Page 1
INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE Please read these instructions thoroughly before installing and operating the range. LDE3019ST LDE3015ST LDE3017ST LDE3015SB LDE3017SB LDE3015SW LDE3017SW www.lg.com P/No.: MFL63290401...
Part 1 SAFETY BEFORE YOU BEGIN Remove all tape and packing materials before using the range. Dispose of all plastic bags after unpacking the range. Never allow children to play with packing materials. IMPORTANT SAFETY INSTRUCTIONS Read and follow all instructions before using your oven to prevent the risk of fire, electric shock, personal injury, Safety Glasses or damage when using the range.
Page 3
Part 1 SAFETY WARNING • The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block.
Part 1 SAFETY Safety Glasses Tape Measure PREPARE TO INSTALL THE RANGE WARNING Gloves Pencil TOOLS NEEDED Safety Glasses • The information in this manual should be followed exactly. Tape Measure Safety Glasses - A fire or electrical shock may result causing property damage, personal injury or death.
Page 5
Part 2 PREPARE TO INSTALL THE RANGE Tape INSTALLATION DRAWINGS (LDE Series only) WARNING NOTE • You should use two or more people to move SAVE FOR THE USE OF THE LOCAL and install range. (Excessive Weight Hazard) ELECTRICAL INSPECTOR. - Failure to do so can result in back or other injury.
Part 3 ELECTRICAL CONNECTIONS ELECTRICAL CONNECTION CONNECT RANGE CORD Tape REQUIREMENTS WARNING This appliance must be installed and grounded on a branch circuit by a qualified technician in accordance with the • You never remove the protection cover National Electrical code ANSI/NFPA NO. 70 - latest edition. covering the rear of lower oven.
Page 7
Part 3 ELECTRICAL CONNECTIONS Safety Glasses 3-wire connection with a power supply cord Tape Measure WARNING Gloves Pencil • The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block.
Page 8
Part 3 ELECTRICAL CONNECTIONS Safety Glasses 4-wire connection with a power supply cord 3-wire connection: conduit Tape Measure Install the conduit as follows: WARNING Pencil Gloves Remove the Conduit connection plate from the rear of • Only a 4-conductor power-supply cord kit lower oven and rotate it as shown in Figure 5.
Page 9
Part 3 ELECTRICAL CONNECTIONS 4-wire connection: conduit 1. Follow the instructions under “Install the conduit as 4-wire connection follows” on page 7 to correctly install the strain relief. DO NOT install the conduit without a strain relief. 2. Loosen the 2 lower left and right screws from the terminal block.
Part 4 INSTALL THE RANGE Replace the access cover on the back of the range. To replace the wire cover, insert the two tabs into the openings located below the opening and tighten the three screws. Safety Glasses Tape Measure Use a level to check your adjustments.
Page 11