Simon XTi Installation Guide
Content
Contact information ................................................................................ 1
Description ................................................................................................... 1
Installation.................................................................................................... 1
Wiring phone lines.................................................................................... 3
Programming.............................................................................................. 4
Sensors ......................................................................................................... 7
Disposal ......................................................................................................... 9
Specifications........................................................................................... 10
Contact information
www.utcfireandsecurity.com
For customer support, see
www.interlogix.com/customer-support
GE and the GE monogram are trademarks of the General Electric
Company and are under license to UTC Fire & Security, 9 Farm
Springs Road, Farmington, CT 06034-4065
Copyright © 2012 UTC Fire & Security. All rights reserved.
Description
This is the Installation Guide for the Simon XTi system (models 600-
1054-95R-12 and 600-1054-95R-12-CN).
Table 1: Sensors and recommended sensor groups
Device
Part number
Indoor motion sensor
60-639-95R, 60-807-95
Entry/exit door
60-362N-10-319.5
Interior door
60-362N-10-319.5
Door/Window sensor
60-362N-10-319.5
Smoke sensor
TX-6010-01-1
Glassbreak sensor
60-873-95
or
www.interlogix.com
Recommended
sensor group
15, 17, 18, 20, 28, or
b
32
10
14
13
26
c
13
b
Device
Part number
4-Button Key fob
600-1064-95R
Simon XT Talking Touch
60-924-3-XT-2WTTS
Screen
60-924-RF-TS
Simon XT Talking
60-924-3-XT
Touchpad
Carbon Monoxide alarm
TX-6310-01-1
6520-95
a.
Not certified as a primary protection circuit for UL-listed systems
and is for supplementary use only.
b.
Has not been investigated by UL.
c.
Required for UL-listed residential fire alarm applications.
d.
The TWTTS has been verified for use by ETL. Neither this device
nor other devices that employ the UTCFS 80 Bit Enhanced
Protocol have been investigated for use by UL.
Note: These sensor groups are only recommendations. The installer should
choose the correct sensor group for the application.
Caution:
Do not use outdoor motion sensors for intrusion
protection.
Installation
Panel location
Locate the panel where alarm sounds can be heard and where
the panel will be easily accessible for operation. Do not install the
panel near a window or door where it can be reached easily by an
intruder.
Recommended
sensor group
01
b
00, 01, 04, 05, 06, or
b
07
d
01
b
, 600-
34
b
b