RAID Subsystem DVA-16K | Installation Manual
4.3
Audible Alarm
Different controller environmental and operational parameters (like temperature, etc.) have
been assigned a range of values between which they can fluctuate. If either the upper or lower
thresholds are exceeded, an audible alarm will automatically be triggered. The alarm will also
be triggered when an active component on the RAID subsystem fails. If the RAID subsystem
manager is onsite and hears an alarm, the manager must read the error message on the LCD
screen or PC terminal to determine what has triggered the alarm. After determining what has
occurred, the RAID subsystem manager must take appropriate actions to rectify the problem.
CAUTION!
If an alarm is triggered it is necessary for you to determine the problem. If the audible alarm is
ignored and the problem is not rectified, unexpected damages may occur.
4.3.1
Default Threshold Values
Table 4.7 shows the default threshold values for the RAID subsystem. If any of these values are
surpassed, the alarm will sound:
+3.3V
+5V
+12V
CPU Temperature
Board
Temperature
Enclosure
Ambient
Temperature
Table 4.7 Default Threshold Values
The thresholds in Table 4.7 are default threshold values and may be changed.
4.3.2
Failed Devices
If any of the following devices fail, the audible alarm will be triggered:
•
•
•
•
•
NOTICE!
i
When the temperature exceeds a preset threshold, the controller's charger circuits will stop
charging. You will then receive a message that says "Thermal Shutdown/Enter Sleep Mode."
When the temperature falls back within normal range, the battery will resume charging.
Bosch Security System
Upper Threshold
+3.6V
+5.5V
+13.2V
90ºC
80ºC
40ºC
RAID controller module
Cooling modules
PSU modules
BBU
Hard drives
Subsystem Monitoring | en
Lower Threshold
+2.9V
+4.5V
+10.8V
5ºC
5ºC
0ºC
F.01U.027.799 | V2 | 2008.08
31