GE UNC15NPRCII Owner's Manual And Installation Instructions page 23

Table of Contents

Advertisement

Available languages

Available languages

Drain Pump Kit UPK4 Accessory Installation (Cont.)
6
CONNECT DRAIN PUMP TO ICE
MACHINE (Cont.)
Locate the male
4-pin white pressure
sensor connector
behind the bracket
hole, loosen the
wire tie and connect
the pig tail to the
pressure sensor
located on the drain
male 4-pin white pressure
sensor connector is not
showing in the access
opening area, locate the
connector in the nearby
machine compartment
area and connect it to pressure sensor on the
drain tube assembly. The 4- pin male connector
within the ice machine will match up with the
4-pin female connector on the pressure sensor.
NOTE: the yellow connector within the ice
machine should not be used.
Lower the pump and make
sure the drain tube is not in
Attach the pressure sensor assembly in the 3
holes of the flange of the ice machine, as shown,
using the screw provided with the kit.
Thread the drain hose into the round hole in the
back of the ice machine case and attach to the
large metal clamp.
49-1000610 Rev. 3
Installation Instructions
Pressure Switch
Pump
Pressure Sensor
Connector from
White pressure sensor
connector is tied behind
the flange.
Pressure Switch Assembly
Screw
Large Metal Clamp
6
CONNECT DRAIN PUMP TO ICE
MACHINE (Cont.)
IMPORTANT
the machine cabinet using the green ground wire
and screw. The grounding hole is marked with a
grounding symbol.
7
CHECK PUMP OPERATION
(DO NOT SKIP THIS STEP)
Restore power to the unit.
Pour several quarts of water
into the bin, the drain pump
should turn on and pump
the water out of the bin
automatically, cycling on and
off several times during the
process is normal. Check the
connections if pump had no
response.
While the pump is discharging
FOR LEAKS.
8
FINALIZE INSTALLATION
Re-install side panel using the screws removed
in step 1.
Re-install unit into built-in or free-standing
Restore potable water supply and restart the
unit. Check unit to ensure proper operation and
to allow a final check for leaks of any kind.
Ground the pump to
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Unc15npUnc15npwiiUnc15nprbii

Table of Contents