Electrolux EN18WI30LS Service Manual page 41

Gas water heater
Hide thumbs Also See for EN18WI30LS:
Table of Contents

Advertisement

CAUTION
* Damage can occur from frozen water within the device and pipes even in warm environments.
Be sure to read below for appropriate measures.
* Repairs for damage caused by freezing are not covered by the warranty.
Freezing is prevented within the device automatically by the freeze-prevention heater.
Freezing cannot be prevented when the power plug is unplugged. Do not remove the power
plug from the wall outlet.
Freezing will be prevented regardless of whether the operation switch is ON or OFF.
* In normal operation, freezing is prevented within the device automatically unless the outside
temperature without wind is below -30°F (-35°C) for EN18WI30LS, EP18WI30LS, EN19WI30LS
and EP19WI30LS
- When supplying combustion air from the indoors, the room temperature must be greater than 32°F (0°C) to
prevent freezing and the room inside must not have negative pressure.
* The freeze prevention heaters will not prevent the plumbing external to the unit from freezing.
Protect this plumbing with insulation, heat tape or electric heaters, solenoids, or pipe covers.
If there remains a freezing risk, contact the nearest Electrolux agent.
Take the measures below for extremely cold temperatures*.
Outside temperature including wind chill factor less than -30°F (-35°C) for EN18WI30LS, EP18WI30LS
EN19WI30LS, EP19WI30LS
- When supplying combustion air from the indoors, the room temperature must be greater than 32°F (0°C) to prevent
freezing and the room inside must not have negative pressure.
This method can protect not only the heater, but also the water supply, water piping and mixing valves.
1. Turn off the power.
2. Close the gas supply valve.
3. Open a hot water fixture, and keep a small stream of hot water
running. (0.1 gallon (400cc)/minute or about 0.2" (4mm) thick.)
* If there is a mixing valve, set it to the highest level.
* When linking multiple units, discharge water equivalent to
(0.1 gallon (400cc)/minute per unit.)
4. The flow may become unstable from time to time.
Check the flow 30 minutes later.
* In general, it is not advisable to run water through the unit when
it is OFF ( p. 6), but in this case freeze prevention is more important.
* Remember to set mixing valves and fixtures to their original levels before using the unit again
to prevent scalding.
* If there is still a risk that the unit will freeze, drain the unit as shown on the next page.
If water will not flow because it is frozen
1. Close the gas and water valves.
2. Turn off the power button.
3. Open the water supply valve from time to time to check whether water is running.
4. When the water is flowing again, check for water leaks from the equipment and piping before using.
If the heater or the piping is frozen, do not use the heater or it may get damaged.
41