46/60

Operation

Bosch Rexroth AG, A10VO, A10VSO, A10VSNO Series 32, RE 92714-01-B/04.2018
9 Operation
This product is a component which requires no settings or changes during operation.
For this reason, this chapter of the manual does not contain any information on
adjustment options. Use the product only within the performance range specified in
the technical data. The machine/system manufacturer is responsible for the proper
project planning of the hydraulic system and its control.

10 Maintenance and repair

Overdue inspection and maintenance work!
Risk of property damage!
Perform the specified inspection and maintenance work at the intervals
described in this manual.

10.1 Cleaning and care

Damage to seals and electrical system due to mechanical effects!
The jet of a high-pressure cleaner may damage the seals and electrical system of
the axial piston unit!
Do not point a high-pressure cleaner at sensitive components, e.g., shaft seal,
electrical connections and components.
For cleaning and care of the axial piston unit, observe the following:
Check whether all seals and plug-in connections are securely seated to ensure no
moisture can penetrate into the axial piston unit during cleaning.
Use only water and, if necessary, a mild cleaning agent to clean the axial piston
unit. Never use solvents or corrosive cleaning agents.
Remove major external contamination and keep clean sensitive and important
components, such as solenoids, valves, displays and sensors.
NOTICE
NOTICE