2. RECORD
AMPLIFIER
BIAS OSCILLATOR
CHECK
(Refer to Fig. 34)
R/P
HEAD
Frequency Counter
Figure 34
Set Mode Selector Switch
(SW-8) at "CASSETTE
PLAY".
Set the unit at RECORD
mode.
Shift R.LF. Switch (SW-4) to "A".
Connect V.T.V.M. to Test Point (R5, R6).
Adjust Semi-variable resistor (R409, R410) so that VTVM's reading becomes 50mV.
Adjust Oscillator Coil (L401) so that the frequency counter's reading becomes 53.5kHz+1.5kHz.
After checking bias frequency, re-check for the item 5.
Then shift R.I.F. switch (SW-4) to "B" and check that bias frequency becomes 52.25kHz+10%.