Download Print this page

Miele DA 259-4 Operating And Installation Instruction page 8

Cooker
Hide thumbs Also See for DA 259-4:

Advertisement

One of the following technical
measures may be necessary to ensure
safe operation.
– If the only way of ensuring adequate
ventilation is via an open window, a
window contact switch should be
fitted to ensure that the cooker hood
can only operate when the window is
opened sufficiently. A window
contact switch kit is available from
good builders' merchants.
Take care when ventilating the room
through an open window that
ventilation is not impaired by a
closed blind or curtain.
– The cooker hood can be set up to
automatically switch on an air intake
fan or open a motorised inlet flap
when it is switched on.
– The cooker hood can be set up to
automatically switch off a heating
appliance which also depends on
the air from the room when it is
switched on.
The Miele DSM 400 control module
offers the possibility of combining other
components with the cooker hood (see
"Operation with Control module
DSM 400").
It is available to purchase as an
optional extra.
If in any doubt, the advice of a
competent builder or, for gas, a
"Corgi" installer, must be sought.
If the hood is being operated in
recirculation mode, the above
restrictions do not apply.
8
The manufacturer cannot be held
liable for damage caused by
non-compliance with these Warning
and Safety instructions.

Advertisement

loading

This manual is also suitable for:

Da 259-4 extDa 259-4 uDa 252-4 ext