• The address display time and method can differ by the indoor unit type.
Installer Setting Code Table
Function
Mode override
Ceiling height
selection
Group control
Auxiliary heater
NOTE
• Mode override
- This function is only for non-auto changeover H/P model.
• Ceiling height selection
- Indoor unit connected to wired remote controller operate as wired remote controller setting.
• Group control
- This function is only for group control. Don't set this function in case of non-group control.
After setting group control of the product, turn off the power then turn it back on after 1 minute.
• Auxiliary heater
- This function is only applied to models with auxiliary heater function being activated.
Function Code
0: Set to master
0
1: Set to slave
1: Standard
2: Low
1
3: High
4: Super high
0: Set to master
2
1: Set to slave
2: Check master/slave
3: Set to auxiliary heater
4: Cancel auxiliary heater
2
5: Check auxiliary heater
installation
AFTER INSTALLATION
Setting Value
29
Remote Controller
LCD
O.O
O.1
1.1
1.z
1.3
1.4
z.O
z.1
z.z
z.3
z.4
z.s