Electrical Diagram - Bosch 940 ESO Installation Manual

For outdoor installations only temperature modulated with electronic ignition suitable for heating potable water and space heating (intended for variable flow applications)
Hide thumbs Also See for 940 ESO:
Table of Contents

Advertisement

12

Electrical diagram

16
20
19
18
17
21
Fig. 60 Electrical scheme
1
Intlet water temperature sensor
2
Outlet water temperature sensor
3
Backflow temperature sensor
4
Cascading output connection
5
Cascading input connection
6
Ionization sensor
7
Water flow sensor
8
Flue gas limiter
9
Heat exchanger overheat sensor (ECO)
10
Gas valve
Jumper resistance
11
12
Water valve
13
Primary fan
ON/OFF switch
14
15
Secondary fan
16
AC plug
Main connection
17
18
Ignition electrodes
19
Ground post
20
Antifreeze kit connection
21
Fuse
22
Fuse
6 720 644 956
15
13
M
M
22
12
M
E
PS
T=104°C
T=220°F
20
...
16
...
1
14
JP2
JP8
JP7
JP6
JP5
6720608158-92.1AL
Electrical diagram
11
10
9
T=110°C
T=230°F
8
7
FS
6
Casc.
5
input
Casc.
output
Back flow
1
4
3
2
1