Pioneer LISAS-B-1403 Service Manual page 108

Dc inverter split heat pumps
Table of Contents

Advertisement

Electrical Control Function
1.3.2.2 Outdoor fan running rules
For YN012GMFI16RUD and YN018GMFI16RUD:
For other models:
1.3.2.3 Indoor fan running rules
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto.
The auto fan:
For Console:
106
28
26
22
20
T4
A
28℃
26℃
B
25℃
23℃
C
22℃
20℃
D
19℃
17℃
E
3.5
3
1.5
1
High
Medium
Low
DC_FAN_HI_SPD_ADD
DC_FAN_MID_SPD_ADD
DC_FAN_MIN_SPD_ADD
DC_FAN_SLOW_SPD_ADD
DC_FAN_SSLOW_SPD_ADD
High
Medium
Low
Electrical Control System