Pioneer DRM-6NX Service Manual page 36

Network cache changer
Hide thumbs Also See for DRM-6NX:
Table of Contents

Advertisement

DRM-6NX
6.2 ADJUSTMENT
6.2.1 HOW TO START/CANCEL TEST MODE
SERVICE REMOTE CONTROLLER
FUNCTION TABLE OF THE REMOTE CONTROLLER (RU-V101) FOR SERVICE
÷ Test Mode
Shows the function table of the remote controller (RU-V101) for service as follows. When operating the CD-ROM directly,
it is possible to operate as shown below by connecting the wired-remote control to the CD-ROM with the interface.
÷ Schematic Diagram of the Conversion Jig for Remote Control Operation
RU-V101
Interface
1
2
3
3P mini jack
Q1: DTC124ES or UN4212
TEST MODE : ON
Power Switch: ON
36
V +5V
10k
1
2.2k
REMI
2
3
Q1
GND
4
PH type
connector
(4P)
FUNCTION SW (S1001)
1 2 3
ON
TERM/ON
TEST MODE/ON
REAR PANEL
(IDSB BOARD ASSY)
CN13
1: VD5V
2: REMI
3: REMO
4: GNDD
CN13
1
4
TEST MODE 1
ID SW (S954)
0
SW POSITION: 1 to 7
REAR PANEL
(IDSB BOARD ASSY)
TEST MODE 2
ID SW (S954)
0
SW POSITION: 0 only
REAR PANEL
(IDSB BOARD ASSY)
MAIN BOARD ASSY
Power Switch: OFF