Electrolux EI30DD10KS Installation Instructions Manual

Installation instructions and owner’s guide telescoping downdraft ventilation systems

Advertisement

Quick Links

Installation Instructions and Owner's Guide
Telescoping Downdraft Ventilation Systems
P/N 316902914 (June 2012)

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux EI30DD10KS

  • Page 1 Installation Instructions and Owner’s Guide Telescoping Downdraft Ventilation Systems P/N 316902914 (June 2012)
  • Page 2: Table Of Contents

    Table of contents Please read & save this guide Finding Information ..........2 Thank you for choosing Electrolux, the new premium brand in home appliances. This Use & Care Guide is Important Safety Instructions ........3 part of our commitment to customer satisfaction and Product Dimensions ..........5...
  • Page 3: Important Safety Instructions

    Important Safety Instructions What you need to know about safety instructions Warning and Important Instructions appearing in this guide are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when installing, maintaining or operating an appliance.
  • Page 4: Grounding Instructions

    Important Safety Instructions TO REDUCE THE RISK OF A RANGE TOP • For general ventilating use only. Do not use to GREASE FIRE: exhaust hazardous or explosive materials and • Never leave surface units unattended at high vapors. settings. Boilovers cause smoking and greasy • To avoid motor bearing damage and noisy and/ spillovers that may ignite.
  • Page 5: Shipping Pack

    Shipping Pack Stabilizing Brackets Instruction Manual Cutout Template Warranty Card Telescoping Downdraft Tools You Will Need IMPORTANT • Phillips Screwdriver Retain all packing and materials until the telescoping downdraft and all components • 1/4” Nut Driver / Ratchet have been installed. •...
  • Page 6: Product Dimensions

    Product Dimensions Top Trim RISE 1-7/16” (3.7 cm) 2-1/4” (5.7 cm) 5-9/16” (14.1 cm) Control Model Rise EI30DD10KS 30” (76.2 cm) ” (68.3 cm) ” ” ” 10” (45.2 cm) (91.0 cm) (5.5 cm) (25.4 cm) EI36DD10KS 36” (91.4 cm) ”...
  • Page 7: Planning

    Planning Basic Information Take Measurements A qualified technician must complete the installation Refer to the cooktop installation instructions for of this appliance. This downdraft blower system is dimensions of the cooktop, countertop cut-out designed to be used to exhaust airborne contaminants and cabinet requirements.
  • Page 8 Planning Plan the Ductwork This downdraft blower system is designed for use with 3¼ x 14” ductwork (can be transitioned to 8” or 10” round). For best performance, choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions.
  • Page 9 Planning Plan the Electrical Connection NOTE The downdraft blower system draws 4 AMPS and If the 30” model is being installed in a 30” wide requires a 120 VAC, 60 Hz circuit. cabinet or the 36” model in a 36” wide cabinet, The unit has a 28 inch long power cord with a 3 the outlet cannot be located on the back wall of pronged grounded plug.
  • Page 10: Installation

    Installation Cut Countertop Opening Mount the Unit Set downdraft into opening and position with the - Lay out and cut the cooktop cut-out far enough back of the unit contacting the back edge of the forward so downdraft will fit behind it (refer to cooktop cutout.
  • Page 11 Installation Remove the Duct Transition Remove the Duct Transition from the Chassis Housing by removing the two Phillips screws as shown and sliding the Duct Transition out of the tabs. Tabs Duct Transition Phillips Head Screw Phillips Head Screw...
  • Page 12 Installation Remove Control Box Cover Make Blower Electrical Connection and Install Remote Blower Remove the cover to the Control Box by removing the Phillips screw as shown and sliding the cover - Depending on the type of blower you purchased, down.
  • Page 13: Install Ductwork

    Installation Install Ductwork Re-attach Transition Duct The Transition Base must be installed with the flange at the top. Position the duct Transition Cover on the Transition Base for the discharge direction selected. The top edge of the duct Transition Cover must be under the tabs of the Transition Base.
  • Page 14 Installation Calculating Duct Length Table For maximum efficiency, use the shortest and straightest duct possible. The system will operate most efficiently when the ductwork does not exceed 60 feet of equivalent duct. The downdraft will operate properly with ductwork up to 100 equivalent feet of duct. Calculations are approximate and based on HVAC industry standards.
  • Page 15: Use & Care

    Use & Care Operating the Telescoping Downdraft System - Raise the downdraft by pressing the raise/lower - The blower can also be turned off by simply push button. The telescoping vent will rise up to full pressing the raise/lower push button and lowering height.
  • Page 16 Use & Care Cleaning the Telescoping Cleaning the Telescoping Vent Downdraft Vent - Clean the stainless steel and plastic controls with a dishcloth and hot soapy water. - Rinse with a dishcloth and clean water. - Wring excess water from the dishcloth when It is advised to disconnect power from the downdraft cleaning or rinse.
  • Page 17: Solution To Common Problems

    Solutions to Common Problems Before you call Problem Solution Telescoping Vent - Check for and remove obstructions. The telescoping vent is designed to tilt and does not fully stop with obstructions. The raise/lower push button will reverse direction of travel raise and reset the telescoping vent travel.
  • Page 18 Warranty Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will repair or replace any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions.

This manual is also suitable for:

Ei36dd10ks

Table of Contents