Download Print this page

Pioneer CT-1060W Service Manual page 27

Stereo double cassette tape deck

Advertisement

Available languages

Available languages

CT-1IO6OW,
CT-S77W
Deck II
1. Head Azimuth Adjustment
@ Turn V102 and V202 to mechanical center positions.
Mode
Input signal & test tape
Adjustment location
Adjustment value
Remarks
STOP
Set the TAPE
SELECTOR switch to the NORM position.
PLAY
Play the 10kHz/—20dB section
Head azimuth adjust-
{Left and right OUT-
|Maximum playback
of the STD-331B
test tape.
ment screw.
PUT terminals.
signal level.
(See Fig. 10-5)
n"
TOP
Lock the screw with screw lock after completing the adjustment.
2. Playback Equalizer Check
lode
Input signal & test tape
Adjustment location
Adjustment value
TOP
Set the TAPE
SELECTOR
switch to the NORM position.
Bi
i)
By > <
Play the 315Hz/~20dB and
Confirm
6.3kHz/-20dB section of
Left and right OUT-
PUT terminals.
The 6.3kH2z playback
level is 0+2dB
against 315Hz level.
the STD-331B test tape.
3. Playback Time Constant Switching Check
e Put the deck into playback mode with no cassette loaded.
@
Check that the noise level changes at the line playback output terminals when the TAPE
SELECTOR
switch is changed.
4. Playback Level Adjustment
@ This adjustment determines the DOLBY
NR level, and must be performed with great care.
Mode
Input signal & test tape
Adjustment location
Measuring location
Adjustment value
Remarks
STOP
Set the TAPE
SELECTOR
switch to the NORM position.
PLAY
| Paly the 315Hz/OdB section of | V102 (Left channel)
TP1 (L ch)
-7.7dBv (412.1mV)
the STD-331B
test tape.
V202 (Right channel)
TP2 (R ch)
. Level Meter Check
REC-
Apply a 315Hz/-10dBv
REC
LEVEL control
TP1 (L ch)
Check that the level meters '"'OdB"' light up
PAUSE
(316mV) signal to the LINE
TP2 (R ch)
within -7.7dBv+2dB of the signal ou tput
INPUT terminals.
level.
6. Recording and Playback Frequency Response Adjustment
Mode
Input signal & test tape
Adjustment location
Adjustment value
STOP
Set the TAPE SELECTOR switch to the NORM position.
aa
REC.
Apply a 315H/-30dBv
REC
LEVEL control
TP1 (L ch)
-27,7dB (41.2mV)
PAUSE | (31.6mV) signal to the LINE
TP2 (R ch)
INPUT terminals.
3]
REC/
Record the above signal level
V104 (Left channel)
|Left and right OUT-
| The 6.3kHz playback level is +0.5 ve dB
PLAY | onto the STD-6GO8A test tape
V204 (Right channel)
|PUT terminals.
against 315Hz level (Playback the sig mals
at 315Hz and 6.3kHz, and
on the STD-608A)
playback.
Change the test tape, tape selector and DOLBY
NR switch positions, and check that the frequency response is satisfact ory
(See Fig. 10-8). If the response does not lie within the specified range, readjust V104 and V204 that the 6.3kHz playmek level
is -2 ~ +3.5dB against 315Hz level in the step 3.
a ae
ee
37

Advertisement

loading

This manual is also suitable for:

Ct-1060w(bk)Ct-s77wCt-s77w(bk)