8.1.2 Combined Units
Delegate microphones with transmission links to
delegate headphones and auxiliary outputs.
General
Frequency response:
Total harmonic distortion at overload
at nominal input
level (85 dB SPL):
at max. input
level (110 dB SPL):

8.2 Mechanical Data

8.2.1 Control and Power Supply Unit
Mounting:
Dimensions(HxWxD): 84 x 361 x 143 mm (with 5.5
Weight:
8.2.2Delegate/Chairman Units
Dimensions (w x d x h)
without mic.:
Length of mic. from
mounting surface:
Weight:
Bosch Security Systems | 2003-06 | 3922 988 54284
125 Hz - 12.5 kHz tolerances
acc. to IEC 914 standard
< 0.5%
< 3%
free standing on a table top or
mounted in a 19" rack (requires
3HU (Height Units) with bracket
set LBB 3311/00). Information
about how to make the necessary
brackets for table flush mounting
is included.
mm feet)
3.4 x 14.2 x 5.6 in (with 0.22 in
feet).
/00 version 1.5 kg (3.3 lb)
/10 version 1.7 kg (3.7 lb)
124 x 172 x 63 mm
(4.9 x 6.8 x 2.5 in)
/00 version, 313 mm (12.3 in)
/50 version, 488 mm (19.2 in)
0.9 kg (2.0 lb)

8.3 General Data

8.3.1 System Environmental Conditions
Temperature range
Storage and transport: -20 to +70°C (-4 to +158°F)
Operational:
+5 to +45°C (+41 to 113°F)
Ambient humidity
Operational:
20% - 95% RH
Storage and transport: 0% - 99% RH
Air pressure:
600 mBar - 1100 mBar
Safety:
acc. to EN 60065 and acc. to
UL6500
Resistance to shock,
vibration, bump
and transport:
acc. to IEC68, 5G acceleration
EMC emission:
acc. to EN 55103-1 and FCC
rules (part 15), class A
EMC immunity:
acc. to EN 55103-2
EMC approvals:
affixed with the CE mark EC
directive 89/336 EEC
ESD:
acc. to IEC 801-2 and 801-4
Mains harmonics:
EN 61000-3-2 and EN61000-3-3
Transport:
UN-D 1400