CARE AND
MAINTENANCE
MAIN UNIT
1
●
Poor insulation or rust may occur if the main unit gets wet.
NOTE
●
When using chemical agent, please follow the direction for use.
WHEN NOT USING FOR A LONG PERIOD OF TIME
AUTO
ECO
DEODORIZE
1
QUICK
CONTINUOUS
Beep
2
Drain outlet
Filter
3
Vacuum cleaner
Plastic bag
4
20
We recommend
periodical cleaning
for a long, clean and
(Continued)
sanitary use!
Once a month
Soak a soft cloth in
●
Wipe off any excessive detergent
lukewarm water
with a damp cloth thoroughly.
(40°C or lower) or
●
Do not forget to clean air inlet,
mild detergent to
air outlet, and casters as well.
wipe dirt off
Conduct internal
drying operation
Internal drying
(Laundry
●
Sometimes there are moistures on
deodorizing mode)
the cooler inside the main unit.
Run the laundry deodorizing
operation (air flow mode) for
about 2 hours.
(Using the OFF TIMER is useful)
This will dry the inside of main
unit and prevents mold from
Dispose water
forming.
Page 19
●
Take the tank lid off and wipe off
any water on the tank.
Clean the filter
Page 18
●
Put in the original box or place
Store in a dry
a cover (plastic bag) over the
unit to prevent dust and store.
place with no
●
If dust get in, the main unit may
direct sunlight
shoot out dust the next time it is
operated.
SPECIFICATIONS
Model
Power Supply
30°C/80%RH
Dehumidifying Capacity
26.7°C/60%RH
Power Consumption
26.7°C/60%RH
Standby Status
Dehumidification Area
Water Tank Capacity
Length of Power Cord
Dimensions
Weight
●
Dehumidifying Capacity: the amount of humidity that a dehumidifier removes from the air in a
day when room temperature and relative humidity are kept at 30°C/80%RH and 26.7°C/60%RH
respectively.
●
Power Consumption: the consumption value when fan speed reaches the highest.
●
Dehumidifying Area: according to standards of JEMA.
Standby Status: the power plug is pluged in the socket while the Power ON/Off button is set
at "Off".
DW-D20A
220V-240V/50Hz
20L/day
12.5L/day
270W
0.45W
25-50m
2
Approx. 4.2L
Approx. 1.8m
374mm(W)×250mm(D)×620mm(H)
About 15kg
21