1.0
Specifications
• Input Power:
• Current Draw:
2-Wire:
LED Off:
In Alarm; LED On:
4-Wire:
LED Off:
In Alarm; LED On:
• Standby Power:
• Coverage:
Broad (standard):
Barrier (optional):
Long Range (optional): 70 ft. by 10 ft. (21.4 m by 3.1 m)
• Sensitivity:
• Tamper:
• Temperature:
• Control Panel:
Requirements:
• Options:
Misalignment of the detector when using an optional
NOTE:
mounting bracket may reduce range and increase dead
zones.
Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security
Systems, Inc. Web site at:
datecodes/
Connects directly to the Multiplex Bus
of the Control Panel and optionally to
an auxillary 12 VDC source.
<350 μA draw on Mux Bus.
2 mA draw on Mux Bus.
<350 μA draw on Mux Bus.
0 mA draw on Aux. power.
<350 μA draw on Mux Bus.
3 mA draw on Aux. power.
There is no internal standby battery.
Connect to DC power sources capable
of supplying standby power if primary
power fails. For each hour of standby
time needed, 350 μAh are required.
For UL Listed Requirements, four
hours (1400 μAh) minimum are
required.
35 ft. by 35 ft. (10.7 m by 10.7 m)
35 ft. by 10 ft. (10.7 m by 3.1 m)
Selectable for Standard, Intermediate,
or High.
A tamper condition is signaled through
the Multiplex Bus and displays at the
keypads.
The
storage
and
temperature range is -20°F to +120°F
(-29°C to +49°C). For UL Listed
Requirements, the temperature range
is +32°F to +120°F (0°C to +49°C).
DS7400, DS7400X, or DS7400Xi
control panel with a DS7430 or
DS7436 multiplex expansion module.
The DS7400 and DS7400X require
ROM version 1.07 or greater. 9000
Series Control/Communicators with
D8125MUX Module installed.
B335 Low Profile Swivel Mount
Bracket, B338 Ceiling Mount Bracket,
OMB93-3* Barrier Mirror, OMLR93-3*
Long Range Mirror.
*Shipped in packages of three.
http://www.boschsecurity.com/
2.0
Control Panel Programming
Refer to the multiplex programming section of your Control Panel
Reference Guide for information on programming multiplex zones
for this device.
3.0
Mounting
Moving objects
Hot or cold air
directed onto
sensor
Address Switches
1 2
3
4
5
6
7
8
O
N
Tamper Switch
Program
Plugs
H
ON
I
S
OFF
Location of major items - Circuit Board
The mounting surface should be solid and vibration free.
IMPORTANT
operating
• Select a location that is most likely to intercept an intruder moving
across the coverage pattern. The recommended mounting height
range is 6.5 ft. to 8.5 ft. (2 m to 2.6 m).
• Remove the cover. Insert a thin flathead screwdriver into the
notch at the bottom of the cover and pry up.
• Remove the circuit board/mirror unit from the enclosure. Push
the board/mirror unit toward the top of the enclosure until it clears
its four retainer tabs, then lift it out.
• Open the knock-out wire entrance and route the wiring through.
3.1
Surface or Corner Mounting
• Open two holes for surface or corner mounting.
• Mark the location for the mounting screws. Use the enclosure
as a template. Pre-start the mounting screws.
• Securely attach the detector.
• Replace the circuit board/mirror unit.
• Select the Vertical Angle.
Mirror Information: The mirror is adjustable from +1° to -18° vertically
by sliding the mirror forward or back and ±10° horizontally by
rocking the mirror side to side. To change the mirror, just pull it out
from its resting grooves.
NOTE: Excessive handling of the mirror surfaces may lead to
performance degradation.
Avoid
Mounting Outdoors
Pets or animals
T-Strip
1
- + B- B+
Thinwall
Circuit Board Retainer Tabs
Knockout
for
Wiring
LED
1 = Corner 2 = Surface 3 = Bracket
Rear enclosure and mounting holes
Moisture
Direct or
reflected
sunlight
2
2
2
3
Mirror Tracks
2
1

Advertisement

loading

Summary of Contents for Bosch MX934i

  • Page 1 • Reading Bosch Security Systems, Inc. Product Date Codes NOTE: Excessive handling of the mirror surfaces may lead to performance degradation. For Product Date Code information, refer to the Bosch Security Systems, Inc. Web site at: http://www.boschsecurity.com/ datecodes/...
  • Page 2 Address Switch Settings • Set the address switch settings (see page 3) before connecting Only apply power after all connections have been made the MX934i to the multiplex bus. and inspected. POWER No two devices may be set to the same address. Having •...
  • Page 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 MX934i Installation Instructions Page 3 © 2011 Bosch Security Systems, Inc.
  • Page 4 Pattern Reference Meters Feet Side View Meters Feet Mirror adjusted to -2° View of Front Polished Surface 3/11 © 2011 Bosch Security Systems, Inc. MX934i Installation Instructions 130 Perinton Parkway, Fairport, New York 14450 P/N: F01U071219-07 Page 4 www.boschsecurity.com...