6. Possible faults and their removal.
5. Possible faults and their removal.
6.1 Do not flare up burners.
Faults
1. No fire.
3mm
2. Unstabl flame
3. Bad cooking
1. Check open valve of presenting
the gas.
2. There is gas in balloon.
3. Does Not outline gasmain.
4. Check the pressure of gas.
6.2 Flame appears and immediately go out.
Faults
1. The Flame go out after lower
handles of valve.
2. The Electromagenetic valve does
not operate.
2. The Electromagenetic valve is
faulty.
Removal
1. Check connecting of electric power.
2. Check contacts and wire
3. Check Spark plug.
4. Check clearance of contacts.
5. Clean Spark Contacts.
6. Check hole of burners.
7. Check air in gas' hose
8. Check sort of gas
1. Check assembling of cap burners
2. Check sort of gas
3. Check bending of Gas' hose
4. Check running out of gas
5. Check wind of around burners.
6. Check clearance of contacts.
1. Check chocking of duct.
2. Check assemble of Baffle oven.
3. Check pre heating time.
1. Open valve.
2. Change balloon.
3. Unbend gasmain.
4. Install pressure of gas.
Propane gas - 280±50mm H20
Natural gas - 200±50mm H20
Removal
1. Check the holes of leaving the gas
clean from water and strangers of
subject.
2. Check contacts and wire.
3. Change the electromagnetic valve.