, %s) Meaning: The operation of the enclosure is not steady. %s is disk enclosure model name. Corrective action: Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel.
MMB Messages 2.1.20 Maintenance mode related The messages related to the maintenance mode are listed below. CC6F00FF Enter Hot Maintenance Meaning: The hot maintenance mode is activated. Corrective action: No action is necessary. Severity: Info CC6F01FF Enter Partition Maintenance (In case PRIMEQUEST 2400E2/2800E2/2400E/2800E) Enter Hot Maintenance (In case PRIMEQUEST 2800B2/2800B) Meaning: The partition maintenance mode is started.
MMB Messages 2.1.21 Power Saving related The messages related to the power saving are listed below. CD6F01FF Power Saving Started Meaning: The power is actually saved by power saving function. The performance of device may be limited. Corrective action: No action is necessary. Severity: Info CDEF01FF...
Page 90
MMB Messages C8A7B1001 PCIe SSD Card Temperature above error threshold (VendorID=%04x DeviceID=%04x SubvendorID=%04x Subsystem=%04x) on IOU_%dGbE Capacity=%s Meaning: Temperature has exceed the upper error threshold. Corrective action: Reduce the load of writing operations. Check the ambient temperature and system environment as well. Severity: Warning C8A7B1002...
Page 91
MMB Messages E76F0900 SSD Rated Write Endurance has reached 30% (PCI_Box or IOU#n-Slot#n-Port#n, Cascade#, %s) %s: Disk enclosure model name (e.g. “JX40”) Meaning: SSD Rated Write Endurance has reached 30%. Corrective action: No action is necessary. Severity: Info E76F0901 SSD Rated Write Endurance has reached 30% Meaning: SSD Rated Write Endurance has reached 30%.
MMB Messages E76F0906 SSD Rated Write Endurance has reached 80% (PCI_Box or IOU#n-Slot#n-Port#n, Cascade#, %s) %s: Disk enclosure model name (e.g. “JX40”) Meaning: SSD Rated Write Endurance has reached 80%. Corrective action: Please prepare the replacement part of SSD. Severity: Info E76F0907 SSD Rated Write Endurance has reached 80%...
MMB Messages 2.2.1 Linux related ■LAN, FC (Linux) related 11001 Adapter error (should not be a VF) Meaning: An invalid VF device ID was set for PCIe SR-IOV capability. Corrective action: An adapter failure may have occurred. Replace the adapter. Severity: Warning 11601...
Page 94
MMB Messages 11612 Adapter error (failed STATUS register test) Meaning: The STATUS register test failed. Corrective action: An adapter failure may have occurred. Replace the adapter. Severity: Warning 11615 Adapter error (Cannot do PHY loopback test when SoL/IDER is active.) Meaning: The PHY loopback test cannot be executed.
Page 95
MMB Messages 11712 Adapter error (failed STATUS register test) Meaning: The register test failed. Corrective action: An adapter failure may have occurred. Replace the adapter. Severity: Warning 11715 Adapter error (Cannot do PHY loopback test when SoL/IDER is active.) Meaning: The PHY loopback test cannot be executed.
Page 96
MMB Messages 11815 Adapter error (ixgbe_up failed after reset) Meaning: After a reset, the card could not work well. Corrective action: An adapter failure may have occurred. Replace the adapter. Severity: Warning 11816 Adapter or Software error (HW Init failed) Meaning: Initialization of hardware failed.
Page 97
MMB Messages 11826 Adapter error (failed STATUS register test) Meaning: The STATUS register test of the NIC failed. A hardware error occurred. Corrective action: High probability of an adapter failure. Proceed to adapter replacement Severity: Warning 11827 Adapter error (Could not enable Tx Queue) Meaning: The transmit queue cannot be enabled.
Page 98
MMB Messages 11850 Adapter error (ixgbe Failed to allocate MSI-X interupts) Meaning: Allocation of MSI-X interrupts is failed. Corrective action: High probability of an adapter failure. Proceed to adapter replacement. Severity: Warning 12005 Device or FC-Network error (Nodev timeout) Meaning: The driver lost the connection destination(A device lost time-out occurred).
Page 99
MMB Messages 12027 Adapter error (Config Port initialization error) Meaning: A READ_NVPARM mailbox command failed during initialization of the adapter. Corrective action: Hardware or firmware has a fault. If the error keeps recurring, contact your sales representative or a field engineer.
Page 100
MMB Messages 12034 Adapter error (Adapter failed to init; mbxCmd CONFIG_PORT) Meaning: Initialization of the adapter failed. Corrective action: Hardware or firmware has a fault. If the error keeps recurring, contact your sales representative or a field engineer. Severity: Warning 12035 Adapter error (Adapter failed to init;...
Page 101
MMB Messages 12064 Adapter error (Suspect any fixed hardware failure) Meaning: An HBA reset was tried after a parity error was detected, but the operation ran out of retries. The HBA is blocked.(PC error recovery) Corrective action: An HBA or a PCI bus in the system has a fault. Replace the adapter. Severity: Warning 12070...
Page 102
MMB Messages 12091 Adapter error (Adapter failed to set maximum DMA length mbxStatus) Meaning: Adapter initialization failure. Corrective action: No action is necessary. Severity: Warning Remark: This error is not detected after SVAS/SVAgent V7.10-16. This error is detected before SVAS/SVagent V7.10-14, but corrective action is not needed. 12222 Adapter error (HBA Unrecoverable error) Meaning:...
Page 103
MMB Messages 12454 Adapter error (Unrecoverable error detected in the adapter) Meaning: Unrecoverable error occurred in the adapter. Corrective action: Reboot the Partition. If the error keeps recurring, replace the adapter. Severity: Warning 12455 Adapter error (Please upgrade firmware) Meaning: Upgrade of firmware is needed.
Page 104
MMB Messages 12556 Adapter error (Hardware Initialization Failed) Meaning: Hardware is not initialized or not working correctly. Corrective action: Replace the HBA Severity: Warning 12557 Adapter error (OSM Hardware Initialization Failure) Meaning: Hardware is not initialized or not working correctly. It might be a firmware problem. Corrective action: Replace the HBA Severity:...
Page 105
MMB Messages 13009 Adapter error (pci-resume: Cannot recover) Meaning: A resume operation on the adapter failed. Corrective action: The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer. Severity: Warning 13011 Adapter error (Adapter not ready) Meaning: The adapter does not become READY.
Page 106
MMB Messages 13022 Adapter error (Wait IOC_READY state timeout) Meaning: The state did not change to IOC_READY even after a wait for the specified time (15 seconds). Corrective action: The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer. Severity: Warning 13023...
Page 107
MMB Messages 13031 Adapter error (ResetHistory bit failed to clear) Meaning: The ResetHistory bit of the adapter could not be cleared. Corrective action: The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer. Severity: Warning 13032...
Page 108
MMB Messages 13049 Adapter error (IOC says it doesn't support F/W download) Meaning: A response that invalidates the download request sent to firmware was received. (Firmware download is not supported.) Corrective action: The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer. Severity: Warning 13050...
Page 109
MMB Messages 13120 Adapter error (detects pci parity error) Meaning: A parity error occurred during reading to PCI. Corrective action: The HBA must be replaced. If the problem persists even after you replace the HBA, replace the device (e.g., PCI_Box) connected to the HBA. Severity: Warning 13121...
Page 110
MMB Messages 13129 Adapter error (Sending IOCInit failed) Meaning: The MPT request/reply wait process for the adapter failed. Corrective action: The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer. Severity: Warning 13130 Adapter error (Sending PortEnable failed) Meaning:...
Page 111
MMB Messages 13146 Adapter error (operation failed) Meaning: The SAS persistent operation failed. Corrective action: Collect the data for investigation (dump or fjsnap). Contact your sales representative or a field engineer. Replace the adapter. Severity: Warning 13147 Adapter error (Controller disabled) Meaning: The controller is not in the active state.
Page 112
MMB Messages 13177 Adapter error (reset failed) Meaning: The adapter reset failed. Corrective action: The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer. Severity: Warning 13181 Adapter error (mpt_fault_reset_work: HardReset) Meaning: The result of resetting the adapter is output.
Page 113
MMB Messages 13187 Adapter error (Firmware Reload FAILED) Meaning: The pointer value of the request frame is null or outside its range. Corrective action: The HBA must be replaced. If the error keeps recurring, contact your sales representative or a field engineer. Severity: Warning 13188...
Page 114
MMB Messages 13195 Adapter error (IOC Not operational) Meaning: The adapter is not in the operational state. Corrective action: Replace the target device. If the error keeps recurring, contact your sales representative or a field engineer. Severity: Warning 13196 Adapter error (Issuing HardReset) Meaning: The hardware will be reset.
Page 115
MMB Messages 13216 Adapter error (mpt_config timed out) Meaning: A config request to the adapter timed out during adapter reset processing. Corrective action: Replace the target device. If the error keeps recurring, contact your sales representative or a field engineer. Severity: Warning ■PCIe-SSD (Linux) related...
Page 116
MMB Messages 13905 Adapter error(Entering read-only mode) Meaning: The adapter entered read-only mode. Corrective action: Replace the adapter. Severity: Warning ■SCSI common (Linux) related 14016 Device error (Error with sense data) Meaning: An error with sense data occurred in the device. Corrective action: Check the sense key of the original data to decide on the corrective action.
Page 117
MMB Messages 14024 Device or Software error (Overrun) Meaning: A device or application error occurred. An overrun occurred on a variable-length device. Corrective action: If you were working on a DAT by using a command such as dd, confirm that the specified parameters are correct.
Page 118
MMB Messages 14061 Device error (SCSI command retry out) Meaning: A SCSI command terminated abnormally (retry out). Corrective action: Identify the type of the target unit. Then, check the sense key (extended sense) in the original message to determine the corrective action. 1 (Recovered Error): If it is a removable device, perform cleaning.
Page 119
MMB Messages 14072 Device error (Device configuration error) Meaning: An error occurred in the device configuration. Corrective action: If you need to use all LUNs, the external disk unit configuration must be changed. If you accept the fact that some of them will not be available, no action is necessary. Severity: Warning 14073...
Page 120
MMB Messages 14139 Device error (I/O error) Meaning: An I/O error occurred. Corrective action: If the return code is "0x00010000" a no-response error occurred on the disk. Replace the disk. If another return code is returned, identify the type of the target device from its host, id, and lun. Then, check the sense key (extended sense) to determine the corrective action.
Page 121
MMB Messages ■GLS (Linux) related 17001 Network error (poll fail retry over.polling stop) Meaning: A transmission path error occurred. Polling failed successively until the retry count reached the specified number. The HUB monitoring function will be disabled. Corrective action: Check the transmission path. After the normal operation of the transmission path is restored, disable and enable the HUB monitoring function.
Page 122
MMB Messages 17007 Network error (SecondaryHUB to PrimaryHUB polling failed.) Meaning: HUB-to-HUB monitoring on the secondary side failed. Corrective action: Confirm that the communication path to the monitoring target has no problems. Severity: Error ■IB (Linux) related 18013 Failed to init command interface Meaning: Initialization command failed.
Page 123
MMB Messages 18029 Failed to reset HCA Meaning: An error occurred during reset of HCA Corrective action: Replace IB HCA card. Severity: Error 18030 Failed to initialize Meaning: An error occurred during initialization. Corrective action: Replace IB HCA card. Severity: Error 18048 NOP command failed to generate interrupt...
Page 124
MMB Messages 19003 Adapter error (Write operations disabled) 800GB card Meaning: Write operations are disabled. Corrective action: It might be a temperature problem, power unit problem or life cycle problem etc... Contact your sales representative or a field engineer. Severity: Warning 19004 Adapter error (Memory is close to wearing out)
Page 125
MMB Messages 19051 Adapter error (Write performance reduced) 1.6TB card Meaning: Write performance is degraded. Corrective action: It might be a temperature problem, power unit problem or life cycle problem etc... Contact your sales representative or a field engineer. Severity: Warning 19052 Adapter error (Write operations disabled)
Page 127
MMB Messages 19105 Adapter error (Reliability degraded) 2.0TB card Meaning: The reliability is degraded. Corrective action: It might be a temperature problem, power unit problem or life cycle problem etc... Contact your sales representative or a field engineer. Severity: Warning 19106 Adapter error (Temperature above warning threshold) 2.0TB card...
Page 128
MMB Messages 19203 Adapter error (Temperature above warning threshold) 2.6TB card Meaning: Temperature exceeded the upper warning threshold. Corrective action: Reduce the load of writing operations. Check the ambient temperature and system environment as well. Severity: Warning 19250 Adapter error (Temperature close to error threshold) 5.2TB card Meaning: Temperature closed the upper error threshold.
MMB Messages 22127 Adapter error (Hardware initialization failed; failing driver load) Meaning: Hardware initialization is failed. Failed to load the driver. Corrective action: Replace the adapter. Severity: Warning 22132 Adapter error (Failed to map Base Address Register; failing driver load) Meaning: Failed to map Base Address Register, and then failed to load the driver.
Page 130
MMB Messages 21711 Adapter error (Not configured for bus mastering) Meaning: The adapter is not configured for bus mastering in the PCI BIOS. Corrective action: If the unit name is IOU#n-PCIC#n-FUNC#n or PCI_Box#n-PCIC#n-FUNC#n: >> Mount the adapter in a slot that supports bus masters. If the unit name is SB#n-NIC: >>...
Page 131
MMB Messages 21802 Adapter error (EEPROM error) Meaning: An error may have occurred in the EEPROM of the adapter. Corrective action: Replace the adapter. Severity: Error 21810 Adapter error (The fan on the network adapter has failed) Meaning: An adapter failure occurred. Corrective action: Turn off the computer, and replace the network adapter.
Page 132
MMB Messages 21863 Adapter error (overheated) Meaning: The network adapter has stopped because of overheating. Corrective action: Perform a restart. If the problem persists, turn off the computer, and replace the network adapter. Severity: Error 21902 Adapter error (EEPROM error) Meaning: An error may have occurred in the EEPROM of the adapter.
Page 133
MMB Messages 22126 Adapter error (Uncorrectable error detected) Meaning: An Uncorrectable error occurred. Corrective action: Check whether the driver is latest version. If it is latest version, replace the adapter. Severity: Warning 22127 Adapter error (Hardware initialization failed; failing) Meaning: Driver loading failed because of a hardware initialization failure.
Page 134
MMB Messages ■ MPD (Windows) related 25001 Adapter or FC-Network error (An input/output error has occurred) Meaning: An I/O error was detected. Corrective action: Check the device indicated by “Unit” and “Source” in SEL of MMB. Severity: Error 25002 Adapter or FC-Network error (An input/output error has occurred) Meaning: An I/O error was detected.
Page 135
MMB Messages 28717 Adapter error (Incompatible PCI slot bandwidth) Meaning: The PCI slot bandwidth is incompatible. Corrective action: If the error recurs, collect investigation materials (e.g., fjsnap, PrimeCollect), and contact your sales representative or a field engineer. Severity: Warning 28718 Adapter error (Write performance reduced) Meaning: Write performance decreased.
Page 136
MMB Messages 28723 Adapter error (Auxiliary voltage out of range) Meaning: The auxiliary voltage is outside its range. Corrective action: If the error recurs, collect investigation materials (e.g., fjsnap, PrimeCollect), and contact your sales representative or a field engineer. Severity: Warning 28724 Adapter error (Flashback error)
Page 137
MMB Messages 28729 Adapter error (Power loss protection disabled) Meaning: Power loss protection is disabled. Corrective action: Collect investigation materials (e.g., fjsnap, PrimeCollect), and contact your sales representative or a field engineer. Severity: Warning 28730 Adapter error (Write regulation activated due to power constraints) Meaning: Writing is restricted because of PCI slot power constraints.
Page 138
MMB Messages 28735 Adapter error (LEB map missing) Meaning: The LEB map was lost. Corrective action: Collect investigation materials (e.g., fjsnap, PrimeCollect), and contact your sales representative or a field engineer. Severity: Warning 28737 Adapter error (Reserves depleted) Meaning: Reserved areas have been depleted. Corrective action: Check the format size.
Page 139
MMB Messages 29012 Adapter error (Write operations disabled) 800GB card Meaning: Write operations are disabled. Corrective action: It might be a temperature problem, power unit problem or life cycle problem etc... Contact your sales representative or a field engineer. Severity: Warning 29013 Adapter error (Write operations disabled)
Page 140
MMB Messages 29060 Adapter error (Internal error) 1.6TB card Meaning: Internal error has occurred. Corrective action: Replace the PCIe-SSD card. Severity: Warning 29061 Adapter error (Write performance reduced) 1.6TB card Meaning: Write performance is degraded. Corrective action: It might be a temperature problem, power unit problem or life cycle problem etc... Contact your sales representative or a field engineer.
Page 141
MMB Messages 29066 Adapter error (Temperature above warning threshold) 1.6TB card Meaning: Temperature exceeded the upper warning threshold. Corrective action: Reduce the load of writing operations. Check the ambient temperature and system environment as well. Severity: Warning 29067 Adapter error (Adapter removed) 1.6TB card Meaning: Adapter is removed.
Page 142
MMB Messages 29114 Adapter error (Memory is close to wearing out) 2.0TB card Meaning: The product lifetime end for write operation will come soon. If the device is still used, it will be switched to the Read-Only mode, and then the data will NOT be written to the device anymore. Corrective action: Replace the PCIe-SSD card to the new one which is already purchased.
Page 143
MMB Messages 29202 Adapter error (Flashback error) 2.6TB card Meaning: Flashback error is occurred. Corrective action: Back up the data from the affected PCIe SSD. Replace the PCIe SSD as soon as possible, restore the data. Severity: Warning 29203 Adapter error (Temperature above warning threshold) 2.6TB card Meaning: Temperature exceeded the upper warning threshold.
MMB Messages List of CLI messages This section lists the messages related to the CLI. Are you sure you want to add %s to Partition#%d? [Y/N]: Meaning: Confirmation as to whether SB, IOU or Extended Partitioning is to be added to the partition Corrective action: No action is necessary.
Page 145
MMB Messages The specified SB#x is not supported. Meaning: The command cannot be performed in the specified SB. Corrective action: Confirm that the SB is correctly specified. Also confirm the configuration of the partition. Severity: Warning Unable to add the specified SB#x to the partition due to CPU mismatch between SBs. Meaning: The specified SB cannot be added as there is CPU mismatch between the SBs.
Page 146
MMB Messages Partition#x does not include the [SB#x | IOU#x | Extended Partitioning#x]. Meaning: The specified [SB | IOU | Extended Partitioning] is not included in Partition#x. (In the execution of the set partition home command, only the SB pattern emerges) Corrective action: Confirm that the SB | IOU | Extended Partitioning is correctly specified.
Page 147
MMB Messages Unable to power off the Partition#%d. Meaning: Partition#x cannot be powered Off. Corrective action: Try setting again. If it fails, contact your sales representative or a field engineer. Severity: Error Unable to force power off on the Partition#%d. Meaning: Partition#x cannot be forcibly powered Off.
Page 148
MMB Messages Unable to power on the partition (s) because the partition which does not have authority to you is included in the specified parameter. Meaning: The Partition Operator has issued a power On instruction for a partition which is not within the scope of management.
Page 149
MMB Messages The specified date is invalid. Meaning: The format of the specified date is invalid. Corrective action: Check the command parameter. Severity: Warning Unable to set date because NTP is enabled. Meaning: The set date command cannot be executed since the NTP is enabled,. Corrective action: Disable the NTP when executing the set date command.
Page 150
MMB Messages The specified port number is invalid. Meaning: The specified port number is invalid. Corrective action: Check the command parameter. Severity: Warning The specified port number is duplicated. Meaning: The specified port number is already registered. This port number cannot be registered. Corrective action: Check the command parameter.
Page 151
MMB Messages Failed to execute %s command. Meaning: The CLI command has terminated abnormally. Corrective action: If another message is output, see the message. Try setting again. If it fails, contact your sales representative or a field engineer. Severity: Error Failed to execute set partition command.
Page 152
MMB Messages Succeed to set partition name command. Meaning: The set partition name command has terminated normally. Corrective action: No action is necessary. Severity: Info Failed to execute set partition name command. Meaning: The set partition name command has terminated abnormally. Corrective action: If another message is output, see the message.
Page 153
MMB Messages ; is invalid character Meaning: “;” is an invalid character. Corrective action: Check the command parameter. Severity: Warning url is length over Meaning: Unable to process since the length of the URL exceeds the specified value (128Byte). Corrective action: Check the command parameter.
Page 154
MMB Messages Unified Firmware Version: XX, update status: updating YY% Meaning: Number of unified versions: XX, the firmware updating is in progress YY% Corrective action: No action is necessary. Severity: Info Unified Firmware Version: XX, update status: failed Meaning: Number of unified versions:XX, firmware update has failed. Corrective action: Check the System Event Log for errors, and try updating the firmware again.
Page 155
MMB Messages invalid passwd Meaning: An invalid character has been used in the password. Corrective action: Check the command parameter. Severity: Warning password needs 8 characters at least Meaning: At least eight characters are required in the password. Corrective action: Check the command parameter.
Page 156
MMB Messages Error: The checksum of the firmware file is invalid. Meaning: Checksum error has occurred in the firmware. Corrective action: Check the specified file. Severity: Error Error: The size of the firmware file is invalid. Meaning: The firmware file size is invalid. Corrective action: Check the specified file.
Page 157
MMB Messages Unable to execute the update. Standby MMB is fault or disable. Meaning: The firmware cannot be updated, since there is a fault in the standby MMB. Corrective action: Replace the standby MMB and then update the firmware. Severity: Warning The firmware is being updated now.
Page 158
MMB Messages No more User addition. Meaning: Unable to add a user beyond this, as the maximum number of registered users has been exceeded. Corrective action: Add the registration after deleting necessary users. Severity: Error No more Community addition. Meaning: The Community cannot be added beyond this, as the maximum number of registered Community exceeded.
Page 159
MMB Messages The DIMM does not satisfy requirements of the Mirror Mode. If you register the specified SB%s as a Reserved SB, the Mirror Mode will be disabled when switching to specified SB. Are you sure to continue? [Y/N] Meaning: An attempt was made to set the Mirror Mode for a partition in which the SB, with a DIMM configuration that does not meet the SB requirement, has been assigned as a Reserved SB.
Page 160
MMB Messages The SB with DIMM that does not satisfy requirements of Mirror Mode is registered as a Reserved SB. If you register this partition as a Mirror Mode, Mirror Mode will be disabled when switching to Reserved SB. Are you sure to continue? [Y/N] Meaning: An SB containing a DIMM that does not satisfy the requirements of a Mirror Mode has been assigned as a Reserved SB.
Page 161
MMB Messages Command Failed Code=aa, bb Meaning: The update command has terminated abnormally. aa :Exception code bb :Action code Corrective action: If there is another message which has been output, refer the message. Try setting again. If it fails, contact your field engineer.
Page 162
MMB Messages Failed to ntpq command. Meaning: The show ntpq command process has failed. Corrective action: Retry the process; if it fails, contact your sales representative or a field engineer. Severity: Error Unable to execute this command because Extended Partitioning mode of the Partition#x is Enabled. Meaning: This process cannot be executed for a PPAR partition in which the setting of the Extended Partitioning mode has been enabled.
Page 163
MMB Messages Unable to set configuration because this Extended partition is powered on. Meaning: Unable to change the Extended Partition configuration, because the partition is the powered on status. Corrective action: Change the Extended Partition configuration after turning off the partition power of the partition. Severity: Warning The specified [CPU Cores | Memory|USB1 | VGA/USB2 | PCI Slot] is not free.
Page 164
MMB Messages Partition#x does not include the specified [GBE | PCI SLOT | DU]. Meaning: The specified [GBE IPCI SLOT IDU] is not included in the Partition. Corrective action: Check the Partition configuration. Severity: Warning Partition#x does not include the specified [PCI BOX | PCI SLOT]. Meaning: The specified [PCI BOX I PCI SLOT] is not included in the Partition.
Page 165
MMB Messages DR operation start (1/5) Meaning: DR operation of SB is started. Corrective action: No action is necessary. Assigning SB#$ to partition#$ (2/5) Meaning: The allocation to the partition is executed. Corrective action: No action is necessary. Testing SB#$ (3/5) Meaning: The diagnosis to the partition is executed.
Page 166
MMB Messages Unable to execute DR command because OS is not ready for DR operation Meaning: The DR command cannot execute because OS of the specified partition is not ready. Corrective action: Please wait for OS booting. In case of OS running, please confirm OS supports the DR function and the method of installing OS is correct.
Page 167
MMB Messages Unable to power off the DR test partition Meaning: Power of the DR test partition cannot turn off. Corrective action: Retry the process. If it fails, contact your sales representative or a field engineer. Hot-add [SB#$|IOU#$] failure Meaning: Hot-add SB/IOU cannot execute because there is Error or Warning of the specified SB/IOU.
Page 168
MMB Messages DR sequence timeout: SB hot-add OS failure Meaning: Timeout of DR sequence occurred in OS processing. Corrective action: Please deal with it according to SEL and syslog of OS. DR sequence timeout: SB hot-add request failure Meaning: Timeout of DR sequence occurred in adding of SB. Corrective action: Confirm SEL.
Page 169
MMB Messages The specified SB#$ is home SB. Meaning: The specified SB cannot remove because it is Home SB in the partition. Corrective action: Please confirm configuration of partition. The specified [SB#$|IOU#$] is not in specified Partition. Meaning: The specified SB cannot remove because it is not constituent of the partition. Corrective action: Please confirm configuration of partition.
Page 170
MMB Messages Removing [SB#$|IOU#$] from Partition#Z, Failed. Meaning: Removing of SB/IOU is failed. Corrective action: Please deal with it according to other messages output at the same time Unable to execute power control because the firmware is updating. Meaning: Power control cannot execute because the firmware is updating. Corrective action: Wait for completing of firmware update.
MMB Messages Unable to set Extended Partitioning Mode because Extended Partitioning doesn't support multiple SB configuration except SB#0-1 or SB#2-3. Meaning: For unsupported configuration, Extended Partitioning Mode can't be enabled. Corrective action: Please confirm configuration. Severity: Warning Unable to set Extended Partitioning Mode because Extended Partitioning doesn't support Reserved SB in multiple SB configuration.
Page 172
MMB Messages E_00012 One or more errors occurred while setting. Meaning: Error has occurred while setting. Corrective action: Retry the process. If it fails, contact your sales representative or a field engineer. Severity: Error I_00013 Setting completed. Meaning: Setting was successful. Corrective action: No action is necessary.
Page 173
MMB Messages E_00022 The partition doesn't have a node. Meaning: There is no node in the selected partition. In case of Remove: • Displayed when a partition is selected to remove a node, and all nodes have been removed by another user. •...
Page 174
MMB Messages E_00036 Changing Password failed. Meaning: Password change has failed. Displayed when the original password that was entered is incorrect. Corrective action: Enter the correct Password. Try to change again; if it fails, contact your administrator. Severity: Error I_00037 Changing Password completed.
Page 175
MMB Messages I_00046 Importing has completed. Meaning: Import has been completed. Corrective action: No action is necessary. Severity: Info E_00047 Importing failed. Meaning: Importing has failed. Displayed when import of an SSL has failed. Corrective action: If the problem persists even after importing again, contact your sales representative or a field engineer. Severity: Error E_00048...
Page 176
MMB Messages E_00057 Specified file cannot restore. Meaning: The entered file is outside the restoration target. The file specified as the restoration target is not the MMB (BIOS) configuration information backup file. Corrective action: Specify the correct file. Severity: Error W_00068 There are no available units on which maintenance can be performed.
Page 177
MMB Messages E_00079 Partition#%aa command failed. Meaning: Setting the power control command for Partition#%aa has failed. Corrective action: Check the partition status. Severity: Error E_00080 Partition#%aa cannot execute Power Cycle. Meaning: Power Cycle cannot be executed for Partition#%aa. Corrective action: Check the partition status.
Page 178
MMB Messages E_00091 Force Power Off Delay setting failed. Meaning: Setting the Force Power Off Delay in the Setup information has failed. Corrective action: Check the partition status. Severity: Error I_00095 The standby MMB is rebooting now. Please wait several minutes. Meaning: Standby MMB has started rebooting.
Page 179
MMB Messages E_00109 Unable to force power off. Meaning: Force Power Off cannot be executed in the present state. Corrective action: Wait for some time and execute Force Power Off again. Severity: Error E_00110 [PRIMEQUEST2800B2/2800B] Failed to add the SB or IOU to the partition. Meaning: Addition of SB or IOU to the partition has failed.
Page 180
MMB Messages E_00113 Unable to register the specified SB#%aa as a Reserved SB due to CPU mismatch between SBs. Meaning: SB#%aa cannot be registered, because there is mismatch of CPUs that are mounted between the SBs. Corrective action: Make sure that the CPU mounted on the SB configuring the partition, is the same as the CPU to be mounted on the Reserved SB.
Page 181
MMB Messages I_00202 Another user is currently performing maintenance. Please release Maintenance Mode if you still want to proceed. Meaning: Another user is performing the maintenance. Release the maintenance mode before proceeding with the operation. Corrective action: Release the maintenance mode before proceeding. Severity: Info I_00203...
Page 182
MMB Messages I_00206 Please select a maintenance mode. Meaning: Select a maintenance mode. Corrective action: Select a maintenance mode. Severity: Info W_00206 Maintenance of this unit cannot be performed because the unit does not satisfy requirements of any of the maintenance modes. Please check that the power status of partitions is Standby in the Partition Power Control Window, and that there is available free units in the Partition Configuration Window.
Page 183
MMB Messages W_00208 The power status of one of the partitions is now On. The selected Maintenance Operation Mode has become unavailable. Please check that the power status of partitions is Standby in the Partition Power Control Window. Then please try again. Meaning: After Warm System Maintenance or Cold System Maintenance is selected and the [Next] button is clicked, if the power status of the target partition has been changed due to a user operation, ‘Maintenance cannot be...
Page 184
MMB Messages I_00211 Log files have not been saved. Are you sure you want to continue? Meaning: The confirmation window appears when the [Next] button in the log saving window is clicked without saving the log data, asking whether to proceed to the next window without saving the log files. Corrective action: If the log files need not be saved, click the [OK] button to proceed to the next window.
Page 185
MMB Messages W_00214 Unable to power on the Partition#%aa due to CPU mismatch between SBs. After checking SB status and configuration, please come back to the Replacement Instruction Window, and reinstall the unit. Meaning: During the power-on process of partition#%aa in SB Warm System Maintenance, the power to the partition could not be turned on because of mismatching CPUs between the SBs.
Page 186
MMB Messages W_00217 The unit powering on has been skipped because chassis power status is currently off. After Maintenance completion, Check the System Event Log Window to refer to the error details. Meaning: The power of the unit cannot be turned on because the system (cabinet) power is off. Corrective action: The power-on process was skipped, however, continue the operation.
Page 187
MMB Messages I_00220 Unable to set Home on Partition#%aa because this partition is under maintenance. Meaning: Home cannot be set on Partition#%aa since it is under maintenance. Corrective action: Wait until the maintenance work is completed and maintenance mode is released. Severity: Info I_00221...
Page 188
MMB Messages I_00225 Unable to execute %aa Firmware Update on %bb because %cc is not under maintenance. Meaning: The firmware cannot be updated for the %aa firmware update target %bb, because %cc is under maintenance. Corrective action: Set the maintenance mode. Severity: Info W_00225...
Page 189
MMB Messages I_00230 Unable to execute MMB Firmware Update during %aa. Meaning: MMB firmware cannot be updated because it is %aa. Corrective action: Set the appropriate maintenance mode, or execute the update if it is not under maintenance. Severity: Info I_00231 Unable to execute MMB Firmware Update because a partition is powered on.
Page 190
MMB Messages I_00236 The %aa firmware update has been completed successfully. Meaning: This message appears when the specified firmware has been updated successfully. ‘The firmware of %aa has been successfully updated’ is notified. Corrective action: No action is necessary. Severity: Info W_00236 Failed to switch Location LED on, but maintenance will still continue.
Page 191
MMB Messages W_00238 Specified file is not a firmware file. Please select a valid firmware file. Meaning: The file specified for the firmware update process is not a firmware file. Corrective action: This window is displayed again when the [OK] button is clicked. Specify the correct firmware file. Severity: Warning W_00239...
Page 192
MMB Messages W_00246 The %aa firmware update has been failed. Please retry to update the firmware. After Maintenance completion, Check the System Event Log Window to refer to the error details. Meaning: The %aa firmware update process has terminated abnormally. Corrective action: This window is displayed again when the [OK] button is clicked.
Page 193
MMB Messages E_00305 Maintenance cannot be continued because PCI_Box FAN Speed Mode could not be set to high-speed. Check the System Event Log Window to refer to the error details. Meaning: The PCI_Box FAN high-speed setting process executed in Hot System Maintenance / Warm System Maintenance has terminated abnormally.
Page 194
MMB Messages E_00313 Maintenance cannot be continued because the MMB#%aa is in Failed status. Check the System Event Log Window to refer to the error details. Meaning: The operation cannot continue because MMB#%aa had started in the Fail state. Corrective action: The completion window appears when ‘OK’...
Page 195
MMB Messages W_00404 Password differs from the re-password. Meaning: The entered two passwords (or pass phrases) do not match with the changed password and confirmed password. Corrective action: Check the Password. Severity: Warning W_00406 Invalid character is included in User Name. Meaning: The user name includes an invalid character.
Page 196
MMB Messages I_00411 %aa will be changed. Are you sure? Meaning: User% aa will be changed. The message asks for confirmation to continue processing. Corrective action: No action is necessary. Severity: Info E_00412 You need an empty entry. Meaning: ‘Add’ was specified, but further schedules cannot be registered. Displayed when a schedule is added when the registered schedule data has reached the upper limit of registration.
Page 197
MMB Messages E_00419 Unable to register the specified SB#%s as a Reserved SB due to unsupported CPU configuration. Meaning: The specified SB cannot be registered as a Reserved SB, because the CPU does not meet the mounting criteria. Corrective action: Check the status of the CPU mounted on the SB.
Page 198
MMB Messages E_00425 Unable to add the specified SB to the partition due to DIMM composition abnormal. Meaning: The specified SB cannot be added to the partition since there is an error in the DIMM configuration. Corrective action: Place the SB mounted DIMM in such a way that it meets the Mirror Mode requirements. Severity: Error W_00426...
Page 199
MMB Messages W_00432 Invalid IP Address specified. Meaning: The IP address is invalid. Displayed if an invalid IP address is specified. Corrective action: Check the IP address. Severity: Warning W_00433 The duplicate IP address was found. Meaning: The IP address has been duplicated. Corrective action: Check the IP address.
Page 200
MMB Messages E_00439 SSL Server Certificate is not found. Meaning: The server certificate for use in the HTTPS is not found. Corrective action: Set the HTTPS after installing the certificate. Severity: Error I_00440 HTTP Connection will be lost. You will need to login again. Are you sure? Meaning: Disabling the HTTP (HTTPS) will disconnect the Web-UI.
Page 201
MMB Messages W_00448 CSR doesn't exist. Meaning: CSR not registered. Displayed when an attempt is made to Export without registering the CSR. Corrective action: Register the CSR. Severity: Warning W_00449 A certificate file is not selected yet. Meaning: The certificate file has not been selected. Corrective action: Specify a certificate file and import.
Page 202
MMB Messages W_00456 Invalid E-Mail address format. Meaning: The e-mail address format is incorrect. Corrective action: Check the e-mail address. Severity: Warning W_00457 Invalid SMTP server address. Meaning: The SMTP server format is incorrect. Corrective action: Check the SMTP server name. Severity: Warning I_00458...
Page 203
MMB Messages W_00463 Select a User Name. Meaning: Select the target user to be edited or deleted. Corrective action: Select the target user. Severity: Warning I_00464 %aa will be removed. Are you sure? Meaning: User% aa will be deleted. The message asks whether to continue the process. Corrective action: Not required.
Page 204
MMB Messages I_00469 The settings for the Virtual IP Address are changed. All existing network connections about this settings will be lost. You will need to login again. If you want to continue, please click OK button. If not, click Cancel button. Are you sure? Meaning: When the Virtual IP is set, the currently connected network connections will be disconnected.
Page 205
MMB Messages W_00476 Unable to execute the online update. Please try the update after the system power off. Meaning: Unable to execute the firmware update because the system power is on. Corrective action: Retry the update after turning off the power of all the partitions. Severity: Warning W_00477...
Page 206
MMB Messages E_00491 Unable to power on the partition#%d due to DIMM does not satisfy requirements of Mode. Meaning: Unable to power on the partition #%d because the DIMM is in a configuration that does not meet the Memory Mode requirements. Corrective action: Check the location and mix status of the DIMM mounted on the SB.
Page 207
MMB Messages W_00496 Unable to power on the partition#%d due to CPU composition abnormal. After checking SB status and configuration, please come back to the Replacement Instruction Window, and reinstall the unit. Meaning: Partition#% d cannot be powered on because there is a problem in the CPU configuration, Check the configuration of the SB, and retry the replacement process in the [Replacement Instruction] window.
Page 208
MMB Messages I_00501 The SB with DIMM that does not satisfy requirements of Mirror Mode is registered as a Reserved SB. If you register this partition as a Mirror Mode, Mirror Mode will be disabled when switching to Reserved SB. Are you sure to continue? Meaning: An SB containing a DIMM that does not meet the requirements of the Mirror Mode is allocated as a Reserved SB.
Page 209
MMB Messages E_00517 Unable to power on the partition#%d due to abnormal SB composition. Meaning: The partition cannot be powered on because of a problem in the SB configuration. Corrective action: Check the mix status of the SB configuring the partition. Severity: Error W_00518...
Page 210
MMB Messages W_00529 Unable to execute Firmware Update because the chassis information could not be retrieved. Meaning: Unified Firmware Update cannot be performed since the value of the FRU cannot be acquired. After completion of the maintenance work, execute Unified Firmware Update. Corrective action: Execute Unified Firmware Update after the maintenance work is completed.
Page 211
MMB Messages W_00545 Unable to change Extended Partition Configuration to Partition#%aa, because this partition is powered on. Meaning: The configuration of Extended Partition cannot be changed since the partition is powered on. Corrective action: Change the Extended Partition configuration after turning off the partition power. Severity: Warning W_00550...
Page 212
MMB Messages E_00582 Maintenance cannot be continued because an internal error occurred while waiting for status update. Please check the System Event Log Window to refer to the error details. Meaning: Internal problem occurred during the waiting process of status change Firmware Update can’t operate. Corrective action: The completed window is displayed if “OK”...
Page 213
MMB Messages W_00588 Unable to command power control because the power control operating. Meaning: Command can’t accept because the power control is operating. Corrective action: Please wait for the completion for power control operating. Severity: Warning W_00589 Unable to change Resources, because this partition is powered on Meaning: Command can’t accept because the partition is power on state Corrective action:...
Page 214
MMB Messages W_00597 A subnet differs from MMB IP address. When you change a setup of Console Redirection IP address or you change a subnet, please change MMB IP address first. Meaning: A subnet of Console Redirection differs from MMB IP address. Corrective action: Please change to a different IP address.
Page 215
MMB Messages E_00608 No more Group addition. Meaning: A group cannot be created, because the number of existing group is the maximum. Corrective action: If a new group is needed, delete an existing group. Severity: Error E_00609 Unable to change the status to Disable because the specified group is last Administrator. Meaning: The status is unable to change disable because the specified group is last Administrator.
Page 216
LDAP cannot be enabled, because LDAP User Group of the Admin privilege is not set. Corrective action: Make LDAP User Group with privilege of Administrator. For the detail of making of the LDAP User Group, refer to 1.4.4.2 [LDAP User Group List] window in the PRIMEQUEST 2000 series Operations Management Tool Reference (CA92344-0539). Severity:...
Page 217
MMB Messages W_00623 Unable to add SB#XX to Partition#YY because Extended Partitioning doesn't support multiple SB configuration except SB#0-1 or SB#2-3. Meaning: For unsupported configuration, SB can't be added in Extended Partitioning. Corrective action: Please confirm configuration. Severity: Warning W_00624 Unable to set Extended Partitioning Mode because Extended Partitioning doesn't support multiple SB configuration except SB#0-1 or SB#2-3.
Dynamic Reconfiguration Messages CHAPTER 3 Dynamic Reconfiguration Messages This section lists the DR messages and contains information on how to respond to them. Messages concerning incomplete system environment dr-util:ERR:101: No space left on device. Meaning: There’s no disk free space. Corrective action: Failed to gather information because the disk free space is insufficient.
Page 219
Dynamic Reconfiguration Messages dr-util:ERR:%d: <x>: invalid device is set. [%d: 210-214] Meaning: <x> is not a device that can be specified with “add“ Corrective action: The invalid device for “add“ operation was set to the argument. Please review the command argument and execute the command again.
Page 220
Dynamic Reconfiguration Messages dr-util:ERR:280: cpu<x>: device is already available. Meaning: cpu<x> is already available Corrective action: cpu<x> is already available. No action is necessary. dr-util:ERR:280: memory<x>: device is already available. Meaning: memory<x> is already available. Corrective action: memory<x> is already available. No action is necessary.
Dynamic Reconfiguration Messages dr-util:ERR:289: IOU<x>: device is already disabled. Meaning: IOU<x> is already unavailable Corrective action: IOU<x > that tried to be removed is already unavailable. Please confirm whether the slot number is wrong. dr-util:ERR:%d: Internal Error [%d: 300, 301] Meaning: Internal error occurred.
Page 222
Dynamic Reconfiguration Messages dr-util:ERR:406: cpu<x> status is invalid: offline Meaning: The state of added CPU<x> is invalid, so CPU<x> is disabled. Corrective action: Please gather the information for investigation by using "/opt/FJSVdr-util/sbin/dr report" on the partition side, and contact the technology of our company member dr-util:ERR:407: memory<x>...
Page 223
Dynamic Reconfiguration Messages dr-util:ERR:424: Failed to eject SB<x> with error <y>. Meaning: Failed to remove SB<x> with error number <y>. Corrective action: The remove of SB<x> failed because of the error <y>. Please try removing of SB again. When the improvement is not seen even if it executes it again, please gather the information for investigation by using "/opt/FJSVdr-util/sbin/dr report"...
Dynamic Reconfiguration Messages dr-util:ERR:%d: IOU<x> status is invalid: <y> [%d: 453, 454] Meaning: The status of IOU slot <X> is invalid. Corrective action: Failed to check the IOU<x> slot status. Please gather the information for investigation by using "/opt/FJSVdr-util/sbin/dr report" on the partition side, and contact the technology of our company member dr-util:ERR:%d: Internal Error [%d: 455, 456]...
Dynamic Reconfiguration Messages dr-util:ERR:%d: Failed to send IPMI Command: Completion [%d: 601, 603] Meaning: Failed to send IPMI Command Corrective action: The action in OS is unnecessary though there is a possibility that error information on IOU hot plug is not correctly notified to MMB.
Page 226
Dynamic Reconfiguration Messages dr-util:INFO:%d: Execute <x> user programs at <y> timing. [%d: 806,807] Meaning: <x> of collaboration programs will be executed at <z> timing. <z> represents “before“ or “after“ dr-util:INFO:808: Executed user programs at <x> timing. Meaning: Collaboration programs executed at <x> timing. <x> represents “before“ or “after“ dr-util:INFO:809: Added SB<x>.
Page 227
Dynamic Reconfiguration Messages dr-util:INFO:%d: Execute <x> user programs at <y> timing. [%d: 841, 842] Meaning: <x> of collaboration programs will be executed at <z> timing. <z> represents “before“ or “after“ dr-util:INFO:843: Executed user programs at <x> timing. Meaning: Collaboration programs executed at <x> timing. <x> represents “before“ or “after“ dr-util:INFO:844: Added IOU<x>.
sadump Messages CHAPTER 4 sadump Messages This chapter describes the sadump messages which are displayed in the console. sadump Message list Sadump messages are listed below ERROR: An error occurred at reading EFI Variables(xxx). Meaning: The configuration of sadump is broken. Corrective action: Set up sadump again.
Page 229
sadump Messages WARNING: The device DUMP_DEVICEn is a dump device of another system. Trying next device. Meaning: The n-th dump device is used for another system. Trying next device. Corrective action: Set up sadump again. WARNING: The device DUMP_DEVICE1,DUMP_DEVICE2,DUMP_DEVICE3 contains memory image. DUMP_DEVICEn will be overwritten.