Electric and gas commercial stacked dryer

Advertisement

8E, q8
OWNER'S MANUAL
and
INSTALLATION
INSTRUCTIONS
for Electric and Gas
Commercial
Stacked Dryer
SEARS,ROEBUCK AND CO.
HoffmanEstates,IL 60179
www.sears.com
TABLE OF CONTENTS
Dryer Safety ............................................................
2
Installation Instructions .........................................
3
Electrical requirements ........................................
4
Gas requirements ..............................................
10
Exhaust requirements ........................................
12
Recessed area/closet installation ...................... 14
Other Installation ................................................
15
the dryer ..............................................
18
....................................................
19
Service and Assistance ....................................... 24
For Sears warranty information
or to contact a Sears Service
Center, call 1-800-4-MY HOME _;M (1-800-469-4663).
IMPORTANT:
Read and follow all safety, installation, and
operating instructions before first use of this product.
If you need
SERVICE
or PARTS
for your
Kenmore
coin-operated
dryer:
When requesting service, be ready to give the model
number, serial number (located on a tag in the door well
behind the door) and date of purchase. Record below.
Model No
Serial No.
Date of Purchase
Record
Coin Box
Key Number
Key number is on key and/or coin box.
8530030
PRINTED IN THE U S A
8/01

Advertisement

loading

Summary of Contents for Kenmore 11062182100

  • Page 1: Table Of Contents

    Stacked Dryer If you need SERVICE or PARTS for your Kenmore coin-operated dryer: When requesting service, be ready to give the model number, serial number (located on a tag in the door well behind the door) and date of purchase. Record below.
  • Page 2 Before you start... Your safety and the safety of others are very important. We have provided many important safety messages Explosion Hazard in this manual and on your appliance. Always read Keep flammable materials and vapors, such as and obey all safety messages. gasoline, away from dryer.
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions, including the following: • Read all instructions before using the dryer. • Do not use fabric softeners or products eliminate static unless recommended...
  • Page 4 If using a power supply cord: Dryer power supply cord must be: • U.h-listed or CSA certified • 120!240 volt minimum • 30 amp Athree-wire orfour-wire, singlephase 120!240-volt, • Type SRD or SRDT 60-Hz., AC-only, electrical supply is required ona •...
  • Page 5 1. Disconnect power. Four-Wire Power Supply Cord Connection 2. Remove hold-down screw and terminal block cover. 3. Attach a ¾-inch U.h-listed, strain relief to the hole below terminal block opening. Strain relief should have a tight fit with dryer cabinet and be in a horizontal position.
  • Page 6 Four-Wire Direct Wire Connection 1. Disconnect power. * Strip 5 inches of outer covering from end of cable. Leave bare grounding wire at 5 inches. * Cut 1 inch from 3 remaining insulated wires. Strip insulation back 1 inch. Shape the end of each wire Fire Hazard into a "U"...
  • Page 7 5.Connect neutral g rounding w ireandtheneutral w ire Grounding Instructions (white orcenter) o fdirect w irecableunder thecenter screwofterminal b lock. • For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the Center silver-colored risk of electric shock or breakdown;...
  • Page 8 1.Disconnect power. Three-Wire Direct Wire Connection 2. Remove h old-down s crewandterminal b lock cover. Terminal block cover Hold-downscrew Fire Hazard Use 10 gauge solid copper wire. Use a UL approved strain relief. 3. Attach a K-inch, U.L.-listed, strain relief to the hole Disconnect power before making electrical below terminal block opening.
  • Page 9 2.Remove h old-down s crewandterminal b lock cover. Alternate Connection: Terminal block cover If local codes do not permit the connection of a frame- Hold-downscrew grounding conductor to the neutral wire: 1. Disconnect power. 2. Make sure the power supply cord or direct wire cable is in place.
  • Page 10 • This dryer is equipped for use with NATURAL GAS. It is certified by CSA International for LR (propane and butane) gases with appropriate conversion. No attempt shall be made to convert the appliance from the gas specified on the serial/rating plate for use with a different gas without consulting the serving gas supplier.
  • Page 11 • Foreaseof installation, operation, andservicing adequate space shouldbeprovided around thedryer. • A 1/8-inch NPTplugged tapping, a ccessible f ortest gaugeconnection, mustbe installed immediately upstream of thegassupply connection t o thedryer. Thedryermustbedisconnected fromthegassupply piping system duringanypressure testing ofthe system attestpressures i nexcess of 1!2psig. Thedryermustbeisolated fromthegassupplypiping system by closing the equipment shut-off v alveduring anypressure t estingofthegassupply pipingsystem at...
  • Page 12: Installation Instructions

    WARNING - Improper c onnection o ftheequipment- • Disconnect vent from the dryer and clean one section grounding conductor canresult i n a riskof electric shock. at a time until you reach the exhaust hood. Check witha qualified electrician o r serviceman i f you •...
  • Page 13 permanent installation, a stationary e xhaust system is An exhaust hood should cap the outside end of the required. main vent to prevent exhausted air from returning to the dryers. If an exhaust hood cannot be used, the outside Exhausting t hedryerthrough the sideor bottom ofthe end of the main vent should have a sweep elbow dryerrequires the useof Exhaust K itPartNo.279818 directed downward.
  • Page 14: Exhaust Requirements

    1. Exhaust individual dryers to the central exhaust vent Determining vent length system with proper sized venting to assure adequate The maximum length of the exhaust system depends performance of each dryer. (Dryer has 4-inch exhaust upon: vent connection.) • The type of vent (heavy or flexible metal). 2.
  • Page 15: Recessed Area/Closet Installation

    Recessed area and closet installation %W _'>, ._*" I I Q_ I_>, I['_I I IC_I=I IJ I I requirements Installing coin-slide mechanism Recessed 1. Your dryers are set for 60 minutes of drying. If you wish, you may change to 30 to 45 minutes drying with the cams provided.
  • Page 16 Coin box adjustment Replacing nylon timing cams on accumulator mechanism The tight fit of the money box is set at the factory. Customer may loosen fit as desired by loosening the slotted nuts. Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating.
  • Page 17 7. Reassemble buffer. Changing Vend Price 8. Pull slide back to original position and reassemble Follow all instructions carefully. slide return spring. NOTE: Place all screws and other items removed from coin NOTES: slide assembly on a cloth so they will not get lost. * Black slots are closed off by block-out key.
  • Page 18: Operating The Dryer

    No washer can completely remove oil. Do not dry anything that has ever had any type of Every Kenmore automatic dryer is thoroughly lubricated oil on it (including cooking oils). at the time of assembly with lubricants designed to last the normal life of the product.
  • Page 19: Troubleshooting

    TROUBLESHOOTING •Heat element Check for broken element wire. • Gas burner Check for function. Before servicing the dryer, always check out the machine • Load to substantiate the complaint for which the service call was created. In many cases, it may just be a Check for size and type of load.
  • Page 20 Troubleshooting (cont.) If you need an additional parts list, contact your nearest Sears Service Center or Parts Drying temperature too high Department. Make sure to order by complete Model Number when ordering. • Operating thermostat Check for lint that may insulate thermostat from exhaust air.
  • Page 24 For major brand repair service: Call 24 hours a day, 7 days a week 1-800-4-MY-HOM ESM ( 1-800-469-4663) www.sears.com Para pedir servicio de reparacibn a domicilio - 1-800-676-5811 For the repair or replacement parts you need: Call 6 a.m. - 11 p.m. CST, 7 days a week PartsDirect 1-800-366-PART (1-800-366-7278) www.sears.com/partsdirect...