iNSlallaliON iNSIRUcliONS READ ALL iNSTRUCTiONS BEFORE iNSTALLATiON iNSTALLATiONSAFETY iNSTRUCTiONS BEFORE YOU BEGIN Note to Installer: Leave these instructions with Read these instructions completely the appliance after installation is completed. and carefully. Note to Consumer: Keep the User's Guide and Installation of this range must conform with local Installation...
iNslallaliON iNSIRUcliONS READ ALL iNSTRUCTiONS BEFORE iNSTALLATiON iNSTALLATiONSAFETY iNSTRUCTiONS (continued) BEFORE YoU BEGIN Remove all tape and packing materials before using the range. Dispose of all plastic bags after unpacking the range. Never allow children to play with packing materials. iMPORTANT SAFETY iNSTRUCTiONS Read these instructions completely...
Page 4
iNslallaliON iNSIRUcliONS READ ALL iNSTRUCTiONS BEFORE iNSTALLATiON iNSTALLATiONSAFETY iNSTRUCTiONS (continued) - If the range is pulled away from the wall for WARNING! cleaning, service, or any other reason, ensure that the Anti-Tip Device is properly reengaged when the range is pushed back against the wall. •...
iNslallaliON iNSIRUcliONS READ ALL iNSTRUCTiONS BEFORE iNSTALLATiON INSTALLATIONSAFETY iNSTRUCTiONS (continued) ,_ WARNING! If a 30" clearance between cooking surface and • The vertical distance from the plane of the cooking overhead combustible material or metal cabinets surface to the bottom of adjacent overhead cannot be maintained, protect the underside of the cabinets extending closer than 1"...
iNslallaliON iNSIRUcliONS DIMENSIONS AND cLEARANcES Provide proper clearances between the range and The range may be placed with 0" clearance (flush) at the back wall. adjacent combustible surfaces. These dimensions must be met for safe use of your range. The location of the electrical outlet and pipe opening (see "GAS PIPE AND ELECTRICAL OUTLET LOCATIONS") may be adjusted to meet specific requirements.
Page 7
iNSTAiiATiON i NSTRUcTiONS LOCATION Do not locate your range where it may be subject When the floor covering ends at the front of the to strong drafts. Any openings in the floor or wall range, the area that the range will be installed on behind the range should be sealed.
Page 8
iNSTAiiATiON i NSTRUcTiONS GAS PiPE AND ELECTRICALOUTLET LOCATIONS Recommended area for 120V outlet on rear wall and area for through-the wall connection pipe stub and shut-off valve. tRh::ug_thedfl od : rr:: nf: re ct io n f pipe stub and shut-off valve. SUPPLY 1.
Page 9
iNslallaliON iNSIRUcliONS 2. CONNECT THE RANGE TO (;AS Shut off the range gas supply valve before Connect a flexible metal appliance connector to removing the old range and leave it off until the the adapter on the range. Position range to permit new hook-up has been completed.
iNslallaliON iNSIRUcliONS 3. ELEcTRicAL cONNEcTiONS ELECTRICAL REOUIREMENTS 120 Volt, 60 Hertz, properly grounded dedicated circuit protected by a 15 or 20 Amp circuit breaker, or slow blow fuse. GROUNDING iMPORTANT: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. The power cord of this appliance is equipped with a CAUTION: 3-prong (grounding) plug which mates with a standard 3-prong grounding wall receptacle to minimize the...
iNslallaliON iNSIRUcliONS 5. ASSEMBLE THE SURFACE BURNERS CAUTION DO NOT operate the burners without all parts in Hole _: place. ,°c.ode Place the burner caps and heads on the cooktop. Make sure that the caps and heads are placed in the correct locations.
Page 12
iNslallaliON iNSIRUcliONS 7. ADJUST THE SURFACE BURNER TO THE LOW FLAME(SIMMER) SETTING. 1) Light all surface burners. 2) Turn the knob on the burner being adjusted to "LO". Remove knob. Insert a small, flat bladed screwdriver into the valve Center adjustment screw Adjustment...
Page 13
iNslallaliON iNSIRUcliONS 8. cHEcK OPERATION OF BAKE/BROIL BURNERS To check ignition of the Bake burner, follow the steps To check ignition of the Broil burner, follow the steps below: below: 1) Remove all packing from inside the oven cavity. 1) Press "Broil" ("Hi" will be shown in the display). 2) Press "Bake"...
iNslallaliON iNSIRUcliONS 10. iNSTALLiNGTHE ANTI-TIP DEVICE INSTALL THE BRACKET USING THE WARNING BRACKET INSTALLATION SHEET • Range must be secured with an approved Anti-tip Anti=Tip device. )late • The range could be tipped by standing, sitting or leaning on an open door if the range or Anti-Tip device is not properly installed.
iNslali_aliON i NSIRUcliONS WHEN ALL HOOKUPS ARE COMPLETE Make sure all controls are left in the off position. Make sure the flow of combustion and ventilation air to the range is unblocked. CONVERTING TO LP GAS (OR CONVERTING BACK TO NATURAL GAS FROM LP) The conversion instructions and LP orifices can be This range leaves the factory set for use with natural gas.