No.
91
Original Lead ADF
92
Original Trail ADF
93-98 Not Used
99
F5/F6 Initialization
4.1.6.
F7 Mode: Electronic Counter
Set the machine to Service Mode and press "7" key on the Keypad.
Press the "START" key.
Enter the desired code number or press "V", "/\" arrow keys.
Press the "SET" key.
Enter the desired function code number and press "SET" key.
When the "CLEAR" key is pressed, the selected code input will not be accepted.
Press "STOP" key, then press "FUNCTION" and "CLEAR" keys simultaneously to exit the service mode.
Reboot the machine after setting the parameter(s) to activate the setting(s).
No.
01
Key Operator ID Code
02
Total Count
03
PM Count
04
Scanner PM Count
05
Not Used
06
OPC Drum Count
07
Process Unit Count
08
ADF PM Count
09-10 Not Used
11
Sheet Bypass Count
12
1st Paper Tray Count
13
2nd Paper Tray Count
14-15 Not Used
16
2-sided Count
17
ADF Count
18
ADF Read Count
Ver. 2.0
Item
Adjustment of original detection timing.
Adjustment of trail edge detection timing.
Initialize F5/F6 parameter settings.
Item
F6 Mode
Remarks
F7 Mode
Key Operator's identification code for access to the
counter mode.
Total count for all copies / prints.
Preventive Maintenance count.
PM count for scanner readings.
PM count of recording paper fed through the OPC
Drum.
PM count of recording paper fed through the
Process Unit.
PM count of originals fed through the ADF.
Total count of paper fed from the sheet bypass.
Total count of paper fed from the 1st paper tray.
Total count of paper fed from the 2nd paper tray.
Total count of 2-sided Print.
Total count of originals fed through the ADF.
Total count of originals scanned through the ADF.