Bosch DCN Next Generation 4.41 Release Notes page 12

Advertisement

DCN Next Generation Release Notes
Product/function
DCN-CCU(B)2
DCN-CONFF and
DCN-CONCM
DCN-SWSACC
and Allegiant
DCN-SWSACC
DCN-MR
DCN-MR
Multi CCU systems
Bosch Security Systems| 2014-10-31
Problem
Error relays activated
upon system reset or
firmware download.
DNPV answers in
voting are not visible
in the Concentus
screen when a voting
timer is activated.
Double screenlines
are still visible on
audience screens
after switching to
single screenlines.
Upload does not work
anymore.
DCN-MR does not
connect to DCN-SW
when installed on
another PC
Windows audio
playback is lost after
installation DCN-MR
1.3. in windows XP.
System reaction is
(very) slow after
system startup.
Solution
During a firmware download or system reset, the
system is not in normal operation and thus the error
relays can be active.
Use a hall display or disable the voting timer.
Restart the Allegiant.
Restart the DCN-CCU or DCN-NCO.
1. Open the Meeting Recorder.ini file with notepad
it is located here: C:\Users\[USER
NAME]\AppData\Roaming\Meeting Recorder
if the user name is administrator, the path will
be: C:\Users\
Administrator\AppData\Roaming\Meeting
Recorder
2. Find the variable NCO Ip=x.x.x.x (where x.x.x.x is
the IP address of DCN SW server) and below that
line;
Create a line DCO Ip=x.x.x.x (where x.x.x.x is the
IP address of the DCN SW server)
NCO Port=20000
NCO Ip=10.120.22.230
DCO Ip=10.120.22.230
CCU Ip=192.168.1.1
3. Save the Meeting Recorder.ini file
Replace files msacm32.drv, msadp32.acm and
imaadp32.acm in the windows system32 folder.
The system might become (very) slow when in a multi
CCU system only the NCO is switched off and the
rest of the system stays switched on.
To prevent this problem:
Shutdown all optical devices in the Multi-CCU system.