Mode; Caching Page; Error Recovery Parameters Page; Power Condition Page - Pioneer BDR-203 Command Reference Manual

Hide thumbs Also See for BDR-203:
Table of Contents

Advertisement

BDR-203/BDC-203 Command Reference Manual
4.12.2 Mode Pages
The drive is not supported the Parameters Savable (PS) bit and must be set to zero.
The Page Code field identifies the format and parameters defined for that mode page.
The drive supports following Mode pages.
Table 31 - Mode Page Codes
Page code
01h
Error Recovery Page
05h
Write Parameters Page
08h

Caching Page

0Eh
CD Audio Control Page
1Ah

Power Condition Page

1Dh
Time-out & Protect Page
2Ah
Capabilities & Mechanical Status Page
3Fh
Return all pages (valid only for the MODE SENSE command)
4.12.2.1 Caching Page
The Caching Page is supported for compatibility of other CD-R/RW drive. This page has no effect on write/read operation. The
returned Caching parameters by the MODE SENSE (10) Command are modified to the new parameters after receiving new
parameters by MODE SENSE (10) Command.
Table 32 - Caching Parameter
7
Bit
Byte
0
PS
1
2
IC
3
4
(MSB)
5
6
(MSB)
7
8
(MSB)
9
10
(MSB)
11
Default value of the WCE bit is one. Default value of any other bits and field is zero.

4.12.2.2 Error Recovery Parameters Page

The AWRE and ARRE bits are not supported and are ignored.
The TB, RC, DTE and DCR bits are ignored.
The PER bit and EMCDR field are used to control the defect reporting.
Setting value of the Read Retry Count and the Write Retry Count field are ignored.
4.12.2.3 Power Condition Page
The default value of an Idle bit is one. The default value of the Idle Timer field is 000000c8h (20 second).
The default value of the Standby bit is one. The default value of Standby Timer field is 000012C0h (8 minutes).
4.12.2.4 Time-out & Protect Page
The DISP, SWPP bits are not supported and must be set to 0.
Description
6
5
Reserved
ABPF
CAP
Demand Read Priority
Disable Pre-fetch Transfer Length
Maximum Pre-fetch Ceiling
Page 32
4.12.2.2 on page 31
4.12.2.5 on page 32
4.12.2.1 on page 31
See SFFC INF-8090i document
4.12.2.3 on page 31
4.12.2.4 on page 31
4.12.2.6 on page 33
4
3
Page Code = 08h
Page Length = 0Ah
DISC
SIZE
WCE
Write Retention Priority
Minimum Pre-fetch
Maximum Pre-fetch
Version 0.90
Section
2
1
MF
RCD
(LSB)
(LSB)
(LSB)
(LSB)
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bdc-203

Table of Contents