Appendix A Event Notification Message List
A.2 Message List
A.2.5
Test Messages
The messages that are sent when the test notification of an event is performed in ETERNUS Web GUI or
ETERNUS CLI are described below.
■
Test mail transmission
The message is notified when the test notification of e-mail is performed in ETERNUS Web GUI or ETERNUS CLI.
Event type code
T FFFFFFFF
■
Test Trap transmission
The message is notified when the test notification of the SNMP Trap is performed in ETERNUS Web GUI or
ETERNUS CLI.
Trap No.
2
0x80000000
The Trap No. and ItemId in the test Trap are the same as the notification that is sent when a drive in Slot#0 in
CE is in Fault status. A drive is not actually disconnected when a test Trap is notified.
A.2.6
Sense Codes
This section describes the sense codes that are notified to the server.
Sense code
SK
ASC
02
04
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
Test e-mail Message
TrapItemId
SNMP Trap Test
ASCQ
00
The device is in Not Ready status.
Copyright 2013 FUJITSU LIMITED
Message
TrapMessage
Description
149
Remarks
This sense code is notified when "Not
ready" is enabled for Error Severity Level
in the event notification setting.
This is not notified during maintenance
operations.
P3AM-4842-12ENZ0