4 Deployment Procedure

4.7 CS Registration

Notice
Connect each SIP-CS in the Air Sync Group to the network and turn them on.
During CS Registration, make sure that all unregistered SIP-CSs that are not in the Air Sync Group
you are registering are turned off.
Confirming the MAC addresses of all the SIP-CS
To register SIP-CSs to the Air Sync Master CS, the MAC address of each SIP-CS is required.
The MAC address is written on the rear side of each SIP-CS. Confirm the MAC address of each SIP-CS before
registering it.
Before registering
For the Super Master CS
Provide a static IP address which can be used on your network.
For details, refer to "Assigning IP Address Information" in "4.6 Basic Network Configuration".
For Air Sync Master CSs other than Super Master CS
Set the IP address of the Super Master CS.
Set the IP address type (DHCP or Static)
For Slave CSs
Set the IP address type (DHCP or Static)
For SIP-CSs that have been used before
Initialise the SIP-CS to restore settings to their factory defaults.
1.
Turn on the SIP-CS.
2.
Press and hold the RESET switch until the LED turns off (about 10 seconds).
Note
After initialising the SIP-CS, configure network settings if necessary. For information about
configuring network settings, see "4.6 Basic Network Configuration".
46
Installation Guide
Master CS
(Site Survey Mode)
PoE Hub
: Ethernet Cable
: Air Synchronisation

Hide quick links: