Electrical Heater
11.2 Model PAW-VP380L
11.2.1 Installation of the Heating Unit
11
94
For the above mentioned heating or cooling tank, the electrical auxiliary heater is an optional
component and must be ordered separately.
It can be useful, for example, when particularly low outside temperatures are expected or to
compensate for maintenance interruptions.
Heater for
PAW-VP380L
How to Mount the Heating Unit
Proceed as follows:
1. Screw the heating unit (A) into the unit seat (ensure the appropriate tightness of
the connection)
2. Unscrew the upper part of the box (B)
3. Connect the supplying cables to appropriate power connections situated in the up-
per part of the box (B) in accordance with the diagram for connecting three or one
phase heaters (see item 11.2.2 „Electrical Connection" on page 95).
4. Assemble the upper part of the box with the rest of the heating unit
Voltage
400 V (L1 / L2 / L3 / N /PE / 50Hz)
A
PAW-VP•LDHW - Technical Manual – 2020-07
Capacity
6 kW
B