11.0 Network Communications

The Conettix D6600 and D6100i Communications
Receiver/Gateway systems support data network
communications. This allows the receiver to connect
to Ethernet networks, and process messages to and
from most networks in user datagram protocol (UDP)
or internet protocol (IP). Use a COM4 or a COM1
connection from the D6600 to connect the D6680 to
the network. The D6100i has a built-in Ethernet
module that can connect directly to the network. Refer
to Conettix D6600/D6100i Network System Guide
(P/N: 4998122712) for configuration setup
Instructions. Central station automation software,
through a local-area network (LAN) or wide-area
network (WAN), receives reports from alarm control
panels from the PSTN, or other data networks. The
automation software also monitors the control panel
status and connection over the network. Update or
upgrade the receiver through the network connection.
Use the D6200 software for remote programming of
the receiver. Refer to the following documents about
network communications and their installation
requirements.
Conettix D6600/D6100i Network System Guide
(P/N: 4998122712)
D9133TTL-E Installation Guide
(P/N: 4998122717)
C900V2 Installation Guide (P/N F01U003472)
C900TTL-E Installation Guide (P/N: 4998122718)
DX4020 Installation Guide (P/N: F01U045288)
D6680 Ethernet Network Adapter Installation
Guide (P/N: 4998138732)
DeviceInstaller Operation and Installation Guide
(P/N: 4998138688)
26
Network Communications
Figure 15: Conettix Network System
Connection Diagram - C900TTL-
E/C900V2 and Any Control Panel
2
3
1
P A N E L
1 2 3
4 5 6
7 8 9 1 0
O
F F
T E L C O
15
11
14
12
1 – Any manufacturer's control panel
2 – Connection - Control panel telco jack to
C900TTL-E jack
3 – C900TTL-E/C900V2 Dialer Capture Module
4 – Connection - C900TTL-E/C900V2 Ethernet
jack to Ethernet hub
5 – Host PC running D6200 Programming
Administrative Software
6 – Connection - Host PC network interface card
(NIC) to Ethernet hub
7 – Ethernet hub
8 - Connection – Ethernet hub to D6100i
9 - D6100i
10 – Connection – Ethernet hub to D6680
11 – D6680
12 – Connection – D6680 to D6600 COM4 port
13 – D6600
14 – Connection – Second D6680 to D6600 COM 1
port (optional)
15 – Connection – Ethernet hub to second D6680