Hardware setup Camera connections Audio connections Monitor connections 4.3.1 VGA (Monitor A and Monitor B) Keyboard connections Ethernet connection RS485 port USB connectors External alarm I/O connection Power supply Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Page 4
Continuous Recording 6.1.5 Input Recording 6.1.6 Motion Recording 6.1.7 Network Live Streaming 6.1.8 Video format Schedule 6.2.1 Schedule Display 6.3.1 Language 6.3.2 Monitor A 6.3.3 Monitor B Event F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Page 5
8.2.1 Open button Camera Views Viewing Images 8.4.1 Assigning Cameos Using the playback controls 8.5.1 Capturing a still image Find image Video slider bar Checking authenticity Exit button Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Page 6
Electromagnetic and Safety 10.2 DVD compatibility 10.3 USB memory sticks Appendix Software licenses A.1.1 Bosch software A.1.2 Other licenses — copyright notices A.1.3 Warranties and disclaimer of warranties F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Controls adjustment - Adjust only those controls specified in the operating instructions. Improper adjustment of other controls may cause damage to the unit. Use of controls or Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Page 8
17. Attachments, changes or modifications - Only use attachments/accessories specified by the manufacturer. Any change or modification of the equipment, not expressly approved by Bosch, could void the warranty or, in the case of an authorization agreement, authority to operate the equipment.
Disposal - Your Bosch product was developed and manufactured with high-quality material and components that can be recycled and reused. This symbol means that electronic and electrical appliances, which have reached the end of their working life, must be collected and disposed of separately from household waste material.
Page 10
SELV - All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits should only be connected to other SELV circuits. Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING- RELATED FUNCTIONS OF THIS PRODUCT. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
| Safety Video Recorder 630/650 Series Bosch notices Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
2.1.1 Versions There are various DVR 630/650 Series models; the most extensive model has 16 channels and a built-in DVD writer. The DVR 630 does not have a DVD writer; the DVR 650 does. 2.1.2...
If any items are missing, notify your customer service representative or Bosch Security Systems sales representative. The shipping carton is the safest container in which to transport the unit. Save it and all packing materials for future use.
Warranty Failure to follow the Safety Instructions, Installation Instructions, and any other instructions noted in this manual may result in damage to the unit and void the warranty. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Connect a pan/tilt/zoom control unit to the RS-485 port (via the supplied screw terminal block). Connect to your network via the Ethernet port. Connect a Bosch Intuikey keyboard cable to the Keyboard-IN port if required. 3.1.3 Powering up Switch on all connected equipment.
To restore the unit to its factory default: Remove power from the DVR. Press and hold the OSD key on the front panel. Supply power to the unit. – The factory defaults are restored. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Fill in the current time. Date format Select from three date formats which show either the month (MM), the day (DD), or the year (YYYY) first. Date Fill in the current date. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Quick install | en 3.3.2 Continuous Recording Figure 3.4 Quick install - Continuous Recording Set the Continuous Recording Resolution, Quality, Frame rate, Covert, and Audio for each profile in the table. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
The actual values are displayed. IP address, Subnet Fill in the IP, subnet mask, gateway addresses, and DNS server mask, and Gateway addresses when DHCP is not enabled. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Gain control: Automatic gain control for each video input Connector type: BNC looped-through, automatic termination Figure 4.1 16 video inputs with loop-through outputs Figure 4.2 8 video inputs with loop-through outputs Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Hardware setup | en Keyboard connections The keyboard input and output connectors are used to connect a Bosch Intuikey keyboard to one or more DVR 600 Series units. For one unit, connect the keyboard to the Keyboard in connector. For more units, connect a cable between the Keyboard out connector of the first unit and the Keyboard in connector of the following DVR 600 Series unit.
Supports 3.3V or 2.5V signaling for RGMII – Supports power down mode and supports Link Down Power Saving – 64-pin QFN or 100-pin LQFP – Connector: RJ45 Figure 4.6 RJ-45 Ethernet connector F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Video Recorder 630/650 Series Hardware setup | en RS485 port Connect Bosch, Pelco-P or Pelco-D controllable cameras to the unit for pan, tilt, and zoom control. The Bosch protocol is supported with the following baud settings: – 9600 baud –...
USB memory device. (Recording to a USB-drive is not supported.) Figure 4.8 USB connector (on front and on rear) Note: USB memory sticks must have FAT32 formatting. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Electrical voltage. Risk of electric shock. Do not open the top cover or attempt to service the unit. No user serviceable parts inside. Refer all servicing to qualified service personnel. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
System Menus Covert Table 5.1 User Levels and permissions Front panel controls Figure 5.1 Front panel controls Note: 8-channel models have only 8 camera keys on the front. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
– in quad mode, press to toggle to full screen Sequence key – view cameras in sequence on full-screen or quad displays F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Power - lights green when the unit is powered Network - lights green to indicate network activity Alarm - flashes red when an alarm is detected Record - lights red when the unit is recording video Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
The buttons and indicators of the System Control Bar work the same as the keys and indicators on the front panel. – The System Control Bar can also be controlled with the Arrow Keys and Enter Key. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Press the ID button on the remote control. Press a number between 1 and 9 that corresponds to the unit ID you wish to control. Figure 5.3 Remote control Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
From the pop-up menu, select the display for Monitor B – Select the quad key to select the quad mode – Select the sequence key to sequence the quad mode F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Table 5.2 Multi-screen viewing in 4:3 and 5:4 Resolution (aspect ratio) 1366x768 (16:9), 1440x900 (16:10) Full screen Quad 1+2+6 4x4 (Not for 8-channel model) Table 5.3 Multi-screen viewing in 16:9 and 16:10 Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Page 36
Alternatively, right click a cameo with the mouse and choose a video input from the Cameo Menu. This cameo assignment is used in playback mode as well as in live mode. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Page 37
Alternatively, right click and select Zoom or Exit zoom to enable or disable zoom mode with the mouse. While in zoom mode, move the mouse pointer to select the area of the picture to be displayed. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
– Press the play key to resume playback. Press the stop key to switch back to live viewing. An alarm also switches the unit back to live viewing. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
To open the menu, move the pointer to the bottom of the screen. – The System Control Bar appears on monitor A. To open the menu, click the menu icon. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
NTP - set NTP Time Server and Sync interval – Beeper - set unit to beep on Button, Input, Motion, System, or Video loss – User - set Usernames, Passwords, and User Levels for Users 1-10 F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Move the cursor to the bottom of the screen to access the System Control Bar. Click the search icon. – The default search is a Date/time search. Figure 5.5 Default menu - Search Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
With a mouse, click directly on the timeline to set the start time. Click Play to start playback: – Playback in all displayed cameos will start. Figure 5.6 Search menu - Date/Time Search options F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
The event search results are indicated by a start and stop time of a small period of video. Within this period of video the event search results can be found. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
The smart search results are indicated by a start and stop time of a small period of video. Within this period of video the smart search results can be found. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
If the total size of the video segments is greater than the memory device’s free space, then only the first segments that fit are archived. Click File to save ‘Export history log file’ to USB. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
– MAC Address – IP Address – Software Version Figure 5.10 System Control Bar - System information Click Video info to see more information about the video connections. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Page 47
The video information menu shows the video system that has been set and the inputs on which video signals have been detected. Click Hard disk to see more information about the hard disks. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Page 48
The Disk info menu provides information on the size and usage data of the hard drives. Note: Only Bosch hard disks with a signature can be used. If the hard disk is not certified, it cannot be used for recording.
– Log contents are ordered from latest to earliest. Export log click Export to save the log file to a USB device. Figure 5.13 Logbook - Logbook filter Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Monitor B: Full screen or sequenced display of pre-programmed cameras. – The alarm beeper sounds. The alarm indicators flash. – A controllable camera might be moved to a pre-defined position. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Monitor A can switch to a multiscreen view if more than one alarm occurs. The latest alarm status message is always shown. Press the acknowledge key to deactivate all alarms. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
The configuration menu has six major menu groups listed across the top. Each of these groups has a set of drop-down submenus which provide access to a screen where the values and functions can be selected and changed. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Page 53
Monitor A Monitor B Event Input Motion Alarm Acknowledge System Network TCP/IP DDNS Notification Mail System Date/Time Beeper User Configuration Hard Disk System Table 6.1 System Configuration menu structure Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Administrator level users are able to view live, playback, and archive covert video. Audio Enable Audio input when an audio source is connected for the specified channel. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Table 6.2 Maximum Frame Rates (PAL/NTSC IPS) by Resolutions for enabled Channels 6.1.2 Video adjustment Figure 6.3 Camera - Video adjustment Channel Select the camera channel for adjustment. The preview will display the channel indicated. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Select a COM port, Control ID, and Protocol for PTZ when a controllable camera is connected. – Pan and Tilt can be tested within the menu. – By default, PTZ is disabled (Com port is set to None) for all inputs. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Frame rate - set the video frame rate to 25/30, 12.5/15, 6.25/7.5, 5/6, 2.5/3, or 1/1 IPS (Images Per Second in PAL/NTSC). Note: For 16-channel units, use the ch09 to ch16 or ch01 to ch08 button to display the required cameras. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
The pre-event recording time is dependent on video complexity, resolution, quality, and frame rate settings. Post-event Post-event recording duration can be set between 10 seconds and 10 minutes, or set to Follow the alarm state. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Figure 6.8 Camera - Network Live Streaming Use the same procedure as Continuous Recording to set the values for cameras that will be streamed over the network. – Network streams are not recorded. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
DVR to either PAL or NTSC. Select the Monitor format to match the best VGA resolution on the used VGA monitor (monitor A). F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Use Day copy to copy the settings of the schedule to another day. – Use Ch copy to copy the settings of the schedule to another channel. When finished, select Exit to save the updated schedule. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
The Sequence dwell time is used during Sequence or if multiple active events trigger the monitor. 6.3.3 Monitor B Use the same procedure as Monitor A (playback items are not available). F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
For the camera associated with the input, a PTZ preset can be sent to the camera to move to a specified pre-position. – Enter a pre-position number from 1-255 for each of the PTZ cameras that should be moved. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Use the arrow keys to move around the grid, pressing the enter key to toggle each grid block from active to inactive. – Click Set All to set the selected area to its default value. Click Clear All to delete the selected area. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Select the Post-event time to enable the unit to automatically acknowledge alarms when the post-event time is expired. Select Manual to require the operator to press the Acknowledge key to acknowledge an alarm. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Figure 6.15 Event - System menu For each system event, select relay number 1, 2, 3 or 4 to activate an output relay when an events occurs, or select None for no activation. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Connecting using a smart mobile phone Your smart phone should support RTSP network protocol and includes a RTSP capable player application that can display H.264 video streams. The RTSP transports the remote (network) Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Page 68
If the RTSP port is not the default port (554), use the following on the smart phone. – rtsp://xxx.xxx.xxx.xxx:firewall open port/cgi-bin/rtspStream/1 Note: xxx.xxx.xxx.xxx is the DVR IP address; 1 refers to channel 1, 2 refers to channel 2, etc. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
The providers supported are: dyndns.org, tzo.com, and sitessolutions.com. 6.5.5 Notification Figure 6.18 Network - Notification Select the events that will trigger the unit to send an e-mail. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
If not required, do not enable this feature. User name and Password If authentication is required, regardless of encryption, enter the User name and Password provided by your administrator in each field respectively. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Press NTP Test to start time synchronization. Set the Synchronization Interval to keep the unit closly matched with the time source. – Intervals can be as frequent as hourly, or as long as monthly. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Enter a Password up to 12 characters. Control access to the system by selecting a user Level. – User Level can be set to Administrator, Advanced or Normal user. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Once started, the unit must not be powered off until the update is completed. – Quick install opens the Quick install menu that was first presented when the unit was powered on when received from the factory. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Auto delete sets a time window outside of which all video will be deleted from the unit. This function is primarily reserved to meet legal requirement in some jurisdictions. – Format erases all data from the selected partition. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
– Auto user logout sets the period of inactivity after which the user will be automatically logged out from the unit. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
– Once installed on a PC, the Web Client will not need to install the OCX again unless a new version is released with a new unit firmware. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
The Web Client allows access to and use of unit menu items. These menu items are explained in Section 6 Configuration menu, page 52. Although the structure is the same, menus and settings behave differently because of the Web Browser. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
On this screen, the user can: – view live video – select different multiscreen displays – assign cameras to cameos – control ptz cameras – monitor unit status and alarm conditions F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
– view a graphical timeline of the day for recording, input, or motion events. Figure 7.3 Web Client - Playback Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
On this screen, the user can: – export a file remotely to the PC; – choose the channel, audio, start and end date/times to export. Figure 7.4 Web Client - Export F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Configuration mode Click the Configuration button to enter the Configuration menu. This allows set up of all the configuration settings for the unit. Figure 7.5 Web Client - Configuration Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
– If the file is not listed, scroll down the list or choose the right location. Click Open. To exit the program, click Cancel or the close button. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
When zoom is selected, left click on the cameo to zoom out, right click to zoom in. Click, hold, and drag inside the cameo to move the image around. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
The step function is only enabled in the still mode. Click Step backward to move the image back one frame. Hold it down to continue stepping at a maximum rate of 3 images per second. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
This opens the Authenticity information window. This window shows details of the video frame shown in the cameo when it was clicked. Exit button Click the Exit button to stop using the Archive Player. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Cameras 1-8/16 Resolution Recording Video quality Normal Frame rate 30 (NTSC)/25 (PAL) Covert Audio None Network Setup DVR ID DHCP Enabled IP address 0.0.0.0 Subnet mask 0.0.0.0 Gateway 0.0.0.0 F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Page 87
Video format Auto-Detect on Camera 1 Monitor format 800x600 (4:3) Schedule Sunday Continous Monday Continous Tuesday Continous Wednesday Continous Thursday Continous Friday Continous Saturday Continous Exception Days None Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Page 88
All On Alarm acknowledge Post-Event Time System Disk Fail None Disk Full None Fan Fail None System/Disk Temp None Admin Password None Changed Video Loss None Power On None F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Page 89
Send Mail SMTP Server EMPTY SMTP Port User Name EMPTY Password EMPTY More Mail Settings From EMPTY Subject EMPTY To (1) EMPTY To (2) EMPTY To (3) EMPTY Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Page 90
Start Start of Video Current Time Sensitivity Area Table 9.4 Archive menu default values Navigation Setting Default value Reset Archive Channel None Start Time None End Time None F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Control RS485 Output signals according to RS485 max. signal voltage -8 V to +12 V RS485 support Bosch domes and Pelco-P and D Keyboard Intuikey; 12 VDC, 400 mA max. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
355 x 362 x 78 mm (W x D x H) 13.9 x 14.2 x 3.1 inch (W x D x H) Weight (excluding hard disk) approx. 4.3 kg / 9.46 lbs F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
Operating: 0 °C to +40 °C (+32 °F to +104 °F) Storage: -40 °C to +70 °C (-40° F to +158 °F) Relative humidity Operating: <93% non-condensing Storage: <95% non-condensing Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
Kingston DataTraveler II plus MIGO 8 GB Table 10.2 Recommended USB memory sticks Note: USB memory sticks must be formatted according to the FAT32 standard. No other standard is allowed. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
– CDDL v1.0 — http://www.openssl.org/source/license.html Bosch is committed to comply with the relevant terms of any open source license included in its products. To this effect, Bosch has created a web site (www.boschsecurity.com/oss) to enable any licensee of open source software to have access to the relevant source code or other information that such licensee may be entitled to under the terms of a relevant license.